Hand Held Productsメーカー5620の使用説明書/サービス説明書
ページ先へ移動 of 180
™ IMAGETEAM™ 2020/5620 Cordless System System Manual.
Disclaimer Hand Held Products, Inc. (“Hand Held Pr oducts“) reserves the right to make changes in specifications and other in formation contained in this document without prior notice, and the reader sh ould in all cases consult Hand Held Products to determine whether any su ch changes have been made.
S tatement of Agency Compliance The IT2020-5B/IT5620 system meets or exceeds the requirements of all applicable standards organizat ions for safe operation. However, as with any electrical equipment, the best way to ensure safe operation is to operate them according to the agency guid elines that follow.
If necessary, the user should consult the dealer or an experienced radio/ television technician for add itional suggestions. The us er may find the following booklet helpful: “Something About Interference.” This is available at FCC local regional offices.
Hand Held Products shall not be liable for use of our product with equipment (i.e., power supplies, personal computer s, etc.) that is not CE marked and does not comply with the Low Voltage Directive.
UL and cUL S tatement UL listed UL1950 and CSA 22 .2 No.950. cUL listed UL1950 and CSA 22.2 No 950. TÜV S tatement TÜV or GS marked to EN60950 and EN60825-1. C-T ick S tatement Conforms to AS/NZS 354 8. C-Tick number: N10410. Mexico Patents Please refer to the IT5620 pa ckaging for patent information.
Required Safety Labels B IT5620.
' ' B 2 0 7 2 X M 5 D H : D I C C F B 2 0 7 2 X M B 3 9 6 1 C I a d a n a C . c n I , s t c u d o r P d l e H d n a H 3 5 1 3 1 Y N , s l l a F s e l e t a e n a k S " a n i h C n i e d a M " 0 4 7 3 5 1 E g n i d n e P s t n e t a P n g i e r o F d n a S U 2 8 6 0 .
i Chapter 1 - Getting Started About This Manual ............................................................... 1-1 Unpacking the System .......................................................... 1-2 Models ............................................
ii Basic Operation of the Cordless System ............................ 1-16 System Conditions ....................................................... 1-17 Communication Between the Cordless System and the Host..........................................
iii Wand Emulation ................................................................. 2-13 Wand Emulation Connection ....................................... 2-13 Wand Emulation Transmission Rate ............................ 2-14 Wand Emulation Polarity .
iv Prefix/Suffix Overview ......................................................... 4-1 To Add a Prefix or Suffix: ............................................ 4-2 To Clear One or All Prefixes or Suffixes: ...................... 4-3 To Add a Carriage Return Suffix to all Symbologies .
v Code 39 ................................................................................. 6-5 Code 39 Start / Stop Characters ....................................... 6-5 Code 39 Check Character ............................................... 6-6 Code 39 Message Length .
vi UPC E0 and UPC E1 .......................................................... 6-21 UPC E0 and UPC E1 Expand ...................................... 6-21 UPC E0 and UPC E1 Addenda Required .................... 6-21 UPC E0 and UPC E1 Addenda Separator .
vii Code 49 ............................................................................... 6-36 Code 49 Message Length ............................................. 6-36 Chapter 7 - Interface Keys Keyboard Function Relationships .....................
viii Resetting the Standard Product Default Settings: All Application Work Groups ................................................ 10-5 Menu Commands ................................................................ 10-6 Terminal Interfaces ...........
IMAGETEAM™ 2020/5620 System Manual 1 - 1 1 Getting Star ted The IMAGETEAM 5620 cordless scanning system consists of one IT2020-5B base and one IT5620 Cordless Linear Scanner. Up to seven scanners may be linked to one base. The IT5620 marks a new performance level for hand held scanners.
1 - 2 IMAGETEAM™ 2020/5620 System Manual • Connection of the Base to an Interface Unpacking the System After you open the shipping carton containing the pr oduct, take the following steps: • Check to make sure everyt hing you ordered is present.
IMAGETEAM™ 2020/5620 System Manual 1 - 3 Cordless System: Main Components About the Battery Use only the Li-ion batte ry packs provided by Hand Held Products. The use of any battery pack not sold by Hand Held Products will void your warranty and may result in damage to your unit.
1 - 4 IMAGETEAM™ 2020/5620 System Manual Battery Recommendations • Batteries are shipped approximately 30 % to 60% charged and should be fully charged for maximum charge capacity. • The battery is a lithium ion cell and can be used without a full charge, as well as can be charged without fully dischargi ng, without impacting the battery life.
IMAGETEAM™ 2020/5620 System Manual 1 - 5 Base Charge Mode In order for the battery to be charged , there must be enough voltage for the circuitry to work.
1 - 6 IMAGETEAM™ 2020/5620 System Manual Linking Scanner to Base When newly shipped or defaulted to fact ory settings, the base and scanner are not linked. Once the scanner is placed into the base, the software automatically links the scanner and the base.
IMAGETEAM™ 2020/5620 System Manual 1 - 7 Single Scanner Operation There are two link modes to accommodate different applications: Locked Link Mode and Open Link Mode. Scan the a ppropriate bar codes included in the Open Link and Locked Link Mode explanations that fo llow to switch from one mode to another.
