AD1200EXP MCS Hard-wire Controller Expander Installation Instructions The manual describes the installation procedures for the American Dynamics AD1200EXP MCS Hard-wire Controller Expander. Before installation, become familiar with all of the special features and warnings associated with this equipment.
This software/firmware is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software is furnished to the purchaser under a license for use on a single system.
The installation of this product should be made by qualified service personnel and should conform to all local codes. QA301D ! W W W W A A A A R R R R N N N N II I I N N N N G G G G To reduce the risk of fire or shock hazard, do not expose this product to rain or moisture.
T able of Contents DESCRIPTION............................................................................................................................ 1 FEATURES .....................................................................................
1 AD1200EXP DESCRIPTION DESCRIPTION The AD1200EXP Hardwired Controller Expander increases the number of pan/tilt sites controlled from a single AD1200A Hard-wired Controller from one to four. Cascading multiple AD1200EXP units increases the number of pan/tilt sites available from four to a maximum of sixteen.
2 INSTALLATION Front Panel Description Site Selection Pushbuttons: Four spring-loaded pushbuttons select the individual pan/tilt unit the operator wishes to control (see Figure 2).
3 AD1200EXP INSTALLATION Figure 3 - AD1200EXP Rear Panel Layout 14- P in C onne c ter s ( 4) 1 2 3 4 U D R L 1 2 R C I F Z N C N C N C U D R L 1 2 R C I F Z N C N C N C 1 2 3 Gr ound C onne c ti on 4 .
4 Mounting The AD1200EXP is suitable for desktop operation or mounting in a standard EIA rack. The American Dynamic's AD2117/21 Rack Mount Hardware Kit is recommended for mounting one or two AD1200EXPs in a standard EIA rack. Power The AD1200EXP is configured for use with 24VAC power.
AD1200EXP INSTALLATION 5 A D1200EX P 1 2 3 4 U D R L 1 2 R C I F Z N C N C N C U D R L 1 2 R C I F Z N C N C N C 0 1 2 3 G 1 2 3 4 AUT O SC AN 120V 60Hz LEN S ADJ UST AUX P/ T A/ P LEN S U D R L 1 2 H.
Cascading Multiple AD1200EXP Units Multiple AD1200EXP units are used to increase the number of pan/tilt sites available to a single AD1200A Hard-wired Controller from four to a maximum of sixteen. Each AD1200EXP unit is provided with one 5-pin strap harness for cascading purposes.
7 AD1200EXP INSTALLATION 1 2 3 4 0 1 2 3 G A D1200EX P 1 2 3 4 0 1 2 3 G 0 1 2 3 G 1 2 3 4 C ha ssis G r ound C onne c ti on ( 1 8 AWG S o l i d Wi re) to AD1200A H a rd- w i r e Cont r oll e r C ha s.
8 Powering Multiple AD1200EXP Units Connecting multiple (maximum of 4) AD1200EXP units to one AD1200A Controller requires the use of an external 120VAC to 24VAC step-down transformer. NOTE: Connecting multiple AD1200EXPs for European operation requires the use of a 230VAC to 24VAC step-down transformer.
9 AD1200EXP INSTALLATION AUT O SC A N 120V 60Hz LEN S ADJ US T AUX P/T A/P LEN S U D R L 1 2 H R C I F Z CP 1 2 3 4 OF F A D1200A Ha r d- w ir e C ontr olle r A D1200EX P Un it #1 24VAC CO MMO N 24VAC.
10 Connecting Multiple AD1200EXP Units A maximum of four AD1200EXP units may be connected to one AD1200A Hard-wired Controller. All AD1200EXP units connect to the AD1200A Hard-wired Controller via a single 14-pin connector (provided with the AD1200 Hard-wire Controller).
11 Figure 8 - Multiple AD1200EXP Unit -to- AD1200A Hard-wired Controller Connection AD1200EXP INSTALLATION U D R L 1 2 R C I F Z N C N C N C U D R L 1 2 R C I F Z N C N C N C 0 1 2 3 G 1 2 3 4 U D R L.
12 AD1200EXP to Pan/Tilt Site Connection The AD1200EXP provides connection ports to four pan/tilt units via 14-pin connectors. NOTE: The AD1200EXP does not provide power to either the pan/tilt or the camera. 1. Using Table 4 as reference, connect each lead from the pan/tilt unit to the appropriate terminal of the 14-pin connector (see Figure 9).
13 AD1200EXP INSTALLATION 1 2 3 4 U D R L 1 2 R C I F Z N C N C N C 0 1 2 3 G 12 3 4 A D1200EX P U D R L 1 2 R C I F Z N C N C N C A D1240 P a n/ T ilt U D R L 1 2 R C I F Z N C N C N C 1 ZOOM FOCUS I.
14 CCTV Switcher System Connection AD1200EXP units provide a 5-pin connector for use with CCTV switcher systems. Each AD1200EXP unit is provided with one 5-pin strap harness and two 5-pin mating connectors.
15 AD1200EXP INSTALLATION 120V 60H z 120V 60H z J1 J2 J2 J1 AD 1416L w / Loopi ng Re a r P a ne l M ONIT OR A B CA MERA J3 M ONIT OR AB CA MERA 12 34 56 7 89 1 0 1 1 1 2 1 4 1 5 1 6 13 J3 AD 1416 w / .
16 SETUP 4-Position DIP Switch A 4-position DIP switch configures the AD1200EXP for the number of operational cameras and for use within a CCTV switching system. The 4-position DIP switch is mounted on the AD1200EXP rear panel (see Figure 12). Using Table 8 as reference, read the following descriptions of each of the four DIP switches.
17 AD1200EXP OPERATION OPERATION Single AD1200EXP Unit Operation A single AD1200EXP unit provides operational control to a maximum of four pan/tilt sites. 1. Press the appropriate pushbutton (1-4) to select the desired pan/tilt site (see Figure 13). 2.
.
APPENDIX.
.
A1 AD1200EXP INDEX Cable Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Auxiliary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Cascading Multiple AD1200EXP Units . . . . . . . . . . . . . . 6 Connector, 14-Pin .
A2 AD1200EXP DIMENSIONS 1. 74" 44. 5m m 10. 3" 261. 6m m 8. 5" 216m m 12 34 MCS PTZ CONTROLLER EXPANDER.
.
An American Dynamics Product Designed and built by Sensormatic CCTV Systems Division One Blue Hill Plaza Pearl River, New York, 10965 (914) 624-7600 Technical Support Center: 800-442-2225 FAX: (914) 6.
デバイスAmerican Dynamics AD1200EXPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
American Dynamics AD1200EXPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmerican Dynamics AD1200EXPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。American Dynamics AD1200EXPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。American Dynamics AD1200EXPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
American Dynamics AD1200EXPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmerican Dynamics AD1200EXPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、American Dynamics AD1200EXPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmerican Dynamics AD1200EXPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。