FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-214c MODEL: H300 Freestanding W oodstove 04/13/06 Installer : Please complete the details on the back cover and leave this manual with the homeowner . Homeowner: Please keep these instructions for future reference.
Hampton H300 Cast Freestanding Woodstove 2 Thank-you for purchasing a HAMPTON FIREPLACE PRODUCT . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the HAMPT ON DEALER in your area.
Hampton H300 Cast Freestanding Woodstove 3 T ABLE OF CONTENTS SAFETY LABEL Safety Label for H300 .................................................... 4 INST ALLA TION Unit Dimensions ............................................................ 5 Pre-installation Assembly .
Hampton H300 Cast Freestanding Woodstove 4 This is a copy of the label that accompanies each Hampton H300 Freestanding Woodstove. We have printed a copy of the contents here for your review . SAFETY LABEL HOT WHILE IN OPERA TION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE A W A Y .
Hampton H300 Cast Freestanding Woodstove 5 INST ALLA TION To p Vi e w Front V iew Side V iew UNIT DIMENSIONS.
Hampton H300 Cast Freestanding Woodstove 6 INST ALLA TION PRE-INST ALLA TION ASSEMBL Y After removing the stove from its packing, open the front door and remove the contents from the fi rebox, leaving the bricks in place. Rotating Elbow This stove can be connected to either a top or rear vent exit by simply reversing the orientation of the elbow .
Hampton H300 Cast Freestanding Woodstove 7 INST ALLA TION RESIDENTIAL INST ALLA TION 1) Please read this entire manual before you install and use your new woodstove. Failure to follow instructions may result in property damage, bodily injury or even death.
Hampton H300 Cast Freestanding Woodstove 8 INST ALLA TION Residential Installation “C” V ent (Single W all) Unit (with Heat Shield) From Unit From From Flue Center-Line Corner A B C D E F H300 17&.
Hampton H300 Cast Freestanding Woodstove 9 MINIMUM ALCOVE CLEARANCE TO COMBUSTIBLE MA TERIALS This Hampton Freestanding model has been alcove approved and must be installed with a listed double wall connector to the ceiling level.
Hampton H300 Cast Freestanding Woodstove 10 FLOOR PROTECTION A combustible fl oor must be protected by non-combustible material (like tile, concrete board, or certifi ed to UL-1618 or as defi ned b.
Hampton H300 Cast Freestanding Woodstove 11 Horizontal Installation Standard Ceiling Installation INST ALLA TION Note: Increasing the chimney height above this minimum level will sometimes help your unit to “breathe” better by allowing a greater draft to be cre- ated.
Hampton H300 Cast Freestanding Woodstove 12 MASONR Y FIREPLACE There are listed kits available to connect a stove to a masonry fi replace. The kit is an adapter that is installed at the location of the fi replace damper . The existing damper may have to be removed to allow installation.
Hampton H300 Cast Freestanding Woodstove 13 Method A : 12" (304.8 mm) Clearance to Combustible W all Member: Using a minimum thickness 3.5" (89 mm) brick and a 5/8" (15.9 mm) minimum wall thickness clay liner , construct a wall pass-through.
Hampton H300 Cast Freestanding Woodstove 14 INST ALLA TION RECOMMENDED HEIGHTS FOR WOODST OVE FLUE Simple rules on draft. See T able 1. 1) At sea level minimum height is 12' straight. 2) Add the following vertical height to compen- sate for: 45 deg.
Hampton H300 Cast Freestanding Woodstove 15 MOBILE HOME INST ALLA TION Once you have properly marked the position of your unit and the fl oor protection as outlined in the Residential Installation items #1 through #8, a supply of fresh air has to be supplied to your unit.
Hampton H300 Cast Freestanding Woodstove 16 AMERI-TECHS Qty .Part # Description 1 6DCC Connector 1 6HSRS-12 R o o f Support (6PLRS-12 - BK) 1 6F Flashing 1 6HS-36 Chimney Length 1 6HS-18 Chimney Length 1 6HS-RCS Rain Cap (6PL-MPC) SIMPSON DURA-PLUS Qty .
Hampton H300 Cast Freestanding Woodstove 17 DOOR REMOV AL INST ALLA TION BRICK INST ALLA TION Firebrick is included to extend the life of your stove and to radiate heat more evenly . Check to see that all fi rebricks are in their correct positions and have not become misaligned during shipping.
Hampton H300 Cast Freestanding Woodstove 18 CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
Hampton H300 Cast Freestanding Woodstove 19 SIDE SHELF INST ALLA TION INST ALLA TION 1) Secure two Support Gussets and attach Bracket to the underside of Shelf. Bracket Support Gussets 2) Remove Stove T op and place Side Shelf on to Stove Side as shown, aligning Bracket with notch in Stove Side as shown.
Hampton H300 Cast Freestanding Woodstove 20 OPERA TING INSTRUCTIONS 13) All fuel burning appliances consume oxygen during operation. It is important that you supply a source of fresh air to your unit while burning. A slightly opened window is suffi cient for the purpose.
Hampton H300 Cast Freestanding Woodstove 21 SAFETY GUIDELINES AND W ARNINGS 1) Never use gasoline, gasoline type lantern fuels, kerosene, charcoal lighter fuel, or similar liquids to start or ‘freshen up’ a fi re in your heater . Keep all such liquids well away from the heater while it is in use.
Hampton H300 Cast Freestanding Woodstove 22 OPERA TING INSTRUCTIONS ASH DISPOSAL During constant use, ashes should be removed every few days. The Ash Drawer features a convenient ash drawer for easy removal of ashes. Safety Precautions 1) Do not allow ashes to build up to the loading doors! Only remove ashes when the fi re has died down.
Hampton H300 Cast Freestanding Woodstove 23 MAINTENANCE CREOSOTE When wood is burned slowly , it produces tar and other organic vapours, which when combined with moisture, form creosote. The creosote va- pours condense in the relatively cool chimney fl ue of a slow burning fi re.
Hampton H300 Cast Freestanding Woodstove 24 FRONT DOOR GASKET If th e front door gasket requires replacement 5/8" diameter material must be used. Hampton uses a 5/8" diameter gasket (Part# 936-232). A proper high temperature gasket adhesive is required.
Hampton H300 Cast Freestanding Woodstove 25 P ARTS LIST H300 MAIN ASSEMBL Y Part # Description 1) 220-160 Grill Cast - T op 2) 220-371 Stove T op - Charcoal Grey 220-372 Stove T op - Slate Blue 220-37.
Hampton H300 Cast Freestanding Woodstove 26 P ARTS LIST.
Hampton H300 Cast Freestanding Woodstove 27 P ARTS LIST Part # Description 70) 936-232 5/8" Door Gasket 71) 220-034F Retention Glass T op 72) 220-035F Retention Glass 73) 936-243 7/8" Window.
Hampton H300 Cast Freestanding Woodstove 28 Part # Description 220-960 Firebrick Set 90) 802-157 Brick Partial - 4.5" x 8.5" 91) 802-148 Brick Partial - 4.5" x 4.5" 92) 802-158 Brick Partial - 2" x 8.5" 93) 802-159 Brick Partial - 4.
Hampton H300 Cast Freestanding Woodstove 29 NOTES.
Hampton H300 Cast Freestanding Woodstove 30 NOTES.
Hampton H300 Cast Freestanding Woodstove 31 W ARRANTY Hampton Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility .
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Insta.
デバイスHampton Direct H300の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hampton Direct H300をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHampton Direct H300の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hampton Direct H300の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hampton Direct H300で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hampton Direct H300を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHampton Direct H300の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hampton Direct H300に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHampton Direct H300デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。