Instructions For series progressive, oil and grease lubrication. For Professional Use Only. Models/Maximum Pressure Table 1: Maximum Press ure Lube Points Table 2: MGO Series-Flo Divider Max imum Operating Pr essures Important Safety Instructions Read all warnings and instructions in this manual.
Warnings 2 312497P Warnings The following Warnings are fo r the setup, use, grounding, mainte nance and repair of this equipment. Th e exclama- tion point sym bol alerts yo u to a gene ral warning and hazard symbols refe r to proced ure-specific risks.
Setup 312497P 3 Pressure Relief Procedure Follow the Pressure Re lief Procedure whenever you see this symbol. 1. Verify pump feeding valve is stopped an d discon- nected from, or locked ou t of it’s driver. 2. Using a wrench, slowly loosen inlet nut.
Setup 4 312497P Component Identification Key: A Valve Section B Inlet Section C Indicator / Port Plug D Crossport Plate E End Plug F Subplates with Outlet Ports G End Section H Tie Ro d Nut Table 3: T.
Setup 312497P 5 Prefilling Lubricant Distributor Lines Follow the following procedure exactly as written, in the order written. Filling Secondary-t o-Lube Point Lines Refer to F IG . 4. when performing this procedure . 1. Remove port plugs or performance indicators from all of the indicator po rts on front of second ary divider valves.
Setup 6 312497P 4. Continue to stroke the pump until the lubricant purges all the air out of the internal pa ssages of th e secondary divide r valve and lubrican t flows freely from all indicator ports with no evidence of included air.
Repair 312497P 7 Repair General Repair Instructions • Before performing an y repair procedure s, relieve pressure , page 3 . • Pressure test distribution bloc ks yearly or every 8000 hours.
Repair 8 312497P Section 1: Purging Air fr om Secondary Divider Valv e Lube-to-Lube Point Lines Steps 1-6, refer to F IG . 7. 1. Install the line from the secondary divider valve to the lube point, but do not completely tighten the connection at the lube point.
Repair 312497P 9 Section 2: Purging Air fr om Master to Secondary Divider Valve Lube Lines Steps 1- 9, refer to F IG . 8. 1. Install the lines from the master divider valve to the secondary divid er valve, bu t do not co mpletely tighten the connection at the secon dary divider valve’s inlet.
Repair 10 312497P Section 3: Purging Air from Pump to Master Divider Valve Lines Steps 1-3, refer to F IG . 9. 1. Install the line from the system pump to the master divider valve, but do not comple tely tighten the con- nection at the master valve’s lube inlet.
Repair 312497P 11 Section 4: Purging Air After Adding or Replacing a Master Divider Valve Module Steps 1-7, refer to F IG . 10. 1. Install the new or replacement mod ule into the mas- ter divider valve assembly.
Repair 12 312497P Section 5: Purging Air Afte r Adding or Replacing a Seco ndary Divider Valve Module Steps 1-8, refer to F IG . 11. 1. Install the new or replacement mod ule to the sec- ondary divider valve assembly. Also connect the tubing or hoses to the a ppropriate lubrica tion point if the new/replacement module is a base section.
Repair 312497P 13 Locating and Repairing Blockages Blocks will cause a higher than normal pumping pres- sure. Depending on the applicatio n or system design, this blockage will usually re sult in a complete loss of lubricant flow into the tota l system and no bearing will be receiving lubrication.
Repair 14 312497P 4a. Master Divider Valve Equipped With Performance Indicator With manual pump co nnected to the m aster divider valve as outlined in Locating Blockages, Step 3, raise pressure to 2000 psi (14 M Pa, 138 bar). Th e indicators in the indicato r ports will signal the loca- tion of the blockage.
Repair 312497P 15 fitting and slowly operate manual pum p to verify location. If blockage is in this divider valve, go to step 7. 6. Install ma nual pump into each in dicator port o f sec- ondary divid er valve in t urn and slowly operate pump (F IG .
Repair 16 312497P d. Clean section s and piston s in suitable clean sol- vent until all lubricant has been removed. e. Use compressed air to dr y and blow out a ll ports thoroughly . A small metal probe should be used to make sure all passages are clean and open.
MD Series 312497P 17 MD Series Technical Data Parts Dimensions Material Steel Pressure (max) 3,000 psi (20.7 MPA, 206.8 bar) Lubricant Oil or grease Net Weight (approx.) 1-lb. 8 oz (0.68 kg) Volume (Lubricant to cycle divider valve one co m- plete cycle) MD-2, MD-3, MD-4 0.
MJ Series 18 312497P MJ Series Technical Data Dimensions Material Plated Pressure (max) 2,000 psi (13.8 MPa, 137.9 bar) Lubricant Oil or grease up to NLGI Grade 1 Max Operating Temp erature 200°F (93°C) Max Cycle Rate With Cycle Pin 60 CPM Net Weight (approx.
MJ Series 312497P 19 Parts *Component is shipped with gasket Ref Part No. Description 1* 562500 VALVE, assembly, MJ 5S 562501 VALVE, assembly, MJ 10S 562502 VALVE, assembly, MJ 15S 562503 VALVE, assem.
MSP Series 20 312497P MSP Series Technical Data Material Corrosion Pr otected Ste el (optional: Type 303 Sta inless Steel) Pressure (max) Zero Leak Inlet 1500 psi (10.
MSP Series 312497P 21 Dimensions ti11478 CROSSPORT PLAT E (OP TIONAL).
MSP Series 22 312497P Parts Ref Part No. Description 1 562711 VALVE, assembly MSP 05S 562712 VALVE, assembly MSP 10S 562713 VALVE, assembly MSP 15S 562714 VALVE, assembly MSP 20S 562715 VALVE, assembl.
