750000 AL TERNA TING PRESSURE / L OW AIR L OSS MA TTRESS SYSTEM USER MANUAL Impor tant: Do not operate the Mattress System without rst reading and understanding this manual! Save this manual for future use. Info: The most current version of this manual can be found online at www.
2 750000-INS-LAB-RevC11 CONTENTS INTRODUCTION..................................................................................... 3 INTENDEDUSEOFTHISDEVICE ........................................................ 3 CONTRAINDICA TION .
750000-INS-LAB-RevC11 3 INTR ODUCTION Use this manual for set-up and operation of the Lumex AltaDyne 750000 Alternating Pr essure / Low Air Loss Mattr ess System. Read all instructions before using the mattr ess system. Save this manual for future r eference.
4 750000-INS-LAB-RevC11 IMPORT ANT SAFETY PRECA UTIONS The safety statements pr esented in this chapter refer to the basic safety information that should be obser ved by those using the Alternating Pr essure / Low Air Loss Mattr ess System.
750000-INS-LAB-RevC11 5 WARNING To reducetheriskofburns,electrocution,r e,or personalinjury: W ARNING:Donotleavethisproductunattended whenpluggedin.
6 750000-INS-LAB-RevC11 W ARNING:Patiententrapmentwithbedsiderails maycauseinjuryordeath.Thebedframeandits components,includingthemat.
750000-INS-LAB-RevC11 7 EQUIPMENT SYMBOLS Attention! Consult accompanying documents (this manual) “BF”symbol: Indicates that this product is in accordance with the degree of protection against .
8 750000-INS-LAB-RevC11 PR ODUCT DESCRIPTION PUMP AND MA TTRESS SY STEM pumpandmattresssystem CPRvalves mattress-pump connectors mattress footend symbol pump Pump: front quick connec.
750000-INS-LAB-RevC11 9 Pump: rear Pump: top panel pressur eadjustmentknob normalpressur eindicator lowpressur eindicator mainpowerswitch staticfunctionswitch Pr essur e adjust knob : The pressur e adjust knob controls the air pr essure output.
10 750000-INS-LAB-RevC11 Static function switch : Pr ess the static function switch to suspend alternating function, if needed; the pr essure inside the air tubes will then be adjusted to identical pr essure. Pr ess the static function switch again to change back to alternating mode.
750000-INS-LAB-RevC11 11 INST ALLA TION UNP ACKING 1. Befor e unpacking, check for obvious damage to the carton or its contents. If damage is evident, please notify the carrier and your Graham-Field equipment pr ovider . 2. Remove all loose packing fr om the car ton.
12 750000-INS-LAB-RevC11 PUMP AND MA TTRESS INST ALLA TION 1. Place the mattr ess on top of the bed frame; ensur e that the foot end symbol faces up at foot end as shown at right. 2. Fold open the wir e hangers on the back of the pump as shown at right.
750000-INS-LAB-RevC11 13 W ARNING:Locateallcordssothattheywillnotbe steppedon,trippedover ,orotherwisesubjectedto damageorstress. W ARNING:Donotuseahouseholdextensioncordif theelectricalcorddoesnotreachthepoweroutlet.
14 750000-INS-LAB-RevC11 OPERA TION 1. T urn the power switch to the ON position. 2. Adjust the pr essure adjust knob to the maximum position. Info: Set the pressure adjust knob to the maximum position for the quickest inflation at set-up; the mattress can then be adjusted to the desired pressure.
750000-INS-LAB-RevC11 15 under the patient's buttock ar ea; your ngers should just t. If the t is too loose, decr ease the setting. If your ngers do not t well, incr ease the setting two notches rmer . W ait ten minutes and then check again.
16 750000-INS-LAB-RevC11 MAINTENANCE CLEANING Perform the following cleaning pr ocedures befor e use. Pump : W ipe the pump with a clean, damp cloth and mild deter gent, and keep it away fr om dust. Air dr y . s NOTICE:Donotusephenolicproductsorcorrosive orpowderedcleanserstocleanthepump.
750000-INS-LAB-RevC11 17 Fuse replacement tool needed: small screwdriver 1. If you suspect a blown fuse, disconnect the plug fr om the wall outlet immediately . 2. Use a small scr ewdriver to r emove the cover of the fuse holder (fuse locations ar e shown in pictur e at right).
18 750000-INS-LAB-RevC11 SPECIFICA TIONS Pump Specication Power Supply 120V System: AC 120V 60 Hz Info: see rating label on product Fuse Rating T1A, 250V Cycle time 8 minutes Air input >4 LPM Dimensions (L x W x H) 9.8" x 5.3" x 3.7" (25 x 13.
750000-INS-LAB-RevC11 19 WARRANTY GF Health Pr oducts, Inc. warrants the Lumex AltaDyne 750000 Alternating Pr essure / Low Air Loss Mattr ess System for a period of twelve months for defects in workmanship and materials. If a pr oduct is deemed to be under warranty , GF Health Products, Inc.
USA Corporate Headquar ters: GF Health Products, Inc. 2935 Nor theast Parkway Atlanta, Georgia 30360 telephone: 770-368-4700 fax: 770-368-2386 www .grahamfield.
デバイスGraham Field 750000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graham Field 750000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraham Field 750000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graham Field 750000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graham Field 750000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graham Field 750000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraham Field 750000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graham Field 750000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraham Field 750000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。