Instructions – Parts List GRACO INC. P .O. BOX 1441 MINNEAPOLIS, MN 55440–1441 Copyright 1989, Graco Inc. is registered to I.S. EN ISO 9001 2:1 Ratio Monark R Pump 200 psi (1.4 MPa, 14 bar) Maximum Fluid Working Pressure 100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure Part No.
2 307985 Symbols W arning Symbol W ARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
307985 3 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
4 307985 Notes.
307985 5 Installation General Information NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor .
6 307985 Installation 06089 Fig. 2 KEY A Bleed-T ype Master Air V alve (required, for pump) B Air Filter/Regulator C Air Line Lubricator D Fluid Drain V alve (required) E Surge T a nk F Fluid Shutoff .
307985 7 Installation A vailable Accessories (must be purchased separately) Air Line Accessories W ARNING A bleed-type master air valve (A) is required in your system to help reduce the risk of serious injury , including splashing of fluid in the eyes or on the skin, and injury from moving parts if you are adjust- ing or repairing the pump.
8 307985 Operation Pressure Relief Procedure W ARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally .
307985 9 Operation Prime the Pump 1. See Fig. 2. Remove the spray nozzle from the gun. See the gun instruction manual. 2. Close all bleed-type air valves (A, N). 3. Close the pump air filter/regulator (B). 4. Close the fluid drain valve (D). 5. Check that all fittings throughout the system are tightened securely .
10 307985 Notes.
307985 1 1 Maintenance Shutdown and Care of the Pump W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
12 307985 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Relieve the pressure. 2. Check all possible problems and solutions before disassembling pump.
307985 13 Service Disconnecting the Displacement Pump NOTE: For displacement pump repair instructions, refer to the separate displacement pump manual 307983, supplied. W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
14 307985 Parts Model 223185, Series C 2:1 Ratio Monark Pump, 55 Gallon (200 Liter) Drum Size; UHMWPE and Leather Packed Ref Part No. No. Description Qty 1 206955 AIR MOTOR, Monark See 307043 for parts 1 3 223177 PUMP , displacement; used on Model 223185 See 307983 for parts 1 4 19161 1 ROD, connecting; 19.
307985 15 Parts Model 223186, Series C 2:1 Ratio Monark Pump, Stubby Size; UHMWPE and Leather Packed Ref Part No. No. Description Qty 1 206955 AIR MOTOR, Monark See 307043 for parts 1 3 223177 PUMP , displacement; used on Model 223186 See 307983 for parts 1 4 191736 ROD, connecting; 6.
16 307985 Dimensions 06085 A B C Model No. A B C 223185 47.81 in. (1215 mm) 15.31 in. (389 mm) 32.5 in. (826 mm) 223186 35.31 in. (897 mm) 15.31 in. (389 mm) 20 in. (508 mm) Mounting Hole Layout 2.254 in. (57.25 mm) 5.250 in. (133.4 mm) 0.375 in. (9.52 mm) diameter 2.
307985 17 T echnical Data Category Data Ratio 2:1 Maximum fluid working pressure 200 psi (14 bar) Maximum air input pressure 100 psi (7 bar) Pump cycles per 1 gallon (3.8 liters) 11 Fluid flow at 60 cycles per minute 5.5 gpm (21 liters/min) Fluid inlet size 1–1/2 npt(f) Fluid outlet size 1 in.
18 307985 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
デバイスGraco 223185 Series Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 223185 Series Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 223185 Series Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 223185 Series Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 223185 Series Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 223185 Series Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 223185 Series Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 223185 Series Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 223185 Series Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。