American Dr yer Corpor ation 88 Currant Road Fall River MA 02720-4781 T elephone: (508) 678-9000 / Fax: (508) 678-9447 e-mail: techsupport@amdry .com www .
ML-55 Phase 7 We have tried to make this manual as complete as possible and hope you will find it useful. ADC reserves the right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and material, and to change or discontinue models.
T ab le o f Contents __________ Safety Precautions ....................................... 2 Specifications/Component Identification ..... 3 S pecifications ...................................................................... 3 Component Identification .
2 American Dryer Corp. 113345-9 S AFETY P RECA UTIONS __________ Warning For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life. The dryer must never be operated with any of the back guards, outer tops, or service panels removed.
113345-9 www.amdry.com 3 MAXIMUM CAPACITY (DRY WEIGHT) 55 lb 25 kg TUMBLER DIAMETER 37” 94 cm TUMBLER DEPTH 30” 76.2 cm TUMBLER VOLUME 18.67 cu ft 0.528 cu m TUMBLER/DRIVE MOTOR 3/4 hp 0.56 kW DOOR OPENING (DIAMETER) 31-3/8” 79.7 cm WATER CONNECTION 3/4-11.
4 American Dryer Corp. 113345-9 Component Identification _____________ Dryer Front View Illus. No. Description 1 Controls 2 Control (top access) Door Assembly 3 Main Door Assembly 4 Lint Compartment Area (lint screen located behind door) 5 Data Label and Installation Label Dryer Rear View Illus.
113345-9 www.amdry.com 5 ! ! ! ! Unpacking/Setting Up _________________ Remove protective shipping material (i.e., plastic wrap, and/ or optional shipping box) from dryer. Important Dryer must be transported and handled in an upright position at all times.
6 American Dryer Corp. 113345-9 ! ! ! ! ! Note Component failure due to dry cleaning solvent fumes will void the warranty. Exhaust Requirements _________________ General Exhaust Ductwork Information Exhaust ductwork should be designed and installed by a qualified professional.
113345-9 www.amdry.com 7 ! ! ! ! Important Do not use screens, louvers, or caps on the outside opening of the exhaust ductwork. Single Dryer Venting When possible, it is suggested to provide a separate exhaust duct for each dryer.
8 American Dryer Corp. 113345-9 ! ! ! ! ! ! Important For extended ductwork runs, the cross section area of the ductwork can only be increased to an extent. When the ductwork approaches the maximum limits noted in this manual, a professional heating, ventilating, and air-conditioning (HVAC) firm should be consulted for proper venting information.
113345-9 www.amdry.com 9 For added personal safety, when possible, it is suggested that a separate ground wire (no. 18 minimum) be connected from the ground connection of the dryer to a grounded cold water pipe. Do not ground to a gas pipe or hot water pipe.
10 American Dryer Corp. 113345-9 Single-Phase Electrical Lead Connections Black + Positive White or Red + Neutral or L2 Green + Ground ! For 110V Applications For 208-230/240V Applications A ground lug is provided in the rear electrical box to connect your service ground.
113345-9 www.amdry.com 11 ! Type of Gas Manifold Pressure* In-Line Pressure Natural 3.5 inches W.C. 6.0-12.0 inches W.C. 8.7 mb 14.92 - 29.9 mb Liquid Propane 10.
12 American Dryer Corp. 113345-9 TYPE OF GAS Btu/hr Rating kcal/hr Rating Natural Liquid Propane Qty. D.M.S.* Part No. Qty. D.M.S.* Part No. 160,000 40,320 3 #29 140820 3 #48 140804 Liquid Propane Conversion Kit Part Number 881598 Shaded area is stated in metric equivalent * Drill Measurement Size (D.
113345-9 www.amdry.com 13 Operating Steam Pressure Maximum 125 psig* 861.84 kPa Heat Input (Normal Load) 4.2 Bhp Consumption (Approximate) 144.7 lbs/hr 65.7 kg/hr Shaded areas are stated in metric equivalents *The minimum operating pressure is 100 psig (689.
14 American Dryer Corp. 113345-9 Steam Damper Air Piston (Flow Control) Operation Adjustment Although the steam damper operation was tested and adjusted prior to shipping at 80 psi (5.52 bar), steam damper operation must be checked before the dryer is put into operation.
113345-9 www.amdry.com 15 ! ! ! ! Preparation For Operation/Start-Up ___ The following items should be checked before attempting to operate the dryer: • Read all “ CAUTION,” “WARNING ,” and “ DIRECTION ” labels attached to the dryer. • Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label.
16 American Dryer Corp. 113345-9 ! ! ! ! Check the electric service phase sequence (3-phase [3ø] models only). While the dryer is operating, check to see if the blower wheel (impellor/fan) is rotating in the proper direction. Looking from the front, the blower wheel (impellor/fan) should spin in the clockwise (CW) direction.
113345-9 www.amdry.com 17 W ARRANTY I NFORMA TION _______ Returning Warranty Card _____________ Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main door glass.
18 American Dryer Corp. 113345-9 R OUTINE M AINTENANCE ________ Cleaning ______________________________ A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer, as well as throughout the ductwork system.
113345-9 www.amdry.com 19 P ROCEDURE FOR F UNCTIONAL C HECK OF R EPLACEMENT C OMPONENTS _________________ Microprocessor Controller (Computer) Board _________________________________ Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer.
20 American Dryer Corp. 113345-9 M ANU AL R ESET B URNER H I -L IMIT I NSTRUCTIONS ________________ Phase 7 ________________________________ This dryer was manufactured with a manual reset burner Hi-Limit thermostat, which is monitored by the Phase 7 computer.
113345-9 www.amdry.com 21 Installation _____________________________ Requirements The F.S.S. must be supplied with a minimum water pipe size of 1/2” and be provided with 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) of pressure. For use of optional manual bypass, a second source with the same piping and pressure requirements is required.
22 American Dryer Corp. 113345-9 Typical Water Supply Optional Manual Bypass Provisions are made in the dryer’s F.S.S. for the installation of an optional manual bypass.
113345-9 www.amdry.com 23 System Reset _________________________ After the microprocessor determines that the situation is under control and shuts the water being injected into the basket (tumbler) off, the microprocessor display will read “ F .S.S.
ADC 113345 9 - 12/01/04-6.
デバイスAmerican Dryer Corp. ML-55IIの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
American Dryer Corp. ML-55IIをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmerican Dryer Corp. ML-55IIの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。American Dryer Corp. ML-55IIの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。American Dryer Corp. ML-55IIで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
American Dryer Corp. ML-55IIを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmerican Dryer Corp. ML-55IIの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、American Dryer Corp. ML-55IIに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmerican Dryer Corp. ML-55IIデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。