1 - 8 IMAGETEAM™ 2020/5620 System Manual Multiple Scanner Operation To put the scanner in multiple scanner mode, scan the bar code below. Once you scan this bar code, the scanner is unlinked from the base and must be placed into the base to re-link.
IMAGETEAM™ 2020/5620 System Manual 1 - 9 Changing Scanner Name - via Bar Codes If you wanted set up your scanners wi th names 0001-0007, you may scan the bar codes below. Scan the Reset bar code after ea ch name change and wait for the scanner to re-link to the base before scanning the next bar code to name the next scanner.
1 - 10 IMAGETEAM™ 2020/5620 System Manual Scanner Report Scan the bar code below to generate a re port for the connected scanners. The report indicates the port, work group, scanner name, and address. Application W ork Groups Your cordless system can have up to se ven scanners linked to one base.
IMAGETEAM™ 2020/5620 System Manual 1 - 11 Application W ork Group Selection This programming selection allows you to assign a scanner to a work group by scanning the bar code below. You may then program the settings (e.g., beeper volume, prefix/suffix, data formatter) that your a pplication requires.
1 - 12 IMAGETEAM™ 2020/5620 System Manual Resetting the S tandard Product Default Settings: Current Application W ork Group If you aren’t sure what programming op tions are in your scanner, or you.
IMAGETEAM™ 2020/5620 System Manual 1 - 13 Using the Scanner with Bluetooth Devices The IT5620 scanner may be used either wi th the IT2020-5B base or with other Bluetooth devices. Scanning the No n-Base Bluetooth Connection bar code below allows the scanner to be used with other Bluetooth devices (e.
1 - 14 IMAGETEAM™ 2020/5620 System Manual Note: If you are out of range when you sc an a bar code, you will receive an error beep even if you do not have the al arm set. You receive the error beep since the data could not be communi cated to the base or the host.
IMAGETEAM™ 2020/5620 System Manual 1 - 15 IT5620 LED Sequences and Their Meaning IT2020-5B LED Sequences and Their Meaning The base contains a red LED that indicate s the status of the unit and verifies its communication with the host system and a green LED that indicates scanner battery charge condition.
1 - 16 IMAGETEAM™ 2020/5620 System Manual Note: Charging only occurs with external power applied to the IT2020-5B or 12 volt Host power. Basic Operation of the Cordless System Cordless Base The cordless base provides the link be tween the cordless scanner and the host system.
IMAGETEAM™ 2020/5620 System Manual 1 - 17 Cordless Scanner The cordless scanner enables fast and accurate bar code scanning using a non- contact linear scanner. The scanner is comprised of a linear scanner, a decode/control assembly, and an RF communication module.
1 - 18 IMAGETEAM™ 2020/5620 System Manual Communication Between the Cordless System and the Host The cordless scanner provides immediate f eedback in the form of a “good read” indication (a green LED on the scanner and an audible beep) a fter a bar code is scanned correctly and the base has acknow ledged receiving the data.
IMAGETEAM™ 2020/5620 System Manual 1 - 19 2. Disconnect the keyboard cable from the back of the terminal/ computer. 3. Connect the appropriate interface cable to the base and to the terminal/ computer and keyboard. 4. Turn the terminal/ computer power back on.
1 - 20 IMAGETEAM™ 2020/5620 System Manual Reading T echniques The scanner has a view finder that proj ects a bright red aiming beam that corresponds to its horizontal field of view . The aiming line should be centered horizontally over the bar code; it will not read if the aiming line is in any other direction.
IMAGETEAM™ 2020/5620 System Manual 1 - 21 Note: After you scan one of the codes, po wer cycle the host terminal to have the interface in effect. Keyboard W e dge Connection If you want your system programmed for an IBM PC AT and compatibles keyboard wedge interface wi th a USA keyboard, scan the bar code below.
1 - 22 IMAGETEAM™ 2020/5620 System Manual W and Emulation Plug & Play In Wand Emulation mode, the scanner dec odes the bar code then sends data in the same format as a wand scanner.
IMAGETEAM™ 2020/5620 System Manual 1 - 23 IBM 4683 Ports 5B, 9B, and 17 Interface Scan one of the following “Plug and Play ” codes to program the IT5620 for IBM 4683 Port 5B, 9B, or 17. Note: After scanning one of these co des, you must power cycle the cash register.
1 - 24 IMAGETEAM™ 2020/5620 System Manual Connecting the Base with USB A base can be connected to t he USB port of a computer. 1. Connect the appropriate interface cabl e to the base and to the computer. 2. Program the base for the USB inte rface by scanning the appropriate programming bar code.
IMAGETEAM™ 2020/5620 System Manual 1 - 25 IBM SurePos Scan one of the following “Plug and Play ” codes to program the IT5620 for IBM SurePos (USB Hand Held scanner) or IBM SurePos (USB Tabletop scanner). Note: After scanning one of these co des, you must power cycle the cash register.
