It is impor tant that you read these instr uctions before using y our new purchase and we strongl y recom- mend that you k eep them in a safe place for future ref erence .
.
T a ble of Conten ts THANK Y OU ……………………………………………………………………… 2 Ener gy Sa ving Tips ……………………………………………………….
Thank you for pur cha sing an AMCOR P or table A ir C onditioner . AMCOR is a le a ding br an d in indoor air treat ment . W e woul d like y ou to enjoy the many benefit s this unit of f er s, so please read this manual c ar efully and t ak e full advant ag e of the m an y advanced features that your AMCOR P or t able Air Conditioner of fers you.
3 S peci fic ation s Model PCMB-12000E PCMB-12000EH Cooling Capacity 1 2 ,0 0 0 BTU / hr 1 2 ,0 0 0 BTU / hr Cooling P ow er Consumption 1,100 W / 9.8 A 1,100 W / 9.8A Heating Capacity N / A 4,0 0 0 BTU / hr Heating P ow er Consumption N / A 1,150 W / 9.
4 Befo r e Use IM PORT ANT! • Le a ve the unit in an upright position for at least 2 hours be for e use. • Al wa ys place the unit on an ev en sur face. • The power c ord has a built-in L .C .D.I. ( Leakage Current Detec tion and Interrupt i on ) circuit break er for added safet y .
5 The P CMB U ni t Ai r Out let Con trol P anel Car ry ing H andle Ca stor W hee ls Pa r t s ON/OF F UP FA N DOW N Remo te Con trol E xhau st Ho se Dr ain P an In sulat ion St rip Sl ide B ar Conn ect.
6 Put spir al water pipe into hot air flexible hose. Connect t he female hal f of the quick connector at the end of the spiral w a ter pipe to the m ale part in the hot air outlet pipe . T u rn t he connector 90 de gr ees clock wise until it is locked in place.
7 Aut oD rain N anoM is t T ec hnol o g y TM As semb ly In sta llat ion of t he W indow Kit In order for t his unit to funct ion properly , it must be vented to t he outside . Fit ting the E xhaust Hose through a window is easy . Please see below . Adjustable Slide Bar Exhaust Hose Slide Bar Connector Window Kit In stallat ion : 1 .
8 In sta llat ion W A RNI NG ! The leng th of the ex haust pipe is specially designed accor ding to the spe cification of this product . Do not exte n d it wit h y our own hos e , as this could cause.
O peration 9 IM PORT ANT: T he air cond itioner should be lef t in an up right position for at lea st two hours A . T u rning the Unit On : 1 . Plug the unit into a working elec trical outle t. 2 . Make sur e the green light on t he plug is on. ( If not , press t h e Reset but ton.
1 0 O peration Timer The TIM ER function allows y ou to progra m the time the unit turns on and turns of f. T O S ET THE TIME R : • Press the TIM E but ton briefly , the 2 hour digits will fla sh. • Press the U P or DO WN but ton to adjust the hour .
1 1 O peration The unit will oper a te d ai ly accor ding to t he timer setting , unless changed. Af ter a pow er f ai lure, or af ter the unit h as been unplug ged, you will ha ve to pro gr am the timer set tings ag ain. Canceli n g the Timer S ett in g In order to cancel t he timer pro gr amming pr ess t he TIME but ton.
1 2 Remote Cont r ol 10:09 72 F ϒ ON/OFF UP FAN DOWN TIME SLEEP MODE SWING fig.1 Slide Cov er Down T o O perate the Re mote Control : Inser t bat teries by pullin g down on front co ver ( See fig. 1 ) . Be sure the remote is pointed at t he un it at all times .
1 3 E mptyi n g t he Inter nal W ater Contai ner Note : There are t w o inst anc es w h ere dr a ining the inte rnal water cont ain er m a y be recommended : 1 . In the unlik ely event that t he C ont ainer Full Light on the L CD display flashe s 2 .
Always unplug t he unit from the wa ll before per forming any maintenance . • M ak e sure the unit is drained be fo re moving . Clea nin g t he Unit : • O nly use a so f t damp clot h. • N e ver use chemicals, oil -based product s, deterge nts, or other c leaning solutions.
Tr ou bles hooti n g I f you ha ve any questions rega rdin g t he operation of t he this produc t plea se contact A MCOR at 1 - 866 - 3 6 1- 223 3 RE P L A CE ME NT FIL TE RS : T o purch ase Repl acem.
Don’t forget to re gist er y our Amcor purch ase online , and v ie w our broad se lection of innovative products . w w w . amcorgroupus a . com 1 6.
.
One Y ea r Limited W arr ant y ( 5 Y ea rs for Compressor Only ) Amcor , Inc. ( “ A mc or” ) warrant s the original r et ail purchaser ( “Purcha ser” ) pur cha sin g in the United St a tes t hat the Amcor pr oduc t with which this warr anty is enclosed is free fr om defec ts in mater ials and wo rk manship.
デバイスAmcor PCMB-12000Eの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Amcor PCMB-12000Eをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmcor PCMB-12000Eの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Amcor PCMB-12000Eの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Amcor PCMB-12000Eで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Amcor PCMB-12000Eを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmcor PCMB-12000Eの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。