PORT ABLE AIR CONDITIONER AMC 7KE-410 10KE-410 12KE-410 GB Portable air conditioner.
2 1. Control panel 2. Air outlet 3. Handle 4. C asters 5. Air filter 6. Air inlet 7. Exhaust air outlet 8. C ord hanger 9. W ater stopper (plug inside) 10. F oam extension 11. F oam with hole 12. W ater tray 13. Hose adapter 14. Window/wall adapter 15.
3 SAFET Y INSTRUC TIONS Thank you for choosing this innovative Amcor air conditioner . W e suggest that you keep this manual in a safe place for future reference.
4 POS I TI ON IN G GB This unit is portable and can easily be moved from one room to another . In doing so keep this in mind: • The air conditioner must stand upright on an even surface. • Position not (near) bath, douche or other wet or damp area.
5 GB • Put the exhaust hose into the round side of the exhaust hose adapter (13) (fig. 1). • Put the wall/window adapter (14) onto the exhaust hose (fig. 2). • C onnect the hose with the rectangular end to the air conditioner (fig. 4). Using the foam.
6 OPER A TION GB 1. ON/OFF Press the ON/OFF-button to switch the unit on or off. The unit selects the operating mode depending on the room temperature: - with an ambient temperature h igher than 23 °C, cooling mode is selected - is the ambient temperature b etween 20 °C and 23 °C, then will fan mode be active.
7 Remote control The air conditioner can be operated with the remote control. T wo AAA- batteries are required to use the remote control. Point the remote control hand set towards the control panel of the unit and press the relevant button, the red LED on the hand set will flash whenever a button is pressed.
8 GB Switch off the unit and remove the plug from the mains. • Remove the drain knob and the rubber plug. • C onnect the correct water tube onto the water outlet. • Place the other end in a normal drain. • Make sure that the tube is free from twists and bends.
9 GB ST ORA GE See the instructions "Emptying the water container" on page 7. • Drain the condensed water completely . • Clean (or replace) the filter . • Put the unit on a sunny day in fan mode for a couple of hours to ensure that the inside becomes completely dry .
10 GB Model AMC 7KE-410 AMC 10KE-410 AMC 12KE-410 Cooling capacity BTU/h 6500 8300 9600 kW 1.9 2.4 2.8 Mains 220–240 V / 50 Hz / 1Ph Power consumption W 690 830 1030 Current A 3 3.
0 5 2 4 2 1 3 1 9 C M A Hong Kong China Shan Xia Industrial Development Zone, Heng Li T own, Dongguan City , Guangdong Province, China Plant One - Amcor (China) Ltd T el: +86 769 8372 1090 F ax: +86 769 8372 1790 Email: amcorcn@amcorgroup.
.
2 1. Control panel 2. Air outlet 3. Handle 4. C asters GB PA R TS 15 14 11 12 10 13 16 17 5 8 7 9 6 4 1 2 3 5. Air filter 6. Air inlet 7. Exhaust air outlet 8. C ord hanger 9. W ater stopper (plug inside) 10. F oam extension 11. F oam with hole 12. W ater tray 13.
3 SAFET Y INSTRUC TIONS Thank you for choosing this innovative Amcor air conditioner . W e suggest that you keep this manual in a safe place for future reference.
4.
5 POS I TI ON IN G GB This unit is portable and can easily be moved from one room to another . In doing so keep this in mind: • The air conditioner must stand upright on an even surface. • Position not (near) bath, douche or other wet or damp area.
6 ON/OFF and timer function T urn the control [1] to switch the unit on or off. When the unit is on, LED-1 is on. Timer function Use control [1] to set a working time between 1 and 8 hours. The unit switches off when the set time has run down. Mode selection and speed setting Select with control [2] the required operating mode cooling or fan mode.
7 GB When the water container is full, the compressor and the ventilator stop functioning, LED [4] will lit. Switch off the unit and remove the plug from the mains. • Place the water tray flat on the floor under the drain. • Remove the drain knob.
8 Important: how to wire a 13 amp plug The wires in the mains lead on this appliance are coloured in accordance with the following code: G REEN AND Y ELLOW – E ARTH B LUE – N EUTRAL B ROWN – L I.
9 GB Never try to repair or dismantle the air conditioner yourself. Incompetent repairs result in loss of warranty and can endanger the user . Problem C ause Solution The unit does not function Check the plug fuse.
10 Amcor products have a lower than industry norm failure rate, as we have strict quality control in our factory . However we are not 100% perfect and occasionally units can fail. When they do we have a simple returns procedure. All Amcor products are guaranteed for one-year from date of purchase, on a back to base principle.
11 YOUR GUARANTEE DOMESTIC AIR CONDITIONERS If this product is found to be defective as a result of faulty materials or workmanship within one year from date of purchase, it will be repaired or replaced free of charge. This guarantee is subject to the following terms: Amcor Limited.
0 2 3 4 2 1 3 1 9 C M A Hong Kong China Shan Xia Industrial Development Zone, Heng Li T own, Dongguan City , Guangdong Province, China Plant One - Amcor (China) Ltd T el: +86 769 8372 1090 F ax: +86 769 8372 1790 Email: amcorcn@amcorgroup.
デバイスAmcor 12KE-410の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Amcor 12KE-410をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmcor 12KE-410の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Amcor 12KE-410の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Amcor 12KE-410で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Amcor 12KE-410を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmcor 12KE-410の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Amcor 12KE-410に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmcor 12KE-410デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。