1 - 26 IMAGETEAM™ 2020/5620 System Manual USB HID Scan the following code to program the IT5620 for USB HID bar code scanners. Scanning this code changes the terminal ID to 131. USB Com Port Emulation Scan the following code to program th e IT5620 to emulate a regular RS-232- based Com Port.
IMAGETEAM™ 2020/5620 System Manual 1 - 27 Connecting the Base with Serial W edge The IT2020-5B uses TTL signal levels to wedge into an RS-232 serial network. Use only IT2020-5B serial wedge cables to prevent da mage to the base. Refer to Connecting the Base with RS-232 Serial Port on page 2-7 to set the baud rate and communications protocol.
1 - 28 IMAGETEAM™ 2020/5620 System Manual To set up the serial wedge terminal ID, us e the serial terminal ID 050 and follow the instructions on page 2-1 . Make sure that all of the communication parameters match on all of the connec ted devices. Choosing Both sends scanned data to P1 and P2.
IMAGETEAM™ 2020/5620 System Manual 2 - 1 2 T erminal Inter faces T erminal ID If your interface is not a standard PC AT, refer to "Supported Terminals" on page 2-2 through page 2-3 , and locate the Terminal ID nu mber for your PC.
2 - 2 IMAGETEAM™ 2020/5620 System Manual Supported T erminals Te r m i n a l Model(s) T erminal ID DEC VT510, 520, 525 (PC style) 005 DEC VT510, 520, 525 (DEC style LK411) 104 Esprit 200, 400 005 He.
IMAGETEAM™ 2020/5620 System Manual 2 - 3 * Default for IT2020-5B. **It is best to use the Plug and Play bar codes, beginning on page 1-25 to program these interfaces, rather than scanning the terminal ID listed in this table.
2 - 4 IMAGETEAM™ 2020/5620 System Manual Keyboard Country Scan the appropriate country code belo w to program the keyboard for your country. As a general rule, the follow ing characters are supporte.
IMAGETEAM™ 2020/5620 System Manual 2 - 5 Please refer to the Hand Held Products website ( www.handheld.com ) for complete keyboard country support inform ation and applicable interfaces.
2 - 6 IMAGETEAM™ 2020/5620 System Manual Emulate External K eyboar d should be scanned if you do not have an external keyboard (IBM AT or equivalent).
IMAGETEAM™ 2020/5620 System Manual 2 - 7 A utomatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the sy stem is dropping characters. Default = Off Connecting the Base with RS-232 Serial Port 1. Turn off power to the terminal/computer.
2 - 8 IMAGETEAM™ 2020/5620 System Manual All communication parameters between the scanner and terminal must match for correct data transfer through the serial port using RS-232 protocol.
IMAGETEAM™ 2020/5620 System Manual 2 - 9 RS-232 W ord Length: Data Bit s , S top Bits, and Parity Data Bits sets the word length at 7 or 8 bi ts of data per character. If an application requires only ASC II Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits.
2 - 10 IMAGETEAM™ 2020/5620 System Manual RS-232 Handshaking RS-232 Handshaking allows control of da ta transmission from the scanner using software commands from the host device. CTS/RTS operates in mode 2. When this feature is turned Off , no data flow control is us ed.
IMAGETEAM™ 2020/5620 System Manual 2 - 11 The commands to which the scanner responds are listed on page 2-12. The <ESC> is a 1B in he x. A typical command string is y <ESC> x, where “y” is the application work group number, “<ESC> x” is the escape command, and the comma is the terminator .
2 - 12 IMAGETEAM™ 2020/5620 System Manual IT2020-5B Host Escape Commands Command Action <ESC> a Indicate as if successful menu change made <ESC> b Indicate as if unsuccessful menu change made <ESC> 1 Illuminate green LED f or 135 milliseconds (follow ed by at least 70 mSecs .
IMAGETEAM™ 2020/5620 System Manual 2 - 13 W and Emulation W and Emulation Connection The Wand Emulation Connection bar code s should be used if you want to change the terminal ID only , without changing any othe r scanner settings. We recommend using Wand Emulation Plug & Play bar codes to program your scanner to emulate a wand reader.
2 - 14 IMAGETEAM™ 2020/5620 System Manual W and Emulation T ransmission Rate The transmission rate is limited by the te rminal’s ability to receive data without dropping characters. Default = 25 inches/second. W and Emulation Polarity The Polarity can be sent as standard with black bars high, or reversed with white bars high.
IMAGETEAM™ 2020/5620 System Manual 2 - 15 W and Emulation Idle The idle describes the state of the sca nner when no data is be ing transmitted. When in Wand Emulation mode, you must set the scanner’s idle state to match the idle state for the device to which the scanner is connected.
2 - 16 IMAGETEAM™ 2020/5620 System Manual W and Emulation Overall Checksum When this option is turned on, a computed check character is added at the end of the entire message. The check ch aracter is the character which when Exclusive-OR’d with every preceding character of the message yields a result of 0x00 (00H).
IMAGETEAM™ 2020/5620 System Manual 3 - 1 3 Output Scanner Functions Good Read Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a g ood read indication.