MSP Series 312497P 23 1 3 5 or 6 2 4 8 9 7.
MHH Series 24 312497P MHH Series Technical Data Material Steel Body (corrosion protected) Steel Piston (honed fit) Pressure (max) 7,500 psi (52 MPa, 517 bar) for Petroleum or Synthetic Oil - fluoroela.
MHH Series 312497P 25 Dimensions INDICATOR PORT (TYPICAL) , MOUNTING SCREW (TYPICAL) LUBE INLET .281 (7.137) DIA (4) MTG HOLES 3.000 (76.2) 1.750 (44.4) "A" 2.188 (55.56) 1.656 (42.06) 1.500 (38.1) .781 (19.9) 1.125 (28.58) .406 (10.31) .734 (18.
MHH Series 26 312497P Parts Ref Part No. Description 1 562679 VALVE, assembly MHH 06S 562680 VALVE, assembly MHH 09S 562681 VALVE, assembly MHH 12S 562682 VALVE, assembly MHH 18S 562683 VALVE, assembl.
MXP Series 312497P 27 MXP Series Technical Data Material Zinc Plated Steel Pressure (max) 3,000 psi (20.7 MPa, 206.8 bar) Lubricant Oil or grease Maximum Ope rating Temper ature 350°F (177° C) Maximum Cycle Rate With Cycle Pin 60 CPM Maximum Cycle Rate With out Cycle Pin or With Prox Cycle Switch 200 CPM Net Weight (approx.
MXP Series 28 312497P Dimensions ,5"%).,%4 ).$)#! 4 /20/24 ,5"%/54,%4 /04)/.!, #2/330/240,! 4%/04)/.!, ti11477.
MXP Series 312497P 29 Parts Ref Part No. Description 1 562813 VALVE, twin, .025 MXP 562814 VALVE, twin, .050 MXP 562815 VALVE, twin, .075 MXP 562816 VALVE, twin, .100 MXP 562817 VALVE, twin, .125 MXP 562818 VALVE, twin, .150 MXP 562819 VALVE, single, .
MGO Series 30 312497P MGO Series Technical Data Material Zinc Plated Steel and Phosphate Coated Cast Iron Pressure (max) 3-7 section divider valve assembly 6000 psi (41 MPa, 414 bar) 8 section divider.
MGO Series 312497P 31 Dimensions ).,%4 /54,%43 ).$)#! 4/20/24 3.
MGO Series 32 312497P Parts Ref Part No. Description 1 562570 VALVE, MGO, assembly 150S SAE 562571 VALVE, MGO, assembly 300S SAE 562572 VALVE, MGO, assembly 450S SAE 562573 VALVE, MGO, assembly 600S S.
MX Series 312497P 33 MX Series Technical Data Material Plated Steel Pressure (max) 3,000 psi (21 MPa, 206.8 bar) Lubricant Oil or grease Maximum Operating Temperature 200°F (93 °C) Maximum Cycle Rate With Cycle Pin 60 CPM Maximum Cycle Rate Without Cycle Pin 200 CPM Net Weight (approx.
MX Series 34 312497P Dimensions v /54,%4 ti11476.
MX Series 312497P 35 Parts *Component shipped with gasket Ref Part No. Description 1* 562514 VALVE, MX assembly 25S 562515 VALVE, MX assembly 25T 562516 VALVE, MX assembly 50S 562517 VALVE, MX assembl.
Accessories 36 312497P Accessories Tube Clips Clips are plated and provi ded with 17/64” (6.75 mm) mounting holes. Mounting Bars Mounting Brackets All mounting brackets include screws, lock washers an d nuts.
Accessories 312497P 37 Automatic Relief Indicator Automatic Relief Indicators p inpoint lube line blockag e but a llow the lube system to continue to supply lubrication to points that are not blo cked. They are used p rimarily in seco ndary divide r valves.
Accessories 38 312497P Rupture-to-Atmosphere Indicator Rupture-to-Atmosphere Indicators are standard on all Gr aco pumps. When the pressure r eaches a predetermin ed pressure se tting, the p ressure dis c ruptures, venting lu bricant into the atmosp here and relieving pre ssure.
Accessories 312497P 39 Rupture Discs All discs are 11/16” diame ter. Singling and Crossporting Bar Assemblies Singling Kits externally co nvert a “T” (Twin Ou tl et) section to an “S” (Single Outlet) section. Crossportin g Kits externally co mbine th e output of two (2) ad jacent sections.
Accessories 40 312497P Cycle Counters - Part No.: 563444 The purpose of a cycle counte r is to give assurance that th e lubr icant is flowing thru the system.
Accessories 312497P 41 Proximity Cycle Switches The Proximity Cycle Switches are magnetica lly operated single throw switches that sense the movemen t of the divider valve piston when it is cycling. Each proximity cycle switch provides a signal that is used to monitor the sys- tem.
Accessories 42 312497P Proximity Switch Connection Cables Base Section Sub Assemblies Connection Cables for: 3-Pin Proximity Switch 5-Pin Proximity Switch Connector Length - ft (m) Part No. C onnector Length - ft (m) Part No. Straight 6 (1.83) 558021 Straight 6 (1.
Notes 312497P 43 Notes.
All written and visual data con tained in th is document reflects the latest product in fo rmation available at the time of publica tion. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/pate nts.
デバイスGraco 312497Pの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 312497Pをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 312497Pの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 312497Pの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 312497Pで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 312497Pを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 312497Pの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 312497Pに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 312497Pデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。