Gracoメーカー965477の使用説明書/サービス説明書
ページ先へ移動 of 22
INSTRUCTIONS 684025 Revision E Instructions This manual c ontains im portant warnings and infor mation. READ AND RETAIN FOR REFE RENCE Air-Powered King and Premier Hy dra-Cat ® H.
2 684025 Table of Contents Sy mbols .............................................................................3 Definition of T erm s ............................................................3 W arnings ..........................................
684025 3 Sy mbols Warning Sy mbol Caution Sy mbol WA RNING CA UTION This symbol alerts you to the possibility of serious inj ury or death if you do not follow the instructions This sy mbol aler ts you to the possibility of dam a g e to or destruction of equipm ent if you do not follow the instru ctio ns.
4 684025 WARNING FIRE AND EXPLOSION HAZA R D Impr oper g roundin g , poor ventilation, open flam es, or spark s can c ause a hazardous condition and res ult in fire or ex plosion and serious injury. • Ground the equipm ent and the obj ect being spr ay ed.
684025 5 WARNING INJECTION HA ZA RD Spray from the s pray g un, hose leak s or ruptur ed com ponents can inj ect fluid into your body and caus e extrem ely serious injury, includin g the need for am putation. Splas hin g fluid in the eyes or on the sk in c an also cause s erious injur y.
6 684025 Specifications of Hy dra – Cat H.P. Pumps The f ollowin g chart g ives specif ications for the Hydra-Cat H.P. pumps , usin g No. 10 wei g ht oil. The volum etric ratio is express ed as the proportion of the volum e of fluid of the prim ary pump c om pared to the volum e of f luid of the secondary pump.
684025 7 KEY A Bleeder Ty pe Main Air Valve B Air Regulator C Pressure Relief Valve D Mix Manifold E Air Supply Line F Air Line Filter G Air Shutoff Valve H Air Line Lubricator J Base Supply Pump K Ca.
8 684025 Electr ical Grounding WA RNING 4. Spray gun or dispens ing valv e: Obtain grounding throu g h connection to a properly g rounded fluid hose and pump. FIRE AND EXPLOSION HAZA R D Static electric ity is created by the hi g h velocity flow of f luid throu g h the pump and hos e.
684025 9 Ratio Adjustment Understanding the term s used with the Hydra – Cat (H.P .) System , how it functions, and how to find and set the correct ratios for y our application is the key to easier, m ore versatile operation of your proportional system.
10 684025 Determin e the R atio Set the ratio based on your situation. If : • The fluid s are supplied at a ready – to – spray viscosity , sim ply set the ratio as ex plained under A djusting th e Ratio .
684025 11 Operation WA RNING System Flushing INJE CT ION HA ZA RD The system pr essure m us t be m anually relieved to prevent the system from starting or spray in g accidentally. Fluid under hi g h pressur e can be injec ted through the sk in and cause ser ious injury.
12 684025 Checking the Rati o Note: The mix ratio m ust be c heck ed at the norm al operatin g fluid press ure of the pum p. Most mix er manif olds pr ovide a m eans for chec kin g mi x r a ti o that includes needle valves for adj ustin g the fluid pressur e during the test.
684025 13 A ir Lubrication Make sure to use an Indus trial Grade 1, Heavy Duty , Extrem e Pres sure, Lithium Soap Gr ease, G raco Part Number 110293 or equivalent. Replace the covers (17) and the bolts ( 16) af ter g reasin g , and before startin g the mac hine.
14 684025 Troubleshooting Troubleshooting Techniques Because the pum ps ar e m echanically linked, the action of one pump c an aff ect the readin g s of the s econd pum p. Theref ore, the k ey to successf ul troubleshooting is to be sure to isolat e the probl em.
684025 15 Troubleshooting Chart PROBLEM CA USE SOLUTION Sy stem will not run or stops while running. Air press ure or air volume is too low. Increase air pressur e. Check air com pres sor and air s upply f ilters re g ulator, lubricator valves and other com ponents for block a g es and restric tions.
16 684025 Service Required Tools • Set of large adjus table wrenches • Set of m etric soc kets or wrenches • Large pipe wrenc h • Torque wrench • Rubber mallet • Flat end punc h 4. W ith the bleeder ty pe main air valve turned of f ( 1), rem ove the thumb sc rews (14) and the two g uards (15) fr om the sides of the proportioner.
684025 17 Reconnecting the Di splacement Pump CA UTION 1. Mak e sure the c ouplin g nut (10,11) and the couplin g collars (12) are in place on the displac em ent rod. See Fig. 6. Be sure to use an overhead hoist when lifting, m oving or disconnectin g the ai r motor.
18 684025 Replacing the Beari ngs 1. Relieve the Press ure. Refer to Figure 6 and Figure 7. WA RNING To reduce the risk of serious inj ury w henever you are instruc ted to relieve pres sure, always follow the Pressure Relief Proce dure on page 11.
684025 19 Dimensions (A) Height.......................................... 66.0 inch 1676 m m ) (B) Length .......................................... 31.5 inch (800 m m ) (C) W idth ........................................... 33.0 inc h (838 m m ) (D) Air Inlet.
20 684025 NOTES.
684025 21 Technical Data Air m otor eff ective diam eter ....................................................................................Prem ier 12.64 ” (321 m m ) ................................................................................
22 684025 Graco Standard Warranty WA RRA NTY Graco warrants all equipment manufact ured by it and bearing its name to be f ree f rom defect s in material and workm anship on the date of sale by an authorized Graco dist ributor t o the original purchaser f or use.
デバイスGraco 965477の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco 965477をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco 965477の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco 965477の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco 965477で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco 965477を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco 965477の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco 965477に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco 965477デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。