3 - 2 IMAGETEAM™ 2020/5620 System Manual Beeper Pitch – Good Read The beeper pitch codes modi fy the pitch (frequency) of the beep the scanner emits on a good read. Def ault = Medium. Beeper Duration – Good Read The beeper duration codes m odify the length of the beep the scanner emits on a good read.
IMAGETEAM™ 2020/5620 System Manual 3 - 3 Number of Beeps – Good Read The number of beeps of a good read can be progr ammed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read.
3 - 4 IMAGETEAM™ 2020/5620 System Manual Scanner T rigger Modes Manual/Serial T rigger , Low Power You can activate the scanner either by pr essing the trigger, or using a serial trigger command (see "Trigger Commands" on page 10-4).
IMAGETEAM™ 2020/5620 System Manual 3 - 5 Note: Scanning zero (0) is the eq uivalent of setting no time-out. If there are no trigger pulls during the “sc anner power time-out timer” interval, the scanner goes into power down mode. Whenever the trigger is enabled, the “scanner power time-out timer” is reset.
3 - 6 IMAGETEAM™ 2020/5620 System Manual Hands Free T ime-Out The Automatic Trigger and Presentation Mo des are referred to as “hands free” modes. If the scanner’s trigger is pu lled when using a hands free mode, the scanner changes to manual trigger mode .
IMAGETEAM™ 2020/5620 System Manual 3 - 7 Centering W indow Use the centering feature to narrow the scanner’s field of view so the scanner reads only the bar code you want. When centering is tu rned on, the scanner only reads codes that intersect or are contained within th e centering window you set up.
3 - 8 IMAGETEAM™ 2020/5620 System Manual Example: If you have two bar codes next to one another and the centering window is set to 40% left edge and 60% right edge, only the bar code that intersects t hat window will be decoded.
IMAGETEAM™ 2020/5620 System Manual 3 - 9 3. Length Specify what length (up to 9999 characters) of data output will be acceptable for this symbology. Scan the four digit data length from the Programming Chart inside the back cover of this manual. (Note: 50 characters is entered as 0050.
3 - 10 IMAGETEAM™ 2020/5620 System Manual Note: This selection is unavailable when the Multiple Symbols Selection is turned on. Output Sequence Example In this example, you are scanning Co de 93, Code 128, and Code 39 bar codes, but you want the scanner to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below.
IMAGETEAM™ 2020/5620 System Manual 3 - 11 41 start character match for Code 39, 41h = “A” FF termination string for first code 6A code identifier for Code 128 9999 code length that must match fo.
3 - 12 IMAGETEAM™ 2020/5620 System Manual Multiple Symbols When this programming selection is turned On , it allows you to read multiple symbols with a single pull of the scanner’s trigger. If you press and hold the trigger, aiming the scanner at a series of symbols, it re ads unique symbols once, beeping (if turned on) for each read.
IMAGETEAM™ 2020/5620 System Manual 4 - 1 4 Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This gr oup of bar code da ta and additional, user-defined data is called a “message string.
4 - 2 IMAGETEAM™ 2020/5620 System Manual T o Add a Prefix or Suffix: Step 1. Scan the Add Prefix or Add Suffix symbol ( page 4-3 ). Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the Appendix A ) for the symbology to which yo u want to apply the prefix or suffix.
IMAGETEAM™ 2020/5620 System Manual 4 - 3 T o Clear One or All Prefixes or Suffixes: You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. When you Clear One Prefix (Suffix), the specific character you select is deleted from the symbology you want.
4 - 4 IMAGETEAM™ 2020/5620 System Manual Suffix Selections Function Code T ransmit When this selection is enabled and f unction codes are contained within the scanned data, the scanner transmits the functi on code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting on page 7-3 .
IMAGETEAM™ 2020/5620 System Manual 4 - 5 Intercharacter Delay An intercharacter delay of up to 495 milliseconds may be placed between the transmission of each character of scanned data.
4 - 6 IMAGETEAM™ 2020/5620 System Manual Interfunction Delay An interfunction delay of up to 495 milliseconds may be placed between the transmission of each segment of the message string.
IMAGETEAM™ 2020/5620 System Manual 5 - 1 5 Data F ormatting Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For example, you can use the Data Format Ed itor to insert characters at certain points in bar code data as it is scanned.
5 - 2 IMAGETEAM™ 2020/5620 System Manual Note: The wildcard for all terminal types is 099. Step 4. Code I.D. In the Appendix A , find the symbology to which you want to apply the data format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside the back cover of this manual.
IMAGETEAM™ 2020/5620 System Manual 5 - 3 hex values for ASCII codes, see ASCII Conversion Chart (Code Page 1252) on page A-2.) F4 Send “xx” character “nn” times (Insert) leaving cursor in current cursor posi- tion.
5 - 4 IMAGETEAM™ 2020/5620 System Manual E4 Replaces up to 15 characters in the da ta string with user specified charac- ters. Replacement continues until the E5 command is encountered.
IMAGETEAM™ 2020/5620 System Manual 5 - 5 Data Formatter When Data Formatter is turned off, the bar code data is output to the host as read (including prefixes and suffixes).
