753003-INS-LAB P/N 12709-000 5/05 ™ AltaDyne AutoFloat Alternating Pr essur e Management Plus Model # 753003 Model # 753004 OPERA TORS MANUAL Graham-Field Health Pr oducts 2935 Northeast Parkway Atlanta, Georgia 30360 1-800-347-5678 Fax: 1-800-726-0601 www .
2 Lumex ® AltaDyne AutoFloat W ar ranty T able Of Contents 1.0 W arranty ························································································································· 2 2.
3 Lumex ® AltaDyne AutoFloat Indications for Use/Safety Precautions 5.0 Safety Pr ecautions Review the following SAFETY PRECAUTIONS prior to using the AltaDyne Auto Float ™ System. A ttention, consult accompanying document Danger ous voltage 2.0 Symbols 3.
4 Lumex ® AltaDyne AutoFloat Description/Features 6.0 Description The AltaDyne AutoFloat is a portable air flotation system with on-demand alternating low pressur e treatment, designed to provide benefit to patients suffering fr om, or at risk of, developing pressur e ulcers.
5 Lumex ® AltaDyne AutoFloat Operator Control Panel 1. ON/ST ANDBY switches Contr ol Unit between On and ST ANDBY modes. 2. POWER INDICA TOR LED indicates AC power is present to the Contr ol Unit. 3. MODE SELECT Pr ess repeatedly to toggle thr ough operating modes, Auto/Float, Auto/A/P , Manual/Float and Manual/A/P .
6 Lumex ® AltaDyne AutoFloat Setting Up the System/Instructions for Use Theor y While in Automatic Float mode, the Contr ol Unit continually r epeats a deflation/inflation cycle. The inflation level of the mattress is lower ed until the lowest allowable flotation height is sensed (via feedback from the active sensors in the mattress).
7 Lumex ® AltaDyne AutoFloat Instructions for Use/Transfer ring Patients W ARNING Check patient at least ever y 8 hours or once per shift, to assure pr oper system inflation.
8 Lumex ® AltaDyne AutoFloat CPR/Cleaning/Care/Storage 13.0 System Cleaning, Car e and Storage 13.1 Cleaning 1. T o clean, use soap, water and a clean cloth to wipe down the Control Unit, power cor d, hoses and mattress. Do not use abrasive cleaners on the mattress.
9 Lumex ® AltaDyne AutoFloat T roubleshooting/Specifications 14.0 Tr oubleshooting SYMPTOM: CORRECTIVE ACTION M attress does not inflate or is too soft. Make certain the air hoses are not kinked, cracked, or split. V erify the hose couplings are fully engaged to contr oller .
デバイスGraham Field 753003の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graham Field 753003をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraham Field 753003の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graham Field 753003の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graham Field 753003で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graham Field 753003を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraham Field 753003の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graham Field 753003に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraham Field 753003デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。