Graham FieldメーカーUS0208PLの使用説明書/サービス説明書
ページ先へ移動 of 28
US0208-INS-LAB-RevD1 1 MODEL US0208 / US0208PL SEMI-ELECTRIC BED MODEL US0458 / US0458PL FULL-ELECTRIC / LO W BED USER MANU AL READ THIS MANU AL BEFORE OPERA TING THE P A TRIO T ™ HOMECARE BED . SA VE THIS MANU AL FOR FUTURE USE. INFO: THE MOST CURRENT VERSION OF THIS MANU AL CAN BE FOUND ONLINE A T www .
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 2 GF H ea lt h Pr od uct s, I nc . is n ot re sp on si bl e fo r typ og ra ph ic al e rr or s. Pa ck ag in g, w ar ran ti es , pr od uc ts an d sp ec i ca ti on s are s ub je ct t o ch ang e wi th ou t no ti ce.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 3 1 SAFETY The safety statements pr esented in this chapter refer to the basic safety information that the op- erator of the Patriot Homecar e Bed shall pay attention to and abide by .
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 4 2 INTRODUCTION, P A TRIO T HOMECARE BED USER MANU AL This manual contains assembly and maintenance instructions for your Model US0208 / US0208PL Semi-Electric and US0458 / US0458PL Full-Electric / Low Patriot bed.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 5 3 ASSEMBL Y INSTRUCTIONS HEAD AND FOO T ASSEMBL Y foot section head section motor cam hook rivet hook rivet Assembly , head and foot sections Note: Grid deck not shown for clarity 1.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 6 MO T OR ASSEMBL Y W ARNING: Assemble motor on bed as follows. While it is possible to install the motor backwards, avoid it! Incorrect installation could cause the bed to move in unexpected ways. Note that the motor ends are labeled and embossed with head and foot symbols (shown at right).
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 7 Install motor slide caps 7. Position the caps as shown at right so that the gr ooves in the slide cap are aligned with the gr ooves in the motor . 8. Apply straight downwar d pressur e to each end of the cap while sliding into the closed position.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 8 FULL-ELECTRIC BED ONL Y (US0458 / US0458PL): CASTER POSITION Any full-electric Patriot bed can be used as either a standar d-height or low-height bed by moving the casters.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 9 BED END ASSEMBL Y All bed models: Assemble bed head end 1. Insert one locking and one non-locking caster into bed end. Locking casters must be installed diagonally fr om each other . See pr evious page for full-electric caster position options.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 10 All models: Install bed end locking hardwar e 1. After bed head end has been attached, install Bed End Locking Har dwar e to act as a latch for each corner .
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 11 d f e 5. Fr om the inside, reattach the hairpin clip to the cor d’ s looped end as shown in d . This pr events the cor d from slipping back thr ough the frame bracket hole.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 12 Full-electric bed only (US0458 / US0458PL): Assemble hi/lo motor shaft to foot end gear bo x notches in hi/lo motor shaft coupler slide over gear box.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 13 HI/LO R OD ASSEMBL Y / BED LENGTH The hi/lo r od assembly consists of an inner and outer tube with a spring button lock to keep them together .
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 14 All models: Attach hi/lo rod to gearbo x or motor shaft pins Both ends of the hi/lo r od assembly have a slot to mount on the foot end motor shaft pins and bed end gearbox shaft pins. Follow steps 2-3 to mount the hi/lo r od assembly on the gearboxes.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 15 4 BED OPERA TION W ARNING: Ensure that bed is secure and assembled as instructed on previous pages before operating. Plug the power cor d into any grounded outlet. W ARNING: Do not leave the bed unattended when plugged in.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 16 CRANK OPERA TION: SEMI-ELECTRIC BED ONL Y (US0208 / US0208PL) Use the crank at the center foot of the semi- electric bed (shown at right) to change bed height (raise or lower entir e deck). TRENDELENB URG POSITION, ALL MODELS (HEAD END A T L OWER ELEV A TION THAN FOO T END) 1.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 17 5 SPECIFICA TIONS, ALL MODELS * * Specifications are subject to change without notice. Deck height High position Deck height: High Position US0208 / US0208PL: 24.0 inches US0458 / US0458PL with cast- ers in low position: 20.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 18 6 A CCESSORIES: BED RAILS Patriot Homecar e Bed decks are equipped with patent-pending slots specically for bed rail instal- lation, pr oviding a xed place to mount GF bed rails.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 19 GF6580B-1: Quar ter Rail GF6580B-1 Quarter Rail head end slot slotted head deck angle foot end head end slots head end pivot point pivot point slot f.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 20 L UMEX UNIVERSAL BED RAILS If you install Lumex universal bed rails, follow the installation instructions that accompany them; the following instructions ar e provided to describe the differ ences between the installation of bed rail cr ossbraces on Patriot grid beds and spring beds.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 21 GF6580A-1: Low Univ ersal Half Rail GF6580A-1 Low Universal Half Rail Cable tie Spr ing Bu tt on s with cable ti e Secu re cr ossb race to head de ck angle FOOTBOAR D Spr ing Bu tt on s G3 A G2 HEADBOARD B Fo llow same procedure for mounting half rails on foot-end using G3 slots .
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 22 7 SERVICE P AR TS, ALL MODELS Ser vice par ts for all bed models ar e shown below and on the following two pages. See pictures and tables for appr opriate ser vice par ts. Info: T o order ser vice par ts, contact our Customer Service depar tment at 800-365-2338 (fax 920-929-8213).
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 23 BED END COMPONENTS 3 5 6 7 4 1 2 8 HEAD FOOT Item Part number Description Semi-electric Full-electric US0208 US0208PL US0458 US0458PL 1 690-7001-901 .
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 24 BED SERVICE P ARTS 1 HEAD FOOT 2 3 4 Item Part number Description Semi-electric, H7920SE Full-electric, H7920FE US0208 / US0208PL US0458 / US0458PL 1.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 25 8 MAINTENANCE AND SAFETY CHECKS Perform the following as needed or between patient placements, whichever happens sooner: Electronics and Motor s Check all controls to ensure that all functions work properly .
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 26 9 WARRANTY GF Health Pr oducts, Inc. warrants the Patriot US0208 / US0208PL Semi-Electric Homecar e Bed Patriot US0458 / US0458PL Full-Electric / Low Bed as follows: T wo-year limited warranty for defects in workmanship and materials of mechanical components, frame, and electr onics.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 27 10 INDEX A Assembly instructions 5 B Bed end assembly 9 Bed end locking hardwar e, install 10 Bed extension kit, 84” 17 Bed height, low , full-elec.
U .S .A. Corporate Headquarters: GF Health Pr oducts, Inc. (“Graham-Field”) 2935 Northeast Parkway Atlanta, Geor gia 30360 telephone: 770-368-4700 www .
デバイスGraham Field US0208PLの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graham Field US0208PLをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraham Field US0208PLの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graham Field US0208PLの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graham Field US0208PLで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graham Field US0208PLを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraham Field US0208PLの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graham Field US0208PLに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraham Field US0208PLデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。