5 - 6 IMAGETEAM™ 2020/5620 System Manual.
IMAGETEAM™ 2020/5620 System Manual 6 - 1 6 Sy m b o l o g i e s Introduction This programming section contains the following menu selections. Refer to Chapter 10 for settings and defaults. All Symbologies If you want to decode all the symbologie s allowable for your scanner, scan the All Symbologies On code.
6 - 2 IMAGETEAM™ 2020/5620 System Manual Message Length You are able to set the valid reading length of some of the bar code symbologies. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error beep.
IMAGETEAM™ 2020/5620 System Manual 6 - 3 Codabar <Default All Codabar Settings> Codabar Codabar S tart / S top Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not tr ansmit Start/Stop characters.
6 - 4 IMAGETEAM™ 2020/5620 System Manual When Check Character is set to V alidate, but Don’t T ransmit , the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data. Codabar Concatenation Codabar supports symbol concatenation.
IMAGETEAM™ 2020/5620 System Manual 6 - 5 Codabar Message Length Scan the bar codes below to chan ge the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 2-60. Minimum Defaul t = 4, Maximum Default = 60.
6 - 6 IMAGETEAM™ 2020/5620 System Manual Code 39, continued Code 39 Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character.
IMAGETEAM™ 2020/5620 System Manual 6 - 7 Code 39, continued Code 39 Append This function allows the scanner to ap pend the data from several Code 39 bar codes together before transmitting them to the host computer.
6 - 8 IMAGETEAM™ 2020/5620 System Manual Note: Trioptic Code must be turned off to scan Code 32 Pharmaceutical codes. Full ASCII If Full ASCII Code 39 decoding is enable d, certain character pairs within the bar code symbol will be interpreted as a single character.
IMAGETEAM™ 2020/5620 System Manual 6 - 9 Code 39 Code Page Code pages define the mapping of char acter codes to characters. If the data received does not display wi th the proper characters, it may be because the bar code being scanned was created using a c ode page that is different from the one the host program is expecting.
6 - 10 IMAGETEAM™ 2020/5620 System Manual When Check Digit is set to V alidate, but Don’t T ransmit , the unit only reads Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data.
IMAGETEAM™ 2020/5620 System Manual 6 - 11 Code 93 < Default All Code 93 Settings > Code 93 Code 93 Message Length Scan the bar codes below to chan ge the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 0-80.
6 - 12 IMAGETEAM™ 2020/5620 System Manual Code 2 of 5 <Default All Code 2 of 5 Settings> Code 2 of 5 Code 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional info rmation.
IMAGETEAM™ 2020/5620 System Manual 6 - 13 IA T A Code 2 of 5, continued IA T A Code 2 of 5 Message Length Scan the bar codes below to chan ge the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-48.
6 - 14 IMAGETEAM™ 2020/5620 System Manual Matrix 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional info rmation. Minimum and Maximum lengths = 1-80. Minimum Defaul t = 4, Maximum Default = 80.
IMAGETEAM™ 2020/5620 System Manual 6 - 15 Code 1 1, continued Code 1 1 Message Length Scan the bar codes below to chan ge the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-80. Minimum Defa ult = 4, Maximum Default = 80.
6 - 16 IMAGETEAM™ 2020/5620 System Manual Code 128, continued ISBT 128 Concatenation In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating critical blood informat ion in a uniform manner. The use of ISBT formats requires a paid license.
IMAGETEAM™ 2020/5620 System Manual 6 - 17 Code 128 Function Code T ransmit By default, Code 128 function codes are not transmitted with Code 128 bar code data. However, if you wish to transmit Code 128 function codes with the bar code data, scan the Function Codes On bar code, below.
6 - 18 IMAGETEAM™ 2020/5620 System Manual T elepen Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional info rmation. Minimum and Maximum lengths = 1-60. Minimum Def ault = 1, Maximum Default = 60.
IMAGETEAM™ 2020/5620 System Manual 6 - 19 UPC A Number System The numeric system digit of a U.P.C. sy mbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. UPC A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC A data.
6 - 20 IMAGETEAM™ 2020/5620 System Manual UPC A Addenda Separator When this feature is on, there is a spac e between the data fr om the bar code and the data from the addenda.
IMAGETEAM™ 2020/5620 System Manual 6 - 21 UPC E0 and UPC E1 Most U.P.C. bar codes lead with the 0 number system. For these codes, use the UPC E0 selection. If you need to read co des that lead with the 1 number system, use the UPC E1 selection. Default = On (UPC E0) and Off (UPC E1).
6 - 22 IMAGETEAM™ 2020/5620 System Manual UPC E0 and UPC E1 Addenda Separator When this feature is on, there is a spac e between the data fr om the bar code and the data from the addenda.
IMAGETEAM™ 2020/5620 System Manual 6 - 23 UPC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data. Default = Off for both 2 Digit and 5 Digit Addenda.
6 - 24 IMAGETEAM™ 2020/5620 System Manual EAN/JAN 13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN 13 data. Default = Off for both 2 Digit and 5 Digit Addenda. EAN/JAN 13 Addenda Required When Addenda Required is set to on, the scanner will only read EAN/JAN 13 bar codes that have addenda.
