Instructions–Parts List Monark r Air Motor For use with Graco fluid handling pumps. 180 psi (1.2 MPa, 12 bar) Maximum Air Working Pressure Model 206955, Series K For ST ANCHION TUBE mounting Model 2.
2 307043 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air Motor Service 6 . . . . . . . . . . . . . .
3 307043 W ARNING SKIN INJECTION HAZARD Spray from the gun/dispensing valve, leaks or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury .
4 307043 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
5 307043 Installation Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below . Also read the section FIRE AND EXPLOSION HAZARD on page 4. Proper grounding is an essential part of maintaining a safe system.
6 307043 Air Motor Service Pressure Relief Procedure W ARNING SKIN INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying/dispensing acciden- tally . Fluid under high pressure can be injected through the skin and cause serious injury .
7 307043 Air Motor Service 7. Pull the piston assembly (G) from the air motor base (F), and set it aside. 8. Remove the bearing housing assembly (26 or 27) for all Models except Model 206955. Remove and wipe the seat clean with a cloth. For model 206955, remove retainer ring (3) and bearing (4).
8 307043 Air Motor Service 13. Straighten the lockwires (L*) and remove them from the upper valve nuts (J*). Screw the upper valve nuts off. Remove the trip rod yoke (O), actuator (V), and trip rod (C). 14. Unscrew the bottom valve nuts (K*), and remove the poppets (N*).
9 307043 Air Motor Service 6. Install the toggle pins (Z) in the yoke (O). As- semble the toggle assembly (U) by placing a well greased spring onto the toggle arm (T) and then the toggle rocker (S).
6 *12 13 9* 10* 11 n 31 n 14 *15 2 21 20 5 18 32 34 33 05704 n 3 n 7 25 24* 8* 9* 1 22 30 4 23* 17 19 Y 36 35 28 29 n 27 NOTE: Seal lips face upward 26 10 307043 Parts HINGED CLAMP MOUNTING: SANIT AR .
11 307043 Parts HINGED CLAMP MOUNTING: SANIT AR Y Model 207546, Series H , Air Motor Assembly Includes items 1–36 Ref. No. Part No. Description Qty . Ref. No. Part No. Description Qty . 1 1 14422 SCREW , phillips hd mach; no. 8–32 x 0.375 in. (10 mm) long.
05705B 10 *16 17 13* 14* 15 n 30 n 18 20 24 25 9 21 31 33 32 n 7 n 11 29 28* 12* 13* 1 Y 37 *19 8 27* 23 26 35 34 NOTE: Seal lips face upward 3 4 n 2 5 36 6 12 307043 Parts ST ANCHION TUBE MOUNTING Mo.
13 307043 Parts ST ANCHION TUBE MOUNTING Model 206955, Series K, Air Motor Assembly Includes items 1–37 Ref. No. Part No. Description Qty . Ref. No. Part No.
05706B n 7 *12 13 9* 10* 11 n 31 n 14 *15 3 46,18 36 6 22, 37 32 34 33 n 4 n 19 26 25* 8* 9* 1 Y 43 5 24* 17 23 40 39 29 30 n 28 NOTE: Seal lips face upward 27 21 20, 38, 44 2 14 307043 Parts Model 20.
15 307043 Parts Model 205997, Series K Air Motor Assembly Includes: 1, 3–19, 23, 25–34, 36–43 Model 215363, Series D Air Motor Assembly Includes: 1, 3–19, 21, 23, 25–34, 37–43 Model 222791, Series D Air Motor Assembly Includes: 1–23, 25–34, 39–43 Ref.
16 307043 Accessories BLEED-TYPE MASTER AIR V AL VE (REQUIRED) 300 psi (21 bar , 2.1 MPa) Maximum Working Pressure Relieves air trapped in the air line between the pump air inlet and this valve when closed.
17 307043 Dimensional Drawings 05709 1 1.75 in. (298.4 mm) 13.25 in. (336.6 mm) 15.75 in. (400.1 mm) for 206955 5.75 in. (146.1 mm) Mounting Hole Layouts Three 0.34 in. (8.6 mm) diameter holes on 6.38 in. (162.1 mm) bolt circle 3 T ie Rod Pumps 05707 05708 45_ 45_ 2.
18 307043 Graco Standard W arranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from de fec ts in material and workmanship on the date of sale to the original purchaser for use.
デバイスGraco 207546の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 207546をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 207546の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 207546の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 207546で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 207546を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 207546の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 207546に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 207546デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。