INSTRUCTIONS-PARTS LIST e 307-308 Rev. "6" 9-78 This manual contains IMPORTANT WARNINGS and INSTRUCTIONS READ AND RETAIN FOR REFERENCE ORACO SUPERSEDES 1-78 HYDRA-CLEAN" 1007 MODEL 226-813 SERIES "A" Includes Hose and Gun Kit and Chemical Injector Kit for injecting cleaning chemicals downstream from pump.
WA RNlNG HIGH PRESSURE SPRAY CAN CAUSE SERIOUS INJURY READ THESE WARNINGS BEFORE USING KEEP AWAY FROM SPRAY Because of the high pressure and velocity of the spray, fluids could penetrate the skin, causing serious injury. Operate equipment only after all instructions are clearly understood.
SETTING UP UNIT -A NOTE: Reference numbers and letters in paren- and the Parts Drawing. theses in the text refer to Figures 1, 3, 4 Refer to the engine instruction booklet provided with the unit. Prepare The Cleaning Solution Prepare and use cleaning solution according to manufacturer's instructions.
~ OPERATION Startup Before starting, be sure to read the safety warnings and setup instructions. Check oil and gasoline levels daily and grease the pump if necessary. Turn on the water supply. Trigger the gun to release any back pressure. WARNING or triggered position.
Lubrication Change the engine oil after every 50 hours of operation. every EO hours of operation. Remove excess grease Grease the pump's front bearing and main bearing after from the front bearing cavity. Replace the pump front cover before starting the engine.
- Accompanied By Smooth Decreased Delivery Operation Excessive Leakage suction piping (suction valve Plugged or constricted not fully open); Collapsed suction hose.
Valve Replacement .. Mount the valve disc (61 on the spring (7). See Fig 3. Then mount the spring in the cage recess (8). Slip thls Make sure that the O-rings (2 & 3)have been inserted in assembly into the head cavities behind the valve seat (5) the proper places according to the diagram.
Unloader Remove the locknut (67). adjusting nut (68) and spring washers (71). Remove bolts (511 and separate the upper and lower casings (48 and 49). All other parts can then be freely removed. To replace the cup and back-up ring (46 and 47): a. Cut through the old cup and back-up ring and b.
MODEL 226-813 SERIES "A" WITH HOSE, GUN AND NOZZLE Includes items 1-102 8 307-308.
PARTS LIST REF PART DESCRIPTION an REF PART DESCRIPTION NO. NO. aN NO. NO., 1 2 3 4 6 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 , 27 28 29 30 31 32 33 35 34 36 37 38 39 40 41 42 43 44 45 46 47 49 48 50 51 52 53 54 *104-868 *X ff x* *I f.
~ ACCESSORIES (Must be purchased separately) SPRAY HOSES Additional hoses may be used up to a maximum overall length of 150 ft 146 m) overall length. Purchase part no, 207-152 swivel union to connect hoses. Part No. Length Thd Size 19.5 mml 113 mml 3/8 npt Imbel 3/8 npt Imbel 205-EO9 1/2 in.
デバイスGraco Inc. 226-813の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco Inc. 226-813をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco Inc. 226-813の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco Inc. 226-813の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco Inc. 226-813で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco Inc. 226-813を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco Inc. 226-813の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco Inc. 226-813に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco Inc. 226-813デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。