IMAGETEAM™ 2020/5620 System Manual 6 - 25 Note: If you want to enable or disabl e EAN13 with Extended Coupon Code, refer to UPC-A/EAN-13 with Extended Coupon Code on page 6-20. ISBN T ranslate This selection causes EAN-13 Bookland symbols to be translated into their equivalent ISBN number format.
6 - 26 IMAGETEAM™ 2020/5620 System Manual EAN/JAN 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN 8 data. Default = Off for both 2 Digit and 5 Digit Addenda. EAN/JAN 8 Addenda Required When Addenda Required is set to on, th e scanner will only read EAN/JAN 8 bar codes that have addenda.
IMAGETEAM™ 2020/5620 System Manual 6 - 27 MSI <Default All MSI Settings> MSI MSI Check Character Different types of check characters ar e used with MSI bar codes. You can program the scanner to read MSI bar codes with Type 10 check characters.
6 - 28 IMAGETEAM™ 2020/5620 System Manual MSI Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional info rmation. Minimum and Maximum lengths = 4-48. Minimum Def ault = 4, Maximum Default = 48.
IMAGETEAM™ 2020/5620 System Manual 6 - 29 RSS-14 < Default All RSS-14 Settings > RSS-14 RSS Limited < Default All RSS Limited Settings > RSS Limited * On Off * On Off.
6 - 30 IMAGETEAM™ 2020/5620 System Manual RSS Expanded < Default All RSS Expanded Settings > RSS Expanded RSS Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional info rmation.
IMAGETEAM™ 2020/5620 System Manual 6 - 31 Identifier will be reported as “]C1”. If RSS Emulation is selected, the AIM Symbology Identifier will be reported as “]e0.” Any applic ation that accepts EAN•UCC data can be simplified since it on ly needs to recogniz e one data carrier type.
6 - 32 IMAGETEAM™ 2020/5620 System Manual Korea Post Code <Default All Korea Post Code Settings> Korea Post Code Korea Post Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional info rmation.
IMAGETEAM™ 2020/5620 System Manual 6 - 33 PosiCode A and B You have to have PosiCo de A and B on to read any of the PosiCode symbologies. PosiCode Message Length Scan the bar codes below to chan ge the message length. Refer to Message Length on page 6-2 for additional information.
6 - 34 IMAGETEAM™ 2020/5620 System Manual T rioptic Code Trioptic Code is used for la beling magnetic storage media. Note: If you are going to scan Code 32 Pharmaceutical codes, Trioptic Code must be off.
IMAGETEAM™ 2020/5620 System Manual 6 - 35 Code 16K <Default All Code 16K Settings> Code 16K Code 16K Message Length Scan the bar codes below to chan ge the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 0-160.
6 - 36 IMAGETEAM™ 2020/5620 System Manual Code 49 Code 49 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional inform ation. Minimum and Maximum lengths = 1-81. Minimum Def ault = 1, Maximum Default = 81.
IMAGETEAM™ 2020/5620 System Manual 7 - 1 7 Inter face K eys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all termi nals that can be used with the scanner. Refer to page 2-6 enable Control + ASCII mode.
7 - 2 IMAGETEAM™ 2020/5620 System Manual The last five characters in the Full ASCII “C TRL”+ column ( [ ] 6 - ), apply to US only. The following chart indicates the e quivalents of these five characters for different countries.
IMAGETEAM™ 2020/5620 System Manual 7 - 3 Supported Interface Keys ASCII HEX IBM A T/XT and PS/2 Compatibles, WYSE PC/A T Supported Keys IBM XT s and Compatibles Supported Keys IBM, DDC, Memorex T el.
7 - 4 IMAGETEAM™ 2020/5620 System Manual Supported Interface Keys ASCII HEX IBM, Memorex T elex (102)* Supported Keys Memorex T elex (88)** Supported Keys NUL 00 Reserved Reserved SOH 01 E nter Ente.
IMAGETEAM™ 2020/5620 System Manual 7 - 5 Supported Interface Keys ASCII HEX Esprit 200, 400 ANSI Supported Keys Esprit 200, 400 ASCII Supported Keys Esprit 200, 400 PC Supported Keys NUL 00 Reserved.
7 - 6 IMAGETEAM™ 2020/5620 System Manual Supported Interface Keys ASCII HEX Apple Mac/iMac Supported Keys NUL 00 Reserved SOH 01 Enter/Numpad Enter STX 02 CAPS ETX 03 ALT make EOT 04 ALT break ENQ 0.
IMAGETEAM™ 2020/5620 System Manual 8 - 1 8 Utilities T o Add a T est Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symb ology Chart, included in the Appendix A , page A-1) for the single character code that identifies each symbology.
8 - 2 IMAGETEAM™ 2020/5620 System Manual Scanner Report Scan the bar code below to generate a re port for the connected scanners. The report indicates the port, work group, sc anner name, and address. To assign a name to your scanner, refer to "Menu Command Syntax" on page 10-1.
