Instructions–Parts List Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. 15:1 Fire-Ball R 300 Pumps For pumping petroleum–based undercoating material. 2700 psi (18.6 MPa, 186 bar) Maximum Working Pressure 180 psi (1.
2 306531Z1 Symbols Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions. W arning Symbol W ARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.
306531Z1 3 W ARNING SKIN INJECTION HAZARD Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury .
4 306531Z1 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 7.
306531Z1 5 Notes.
6 306531Z1 Installation Fig. 1 KEY A Electrically C onductive Air Hose B Female Quick Disconnect Coupler C Male Quick Disconnect Fitting D Air Line Filter E Air Regulator and Gauge F Bleed-T ype M ast.
306531Z1 7 Installation CAUTION Provide a bracket for mounting the air accessories. The fittings are not strong enough to support the accessories and may cause one or more to break.
8 306531Z1 Operation Pressure Relief Procedure W ARNING SKIN INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally . Fluid under high pressure can be injected through the skin and cause serious injury .
306531Z1 9 Notes.
10 306531Z1 Maintenance Shutdown and General Care W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. D Always relieve the pressure when you shut down the pump.
306531Z1 11 Maintenance Packing Nut Adjustment W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. W ARNING Keep your hand and fingers away from the piston when it is moving.
12 306531Z1 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
306531Z1 13 Air Motor Service Before you start: D Have all necessary parts on hand. Always replace the glands and bearing when replacing the pack- ings. Use all the parts in the repair kits for the best results. See page 18 to order the kits. D Air Motor Repair Kit 206728.
14 306531Z1 Air Motor Service Fig. 7 M 28 54 34 † 33 † 45 † 33 † 45 † 59 55 30 37 32 † L 53 † 58 31 041 18 1 1 T o remove toggles: push in, swing up, ease out. Push toggles (M) in and then up (shown in down position). 2 3 2 T urn wires up.
306531Z1 15 Air Motor Service 6. Install the bottom adjusting nuts (33) on the poppet valve stems (45 † ) and screw the stems into the grommets (32 † ). Screw the top nuts (33 † ) on the stems. Before installing the lockwires (34 † ) in the adjusting nuts, use the gauge 171818 to adjust the transfer valve so there is 0.
16 306531Z1 Displacement Pump Service Before you start: 1. Have all necessary parts on hand. Whenever you replace the packings, also replace the glands and bearing. If you are using a repair kit, use all the parts for the best results. See the parts pages to order the kits.
306531Z1 17 Displacement Pump Service NOTE: If the pressure-fit brass bearing (15*) needs to be replaced, clamp it in a vise and drive the piston body (13) out with a plastic hammer . The new bearing must be started onto the piston body squarely . 8. Clean and inspect the parts and replace any that are worn or damaged.
18 306531Z1 Parts 10 14 2* 19* 6* 18* 17* 12 3* 22 21 13 15* 47 27 51 35 29 37 31 30 28 34 † 33 † 32 † 33 † 54 57 58 † 36 59 45 † 41 *4 38 55 20 24 60 63 25 40 *4 53 † 39 † 42 44* 43 50* 48* 49* 16* 46 7* † 04213B Model 206405, Series K 35 lb.
306531Z1 19 Parts Model 206405, Series K 35 lb. pail size Ref No. Part N o. Description Qty . Ref No. Part No. Description Qty . 2* 1001 14 BALL, steel, 0.44” (1 1.2 mm) dia. 1 3* 100400 BALL, steel, 0.75” (19 mm) dia. 1 4* 101579 PIN, roll, 0.12” (3.
20 306531Z1 Parts Model 206699, Series J 120 lb. drum size Model 206700, Series J 400 lb. drum size 10 14 2* 19* 6* 18* 17* 12 3* 22 21 13 15* 27 51 35 29 37 31 30 28 34 † 33 † 32 † 33 † 54 57.
306531Z1 21 Parts Model 206699, Series J 120 lb. drum size Model 206700, Series J 400 lb. drum size Ref. No. Part N o. Description Qty . Ref. No. Part No. Description Qty . 2* 1001 14 BALL, steel, 0.44” (1 1.2 mm) dia. 1 3* 100400 BALL, steel, 0.75” (19 mm) dia.
22 306531Z1 Notes.
306531Z1 23 Dimensions 04217B 1/4 npt(f) Fluid Outlet Model 206405 13 inches (330 mm) Model 206699 26.69 inches (677.7 mm) Model 206700 33.62 inches (854 mm) 3/8 npt(f) Air Inlet T echnical Data Maximum W orking Pressure 2700 psi (186 bar) . . . . . .
24 306531Z1 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
デバイスGraco 206405の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 206405をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 206405の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 206405の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 206405で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 206405を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 206405の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 206405に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 206405デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。