Gracoメーカー247706の使用説明書/サービス説明書
ページ先へ移動 of 22
312349G Instr uctions , Repair and P ar ts 10:1 Dyna-Star ® Pump Module Pro vides lubricant flo w and pressure to operate a single line parallel automatic lubrication system.
Warnings 2 312349G Wa r n i n g s The f ollowing w arnings are for the set up , use, groun ding, maintenance , and repair of this equipment. The e xclama- tion point symbol alerts you to a gener al warning and the hazard symbol ref ers to procedure-specif ic risk.
Warnings 312349G 3 PRESSURIZED EQUIPMENT HAZARD Fluid from the gun/dispense v alve , leaks, or ruptured components can splash in t he ey es or on skin and cause serious injury . • F ollow Pressure Relief Procedure in this manual, w hen you stop spra ying and before cleaning, chec king, or ser vicing equipment.
Unpacking 4 312349G Unpac king The Dyna-Star pump mod ule was carefully pac kaged f or shipment b y Graco . When the pac kage arriv es, perf or m the f ollowing pro cedure to unpac k the units: 1. Inspect the shipping bo x carefully f or shipping damage .
Pump Module Assembly 312349G 5 Pump Module Assembl y Models 247706 and 247707 only F or divider v alve-based au tomatic lubrication systems. (Unless otherw ise indicated, see F IG . 1). 1. Install Pump (D ) on Reser voir (P). 2. Remov e V ent V alve Hydraulic Control (J) fitting and replace with Plug (R) (F IG .
Installation 6 312349G Installation Read instruction man ual 312350 BEFORE installing this product. Gr ounding (for non-mobile installation) (See F IG . 3 belo w) 1. Loosen g rounding lug loc knut (A) a nd washer (B). 2. Insert one end of a 12 gage (1.
Installation 312349G 7 Hydraulic Control Module f or Custom T ank Installation (Unless otherwise indicated, see F IG . 5 and F IG . 6, page 9) 1. Mount con trol module on a flat, st urdy surface per the recommended configurat ion (Fig. 2, pag e 8). 2.
Installation 8 312349G T ypical Installation The installation shown in Figures 4, 5, 6 and 7 are only a guide for se lec ting and installing system components.
Installation 312349G 9 V ent V alve Installation Kit F IG . 5 Key: A Hydrau lic control line B V ent valv e C Pump output connection lin e D Pressure relief v alve E Lubricant outpu t F V ent line Control Module Installation Kit F IG .
Installation 10 312349G Custom T ank Installation F IG . 7 Vent return port 1/2-inch n pt (f) Vent valve bracket w eld locations Pump mounting Ø.343 or 5/16 -18 (4x) Control modu le Ø.
Operation 312349G 11 Operation Pressure Relief Pr ocedure Models 247444, 247574, 247456, 247457, 247970 (See F IG . 4, page 8. ) 1. Disable h ydr aulic supply to Pump (D) by isolating it from the high pressure hydr aulic supply using Ball Va l v e ( A A ) .
Operation 12 312349G Fill Reservo ir (F or these instructions see F IG . 4, page 8.) 1. Connect lubricant supply hose from remote filling station pump to Fill P or t (K). 2. Connect High Pressu re Lubricant Supply Line (G) to V ent V alve (U) outlet. 3.
Service 312349G 13 Service Use only Gen uine Gr aco Repair Pa r ts. See separate s ystem compon ent manuals for ser vice instructions. F or pump service see manual 312350 . Fo r v ent valv e service see manual 309099. T r oub leshooting Prob lem Cause Solution System does not b uild sufficient pressure.
Parts Drawing 14 312349G Pa r t s D r a w i n g (See P arts List, page 17) Pump hydraulic outlet Pump lubricant outlet Pump hydraul ic inlet 1a or 1b 3j 3l 3k 3i 3d 3a 3g 3c 3f 3h 3e ti10644a.
Parts Drawing 312349G 15 Pa r t s D r a w i n g V ent V alve Kit (2): 237170 Contr ol Module Kit (4): 247538 (See P arts List, page 17) T o pump hydraulic inlet To p u m p To p u m p lubri cant outlet.
Parts Drawing 16 312349G Pa r t s D r a w i n g Pressure Relief Kit (5): 247902 (for models 24770 6 and 247707 onl y) ( See P arts List, page 17 ) 5g 5f 5e 5d 5j 5c 5h 5b 5a ti11458a.
Parts Li st 312349G 17 Pa r t s L i s t Model 247706: Dyna-Star 10 :1 Pump Module, 60# for Single Line, Progres sive, Automatic Lubrica tion Systems (inc ludes items 1a , 3, 4, 5) Model 247707: Dyna-S.
Technica l Data 18 312349G T e c hnical Data Maximum h ydrau lic input pressure 3500 psi (24.0 MP a, 240 bar) Pump wetted par ts see manual 312350 V ent v alve w etted par ts see manual 3090 99 Reser voir wetted par ts steel, buna-n r ubber Maximum deliv ery @ 60 cpm 1.
Dimensions 312349G 19 Dimensions Overflo w por t 1/2 inch npt Mounting Dia gram ø 15.0 inch (381 mm) 6- 7/16 inch holes 13 7/8 inch bolt circle Fill por t 1/2 inch npt 15.
Dimensions 20 312349G Dimensions Overflo w por t 1/2 inch npt Mounting Dia gram ø 15.0 inch (381 mm) 6- 7/16 inch holes 13 7/8 inch bolt circle Fill por t 1/2 inch npt 15.
Dimensions 312349G 21 Notes.
Graco Standard Warra nty 22 312349G Graco Standar d W arranty Graco warrants all equipment ref erenced in th is document which is manuf actured by Graco and bearing its name to be free from de fe c t s in material and workmanship on the date of sale to the origin al purch aser for use.
デバイスGraco 247706の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 247706をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 247706の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 247706の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 247706で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 247706を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 247706の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 247706に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 247706デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。