ML G33 Installa tion/Oper a tor Manual W ARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion and to prevent property damage, personal injury or death. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
“IMPORT ANT NOT E TO PUR CHASER” Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas.
IMPORT ANT Y ou must disconnect and lockout the electric supply and the gas supply before any covers or guards are removed from the machine to allow access for cleaning, adjusting, installation, or testing of any equipment per OSHA standards.
4 Maytag Co. 1 13413 - 1 1 Safety Precautions ____________________ Warning For your safety , the information in this manual must be followed to minimize the risk of fire or explosion and to prevent property damage, personal injury , or loss of life. The dryer must never be operated with any of the back guards, outer tops, or service panels removed.
1 13413 - 1 1 Maytag Co. 5 ! Warning T o reduce the risk of personal injury , inst all lockable doors to prevent public access to the rear of the dryers.
6 Maytag Co. 1 13413 - 1 1 MA XI MU M C A P A C I T Y ( DRY WEI GH T ) PER PO CKE T 30 l b 13. 61 kg T U M BL ER DI AM ET ER 3 0 ” 76. 20 cm T U M B L E R D E P T H 27” 68. 58 cm T UMBL E R V OLUME PER PO CKET 11 . 0 4 c u ft 312. 62 L TUM B L E R/D R I V E MO TOR PER PO CKET 1/4 h p 0.
1 13413 - 1 1 Maytag Co. 7 Specifications _______________________________________________________________________.
8 Maytag Co. 1 13413 - 1 1 ! Installation Procedures _______________ Installation should be performed by competent professional in accordance with local, state, and country codes. In the absence of these codes, the installation must conform to applicable American National S tandards: ANSI Z223.
1 13413 - 1 1 Maytag Co. 9 F r esh Air Supply R equir ements _______ When the dryer is operating, it draws in room air , heats it, passes this air through the tumbler , and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors.
10 Maytag Co. 1 13413 - 1 1 ! Outside Ductwork Protection T o protect the outside end of the horizontal ductwork from the weather , a 90° elbow bent downward should be inst alled where the exhaust exits the building.
1 13413 - 1 1 Maytag Co. 11 Impor tant No more than 4 dryers should be connected to 1 main common duct. The illustration below shows the minimum cross-sectional area for multiple dryer round or square venting. These figures must be increased if the main duct run from the last dryer to where it exhausts to the outdoors is longer than 12 feet (3.
12 Maytag Co. 1 13413 - 1 1 Gas Infor ma tion _______________________ It is your responsibility to have all plumbing connections, materials, and workmanship conform to local and state regulations or codes of the country of destination.
1 13413 - 1 1 Maytag Co. 13 ! ! ! ! ! Warning Fire or explosion could result due to failure of isolating or disconnecting the gas supply as noted. Note Undersized gas piping will result in ignition problems, slow drying, increased use of energy , and can create a safety hazard.
14 Maytag Co. 1 13413 - 1 1 G as Speci f i cati ons f or Non-CE A pproved Dr yers *** G as T ype and N o mina l H ea tin g Va l u e Suppl y Pressure ** Gro ss Heat I nput Or ific e S iz e ** Or ifice ( Inj ect or) Qua ntity Bur n er Pressur e Bt u/ f t 3 in WC B tu/h r kW DMS mm in WC N at u r al 1, 000 7.
1 13413 - 1 1 Maytag Co. 15 Piping/Connections The dryer is provided with two 1/2” N.P .T . (3/8” B.S.P .T . for CE dryers) inlet pipe connections (1 for each tumbler) at the rear of the dryer . If a sep arate feed is provided for each tumbler from the main supply line (header), then a 1/2” (12.
16 Maytag Co. 1 13413 - 1 1 ! ! Unre gulated Gas V alve Regulate (govern) gas externally (refer to “Supply Pressure” in chart on page 14) to the correct gas pressure for the gas being used. Operate dryer through 1 complete cycle to ensure proper operation.
1 13413 - 1 1 Maytag Co. 17 ! Reinstall the burner tube onto the burner base. If converting from unregulated gas, use a flat screwdriver , remove the cap with blocking pin and install the regulator vent cap from the kit. Install the gas train back into the dryer gas train enclosure.
18 Maytag Co. 1 13413 - 1 1 ! ! ! Preoper a tional Instr uctions __________ Impor tant For more detailed information regarding the microprocessor controller (computer), refer to the microprocessor user’s manual included with the dryer.
1 13413 - 1 1 Maytag Co. 19 ! ! ! ! Note When ordering replacement parts from the Maytag distributor or the Maytag Co. be sure to give them the correct model number and serial number so that your parts order can be processed in an expeditious manner.
20 Maytag Co. 1 13413 - 1 1 CE Label Data Label Infor ma tion _____________________________________________________________ Standard Label When contacting Maytag, the information on the data label is required to ensure proper service/parts assistance.
1 13413 - 1 1 Maytag Co. 21 NOTES _____________________________________________________________________________________ ________________________________________________________________________________.
Part No. 1 13413 1 1 - 01/15/09 - 10.
デバイスAmerican Dryer Corp. MLG33の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
American Dryer Corp. MLG33をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmerican Dryer Corp. MLG33の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。American Dryer Corp. MLG33の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。American Dryer Corp. MLG33で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
American Dryer Corp. MLG33を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmerican Dryer Corp. MLG33の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、American Dryer Corp. MLG33に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmerican Dryer Corp. MLG33デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。