GrizzlyメーカーG6049の使用説明書/サービス説明書
ページ先へ移動 of 17
COPYRIGHT © MAY, 2002 BY GRIZZLY INDUSTRIAL, INC. 1821 VALENCIA ST., BELLINGHAM, WA 98227 WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.
For Your Own Safety Read Instruction Manual Before Operating This Equipment Indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
G6049 14/15 Gauge Angle Finish Nailer Kit -2 - 10. USE PROPER AIR HOSE for the tool. Make sure your air hose is in good condition and is long enough to reach your work without stretching. 11. WEAR PROPER APPAREL. Do not wear loose clothing, gloves, neck- ties, rings, bracelets, or other jewel- ry which may get caught in moving parts.
G6049 14/15 Gauge Angle Finish Nailer Kit -3 - Operating this nailer can propel objects into the air, causing immedi- ate eye damage. To protect yourself, always wear American National Standards Institute (ANSI) approved safety glasses or goggles when oper- ating this equipment.
G6049 14/15 Gauge Angle Finish Nailer Kit -4 - INTRODUCTION Commentary Most important, we stand behind our tools. If you have any service questions or parts requests, please call or write us at the location listed below.
G6049 14/15 Gauge Angle Finish Nailer Kit -5 - Compressed Air System Safety Yoke Mechanism The safety yoke is a mechanical device that can fail. Never rely on the safety yoke mechanism as an excuse to point the nailer at yourself or any bystanders. Serious injury may occur.
G6049 14/15 Gauge Angle Finish Nailer Kit -6 - OPERATION Loading Nailer To load your nailer: 1. Disconnect the air supply from the nailer! 2. Load nails at the top of the magazine in the T-slot as shown in Figure 1 . 3. Slide the stick of nails all the way down to the nose of the nailer.
G6049 14/15 Gauge Angle Finish Nailer Kit -7 - Operating Nailer Adjusting Depth Besides damaging your workpiece, deflection can cause injury if your free hand is securing the workpiece in the location that the nail deflects. 4. Press the trigger. If the nail drove into the wood far enough, continue with your intended operations.
G6049 14/15 Gauge Angle Finish Nailer Kit -8 - Always disconnect air from nailer whenever clearing a jammed nail! Clearing Jammed Nails The most frequent situation with any type of nailer is a nail jam. A jammed nail must be cleared before using the nailer again.
G6049 14/15 Gauge Angle Finish Nailer Kit -9 - Cleaning Nailer Use a good solvent to clean the nose assembly of the nailer. Always be sure that the nailer is dry before using it again.
G6049 14/15 Gauge Angle Finish Nailer Kit -10 - Replacing Pistons/O-Rings If you use your nailer day in and day out, Grizzly offers repair pistons as cheap insurance against wasted down time and lost profits in the event that a piston or pis- ton shaft becomes worn out.
G6049 14/15 Gauge Angle Finish Nailer Kit -11 - G6049 PART BREAKDOWN 93 7 33 12 14 13 11 10 9 7A 8 24 23 22 35A 20 49 5 50 30A 29 51 52A 6 5A 3 2 92 19 18 27 25 26 60 63 77 76A 66A 1 65 53 55 67A 54 7.
G6049 14/15 Gauge Angle Finish Nailer Kit -12 - 01 P6049001 LOCK NUT 02 P6049002 EXHAUST COVER 03 P6049003 SPRING PLATE 05A P6048005A CAP SCREW SW 06 P6049006 CAP 07A P6048007A BUT TON HD CAP SC R 08 .
TROUBLESHOOTING Air leaking at trigger valve area. Air leaking between hous- ing and hose. Air leaking between hous- ing and cap assembly. Tool skips nails while dis- charging. Tool runs slowly or has a loss of power. Fasteners frequently jam the nailer.
G6049 14/15 Gauge Angle Finish Nailer Kit -14 - Grizzly Industrial, Inc. warrants every product it sells for a period of 1 year to the original purchaser from the date of purchase. This warranty does not apply to defects due directly or indirectly to misuse, abuse, negligence, accidents, repairs or alterations or lack of main- tenance.
Name __________________________________________________________ Street __________________________________________________________ City ____________________ State ________ Zip _________ Phone Number __.
FOLD ALONG DOTTED LINE GRIZZLY INDUSTRIAL, INC. P.O. BOX 2069 BELLINGHAM, WA 98227-2069 TAPE ALONG EDGES--PLEASE DO NOT NAIL Name________________________________ Street________________________________.
デバイスGrizzly G6049の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Grizzly G6049をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGrizzly G6049の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Grizzly G6049の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Grizzly G6049で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Grizzly G6049を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGrizzly G6049の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Grizzly G6049に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGrizzly G6049デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。