American DynamicsメーカーRASIPPS-1の使用説明書/サービス説明書
ページ先へ移動 of 18
1 SpeedDome Op tima Indoor Installation Guide RASI Series 2 Before performing these steps, ensure powe r is off and read addit ional i nformation at tached for important detai ls and warnings! U s i ng the te m p l a t e s up p lie d , c ut a h o l e in th e c e iling .
80 00- 269 2- 01 , R e v . E P age 2 of 1 8 5 S S 6 7 S ec u r e t h e h o u s i n g t o a s tr o ng s t r uc t ur a l c e ilin g m e m b e r . S e c ur e the ho us ing to th e c e iling .
1 SpeedDo me Optima Outd oor In stallatio n Guide RASO Series 2 = Step Prevent s Before perfor m ing t hese steps, ensure pow er is off a nd r ead additi onal inf ormation attached fo r importa nt det ails and warni ngs! W a ter In trus i o n.
4 5 B A t t ac h b u bb l e t o h ou s i n g. S e t the d o m e a d d r e s s a nd t er m i n at e t h e do me , i f ne c e s s a ry . L o os en t hr ee c a pt i v e s c r ew s an d pu s h i n al l t h r ee t abs s im ult a ne o us ly to re le a s e t h e as s em bl y f r om t h e h ou s i n g.
SPEEDDOME OPTIM A HOUSING 8000-2692-01, REV. E CONTINUATION OF INSTALLATION GUIDE 5 of 18 SpeedDome ® Optima Housing Continuation of Installation Information RASI Indoor Series RASO Outdoor Serie s Contents To the Installer ..........................
SPEEDDOME OPTIM A HOUSING 8000-2692-01, REV. E CONTINUATION OF INSTALLATION GUIDE 6 of 18 ! Warnings and Cautions Please review the following warning s and cautions before you begin installation or service. Warnings WARNING! Always use proper lift and safety equipment for the location and type of installation.
SPEEDDOME OPTIM A HOUSING 8000-2692-01, REV. E CONTINUATION OF INSTALLATION GUIDE 7 of 18 Preventing Condensation in Outdoor Domes Damage, missing parts, or procedures that most often allow water to enter the housing are as follows (refer to figures opposite): Mounts that allow water to enter the air path.
SPEEDDOME OPTIM A HOUSING 8000-2692-01, REV. E CONTINUATION OF INSTALLATION GUIDE 8 of 18 Cable Requirements Data Cable The table below shows requirements for SensorNet, RS-422, and Manchester net works. For more information about communi cation protocols and cable networks, see Communication Protocols and Cable Networks, 8000-2573 -19.
SPEEDDOME OPTIM A HOUSING 8000-2692-01, REV. E CONTINUATION OF INSTALLATION GUIDE 9 of 18 Wo rst-Case M eters Low Line V (Feet) 117 130 (425) 100 80 (250) 90 60 (200) 117 160 (525) 100 100 (325) 90 60.
SPEEDDOME OPTIM A HOUSING 8000-2692-01, REV. E CONTINUATION OF INSTALLATION GUIDE 10 of 18 Troubleshooting If a failure cannot be easily fixed external to the dome, send the dome to a repair center. No power (no LEDs light). Check for power comi ng in from J-box or controller.
SPEEDDOME OPTIM A HOUSING 8000-2692-01, REV. E CONTINUATION OF INSTALLATION GUIDE 11 of 18 Illustrated Parts List Not all of the parts, which are shown for clarity, are orderable. Parts are subjec t to change based on design improvements and availability.
SPEEDDOME OPTIM A HOUSING 8000-2692-01, REV. E CONTINUATION OF INSTALLATION GUIDE 12 of 18 Outdoor Housing Indoor/Outdoor Housi ng Assy. 0400-1208-01 3 Housing, Alumi num 0500-9175-01 4 Sun Shield 050.
SPEEDDOME OPTIM A HOUSING 8000-2692-01, REV. E CONTINUATION OF INSTALLATION GUIDE 13 of 18 Camera/Motor Assembly 18 20 19 22 21 17 14 15 16 Tilt Assy. 0400-1207-01/-02 Base Assy.
SPEEDDOME OPTIM A HOUSING 8000-2692-01, REV. E CONTINUATION OF INSTALLATION GUIDE 14 of 18 Base Assy. 0400-1203-01 14 Bearing, Pan 2510-0040-01 15 Pan Motor Assy.
SPEEDDOME OPTIM A HOUSING 8000-2692-01, REV. E CONTINUATION OF INSTALLATION GUIDE 15 of 18 Specifications Operation Manual pan speed ................ 1–50° per second Target pan spee d ................. 100° per se cond max. Pan trav el ..........
SPEEDDOME OPTIM A HOUSING 8000-2692-01, REV. E CONTINUATION OF INSTALLATION GUIDE 16 of 18 Electrical Power Line Input voltag e ........................... 24–30V ac, Class 2 LPS Design tolera nce ..................... 16–36Vac Line frequenc y ...
SPEEDDOME OPTIM A HOUSING 8000-2692-01, REV. E CONTINUATION OF INSTALLATION GUIDE 17 of 18 Manchester Communicati ons Cable topology ...................... Daisy chain Wire configuratio n ................. Single t wis ted pair 18AWG (Belden 8760), polar ized, shielded Connector .
SPEEDDOME OPTIM A HOUSING 8000-2692-01, REV. E CONTINUATION OF INSTALLATION GUIDE 18 of 18 Declarations Regulatory Compliance Emissions ............................. 47 CFR, Part 15 ICES-003 EN55022 Immunity ............................... EN 50130-4 (CE) Safety .
デバイスAmerican Dynamics RASIPPS-1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
American Dynamics RASIPPS-1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmerican Dynamics RASIPPS-1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。American Dynamics RASIPPS-1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。American Dynamics RASIPPS-1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
American Dynamics RASIPPS-1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmerican Dynamics RASIPPS-1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、American Dynamics RASIPPS-1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmerican Dynamics RASIPPS-1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。