AD-20 Installation Manual For replacement parts, contact the reseller from which the dryer was purchased or American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 U.S.A. T elephone: (508) 678-9000 / Fax: (508) 678-9447 e-mail: techsupport@amdry .
Retain This Manual In A Safe Place For Futur e Refer ence American Dryer Corporation products embody advanced concepts in engineering, design, and safety . If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation.
IMPOR T ANT YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPL Y AND THE GAS SUPPL Y OR THE STEAM SUPPL Y BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING , ADJUSTING , INST ALLA TION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) ST ANDARDS.
W ARNING The dryer must never be operated with the back guard removed. PERSONAL INJUR Y OR FIRE COULD RESUL T . IMPOR T ANT PLEASE OBSER VE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer .
Table of Contents SECTION I IMPOR T ANT INFORMA TION ............................................................................... 3 A. Receiving and Handling ..........................................................................................
SECTION VI ROUTINE MAINTENANCE .................................................................................. 3 0 A. Cleaning .........................................................................................................................
3 SECTION I IMPOR T ANT INFORMA TION A. RECEIVING AND HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery , the dryer and packaging, and wooden skid should be visually inspected for shipping damage.
4 B. SAFETY PRECAUTIONS W ARNING : For your safety , the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury , or loss of life. W ARNING : The dryer must never be operated with the back guard removed.
5 W ARNING : DO NOT dry mop heads. Contamination by wax or flammable solvents will create a fire hazard. W ARNING : DO NOT use heat for drying articles that contain plastic, foam, sponge rubber , or similarly textured rubber materials. Drying in a heated basket (tumbler) may damage plastics or rubber and may be a fire hazard.
6 SECTION II SPECIFICA TIONS A. SPECIFICA TIONS * Contact factory for information not listed, 3-phase (3ø) figures shown are for 4-wire service, non-reversing. NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.
7 NOTE : ADC reserves the right to make changes in specifications at any time without notice or obligation. Specifications AD-20.
8 SECTION III INST ALLA TION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.
9 B. LOCA TION REQUIREMENTS Before installing the dryer , be sure the location conforms to local codes and ordinances. In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1 LA TEST EDITION, or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.
10 C. DR YER ENCLOSURE REQUIREMENTS Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of 6-inches (15.24 cm) above the dryer ’ s outer top; except along the front of the dryer which may be closed if desired.
11 D. FRESH AIR SUPPL Y REQUIREMENTS The AD-20 air supply (make-up air) must be given careful consideration to assure proper performance of each dryer . An unrestricted source of air is necessary for each dryer . As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of a minimum of 1/4 square feet (0.
12 E. EXHAUST REQUIREMENTS DO NOT use a nonmetal flexible vent or a metal vent that is smaller than 4” (10.2 cm) in diameter or exhaust hoods with magnetic latches. DO NOT exhaust dryer into a chimney , furnace, cold air vent, attic, crawl space, or any other vent used for venting.
13 IMPOR T ANT VENTING REMINDERS 1. Ductwork size and installation should be done by a qualified professional. 2. The dryer must be exhausted to the outdoors. 3. Ductwork should be routed as short as possible to the outdoors with as few elbows as possible.
14 F . ELECTRICAL INFORMA TION 1. Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes.
15 2) Electric Models ONL Y ALL electrically heated dryers must be connected to the electric service shown on the dryer ’ s data label, which is affixed to the upper left area of the inner back panel. The connecting wires must be properly sized to handle the rated current.
16 If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord or pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the dryer .
17 b. Electric Models Only 1) Single-Phase (1ø) W iring Connections/Hookup If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord or pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel.
18 If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord or pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the dryer .
19 IMPOR T ANT : Figures shown are for non-reversing models ONL Y . IMPOR T ANT : The wire size must be properly sized to handle the related current. NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.
20 G . GAS INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms to local and state regulations or codes.
21 2. T echnical Gas Data a . Gas Specifications * Measured at outlet side of gas valve pressure tap when gas valve is on. b. Gas Connections Inlet connection ------------- 3/8” N.
22 3. Piping Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LA TEST EDITION, or in Canada, CAN/CGA-B149.
23 Consistent gas pressure is essential at ALL gas connections. It is recommended that a 1/2-inch (12.7 mm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.
24 H. PREP ARA TION FOR OPERA TION/ST AR T -UP The following items should be checked before attempting to operate the dryer: 1. Read ALL “ CAUTION ,” “ W ARNING ,” and “ DIRECTION ” labels attached to the dryer .
25 I. PREOPERA TIONAL TESTS ALL dryers are thoroughly tested and inspected before leaving the factory . However , a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.
26 J. SHUT DOWN INSTRUCTIONS If the dryer is to be shut down (taken out of service) for a period of time, the following must be performed: 1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker . 2. Discontinue the heat supply: a.
27 SECTION IV SER VICE/P AR TS INFORMA TION A. SER VICE 1. Service must be performed by a qualified trained technician, service agency , or gas supplier .
28 SECTION V WARRANTY INFORMA TION A. RETURNING W ARRANTY CARDS 1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main door glass.
29 2. Each part must be tagged with the following information: a. Model number and serial number of the dryer from which part was removed. b. Nature of failure (be specific). c . Date of dryer installation. d. Date of part failure. e . Specify whether the part(s) being returned is for a replacement, a credit, or a refund.
30 SECTION VI ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer , as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location.
31 90 DA Y S Inspect and remove lint accumulation in customer furnished exhaust ductwork system from dryer ’ s internal exhaust ducting. W ARNING : THE ACCUMULA TION OF LINT IN THE EXHAUST DUCTWORK CAN CREA TE A POTENTIAL FIRE HAZARD. W ARNING : DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILA TION AIR.
32 SECTION VII DA T A LABEL INFORMA TION A. DA T A LABEL Contact American Dryer Corporation When contacting American Dryer Corporation certain information is required to insure proper service/parts information from ADC . This information is on the data label located on the left side panel area behind the control (access) door .
33 THE DA T A LABEL 1. MODEL NUMBER The model number is an ADC number , which describes the size of the dryer and the type of heat (gas, electric, or steam). 2. SERIAL NUMBER The serial number allows ADC to gather information on your particular dryer .
ADC 113379 1 - 10/16/02-25 2 - 10/17/02-250 3 * 12/03/02-250.
デバイスAmerican Dryer Corp. AD-20の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
American Dryer Corp. AD-20をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmerican Dryer Corp. AD-20の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。American Dryer Corp. AD-20の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。American Dryer Corp. AD-20で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
American Dryer Corp. AD-20を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmerican Dryer Corp. AD-20の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、American Dryer Corp. AD-20に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmerican Dryer Corp. AD-20デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。