IMAGETEAM™ 2020/5620 System Manual 8 - 3 Note: Scanning this bar code also causes both the scanner and the base to perform a reset and become unlinked.
8 - 4 IMAGETEAM™ 2020/5620 System Manual.
IMAGETEAM™ 2020/5620 System Manual 9 - 1 9 Visual Menu 2003 V isual Menu 2003 Introduction Visual Menu 2003 provides the ability to configure a Hand Held Products scanning device by connecti ng the scanner to the com port of a PC.
9 - 2 IMAGETEAM™ 2020/5620 System Manual 6. Double click on the Visual Menu 2003.exe file. Follow the screen prompts to install the Visual Menu 2003 program. 7. To start Visual Menu 2003, from the Start Menu click on Programs , Visual Menu 2003 , Visual Menu 2003 .
IMAGETEAM™ 2020/5620 System Manual 10 - 1 10 Serial Programming Commands The serial programming commands can be used in place of the programming bar codes.
10 - 2 IMAGETEAM™ 2020/5620 System Manual Data The new value for a menu setti ng, identified by the Tag and Sub- Tag. Storage A single character that spec ifies the storage table to which the command is applied. An exclamation point ( ! ) performs the com- mand’s operation on the device’s volatile menu configuration table.
IMAGETEAM™ 2020/5620 System Manual 10 - 3 Concatenation of Multiple Commands Multiple commands can be issued within on e Prefix/Storage sequence. Only the Tag, SubTag, and Data fields must be repeated for each command in the sequence.
10 - 4 IMAGETEAM™ 2020/5620 System Manual Example #4: What are the device’s se ttings for all Codabar selections? Enter: cbr?. Response: CBRENA1[ACK], SSX0[ACK], CK20[ACK], CCT1[ACK], MIN2[ACK], MAX60[ACK], DFT[ACK].
IMAGETEAM™ 2020/5620 System Manual 10 - 5 Resetting the S tandard Product Default Settings: Current Application W ork Group If you aren’t sure what programming optio ns are in your scanner, or you.
10 - 6 IMAGETEAM™ 2020/5620 System Manual Menu Commands Selection Setting * Indicates default Serial Command # Indicates a numeric entr y Pag e Base Charge Mode *Automatic BASCHG1 1-5 Full Charge Ra.
IMAGETEAM™ 2020/5620 System Manual 10 - 7 Alarm Sound T ype Base Alarm T ype BASORW 1-14 Scanner Alarm T ype BT_ORW 1-14 Data Accumulation Mode On BA TENA1 1-14 *Off BA TENA0 1-14 F actor y Default .
10 - 8 IMAGETEAM™ 2020/5620 System Manual Baud Rate 300 BPS 232BAD0 2-8 600 BPS 232BAD1 2-8 1200 BPS 232BAD2 2-8 2400 BPS 232BAD3 2-8 4800 BPS 232BAD4 2-8 9600 BPS 232BAD5 2-8 19200 BPS 232BAD6 2-8 .
IMAGETEAM™ 2020/5620 System Manual 10 - 9 W and Emulation T ransmis- sion Rate 10 WNDSPD0 2-14 *25 WNDSPD1 2-14 40 WNDSPD2 2-14 80 WNDSPD3 2-14 120 WNDSPD4 2-14 150 WNDSPD5 2-14 200 WNDSPD6 2-14 W a.
10 - 10 IMAGETEAM™ 2020/5620 System Manual Beeper Duration - Good Read *Normal Beep BEPBIP0 3-2 Shor t Beep BEPBIP1 3-2 LED - Good Read Off BEPLED0 3-2 *On BEPLED1 3-2 Number of Beeps - Good Read *1.
IMAGETEAM™ 2020/5620 System Manual 10 - 11 Centering Centering On DECWIN1 3-7 *Centering Off DECWIN0 3-7 Left of Centering Window *40 DECLFT### 3-7 Right of Centering Window *60 DECRGT### 3-7 Output.
10 - 12 IMAGETEAM™ 2020/5620 System Manual Data Formatter Selections Data Format Editor *Default Data F or mat (None) DFMDF3 5-4 Enter Data Format DFMBK3## 5-4 Clear One Data Format DFMCL3 5-4 Clear.
IMAGETEAM™ 2020/5620 System Manual 10 - 13 Code 39 Star t/Stop Char . * Don’t T ransmit C39SSX0 6-5 T ransmit C39SSX1 6-5 Code 39 Check Char . * No Check Char .
10 - 14 IMAGETEAM™ 2020/5620 System Manual Code 2 of 5 Message Length Minimum (1 - 48) *4 R25MIN## 6-12 Maximum (1 - 48) *48 R25MAX## 6-12 IA T A Code 2 of 5 Default All IA T A Code 2 of 5 Settings .
IMAGETEAM™ 2020/5620 System Manual 10 - 15 ISBT Concatenation *Off ISBENA0 6-16 On ISBENA1 6-16 T elepen Default All T elepen Settings TELDFT 6-17 T elepen *Off TELENA0 6-17 On TELENA1 6-17 T elepen.
10 - 16 IMAGETEAM™ 2020/5620 System Manual UPC E Check Digit Off UPECKX0 6-22 *On UPECKX1 6-22 UPC E Number System Off UPENSX0 6-22 *On UPENSX1 6-22 UPC E 2 Digit Addenda *Off UPEAD20 6-23 On UPEAD2.
IMAGETEAM™ 2020/5620 System Manual 10 - 17 EAN/JAN 8 2 Digit Addenda *Off EA8AD20 6-26 On EA8AD21 6-26 EAN/JAN 8 5 Digit Addenda *Off EA8AD50 6-26 On EA8AD51 6-26 EAN/JAN 8 Addenda Required *Not Req.
10 - 18 IMAGETEAM™ 2020/5620 System Manual RSS Expanded Off RSEENA0 6-30 *On RSEENA1 6-30 RSS Expanded Msg. Length Minimum (4 - 74) *4 RSEMIN## 6-30 Maximum (4 - 74) *74 RSEMAX## 6-30 EAN•UCC Emul.
IMAGETEAM™ 2020/5620 System Manual 10 - 19 Codabloc k F Msg. Length Minimum (1 - 2048) *1 CBFMIN#### 6-34 Maximum (1 - 2048) *2048 CBFMAX#### 6-34 Code 16K Default All Code 16K Settings 16KDFT 6-35 .
10 - 20 IMAGETEAM™ 2020/5620 System Manual.
IMAGETEAM™ 2020/5620 System Manual 11 - 1 11 Produc t Specifications IMAGETEAM 5620 Product Specifications Parameter Specification Dimensions (T ypical): Height 6.2 inches (15.7 cm) Length 5.3 inches (13.5 cm) Width 3.2 inches (8.1 cm) Weight (with battery) 9.
11 - 2 IMAGETEAM™ 2020/5620 System Manual IMAGETEAM 2020-5B Product Specifications Parameter Specification Dimensions (T ypical): Height 3.1 inches (7.9 cm) Length 5.6 inches (14.2 cm) Width 4.3 inches (10.9 cm) Weight 8.8 ounces (250 g) V oltage: DC Barrel 8.
IMAGETEAM™ 2020/5620 System Manual 11 - 3 IMAGETEAM 5620 Depth of Field Minimum Bar Wi d t h Maximum Near Field Minimum Far Field (no ambient lighting) 13 mil 100% UPC 1 in (2.5 cm) 24 in (61 cm) 7.5 mil Code 39 4 in (10 cm) 14 in (36 cm) 10 mil Code 39 2 in (5 cm) 18 in (46 cm) 13 mil Code 39 1 in (2.
11 - 4 IMAGETEAM™ 2020/5620 System Manual S tandard Cable Pinout s Keyboard W edge 10 Pin RJ41 Modular Plug connects to the base 1 2 Cord shield 3 Tied to supply power 4 Supply ground 5 Terminal clock 6 Terminal data 7 Supply power input (Refer to tables on page 11-2 .
IMAGETEAM™ 2020/5620 System Manual 11 - 5 S tandard Cable Pinout s W and Emulation 10 Pin Modular Plug connects to the base 1 2 Cord shield 3 Prog 1 (Tied to supply power for primary cable) 4 Supply ground 5 6 Bar code data output 7 Supply power input (Refer to tables on page 11-2 .
11 - 6 IMAGETEAM™ 2020/5620 System Manual S tandard Cable Pinout s Serial Output 10 Pin RJ41 Modular Plug connects to the base 1 2 Cord shield 3 Prog 1 (Tied to supply power for primary cable) 4 Supply ground 5 Receive data - Serial data to scanner 6 Transmit data - Serial data from scanner 7 Supply power input (Refer to tables on page 11-2 .
IMAGETEAM™ 2020/5620 System Manual 11 - 7 S tandard Cable Pinout s USB 10 Pin Modular Plug connects to the base 1 2 Data + 3 Tied to supply power 4 Supply ground 5 6 7 5 volt supply power input 8 9 .
11 - 8 IMAGETEAM™ 2020/5620 System Manual.
IMAGETEAM™ 2020/5620 System Manual 12 - 1 12 Maintenanc e Maintenance Repairs and/or upgrades are not to be performed on this product. These services are to be performed only by an authorized service center. See "Customer Support" on page 13-1 for further information.
12 - 2 IMAGETEAM™ 2020/5620 System Manual Replacing the IT2020-5B Interface Cable: 1. Turn the power to the host system OFF. 2. Disconnect the base’s cable from the terminal or computer. 3. Turn the base upside down. 4. Pull the connector out while maintaining pressure on the connector release clip.
IMAGETEAM™ 2020/5620 System Manual 12 - 3 If the green LED isn’t illuminated, check that: • The scanner is correct ly placed in the base. • There is external power or 12 volt host power. • Charge mode is turned on. ( See "Base Charge Mode" on page 1-5 ) • The battery is not bad or deeply disc harged.
12 - 4 IMAGETEAM™ 2020/5620 System Manual 1. Scan the sample bar codes in the back of this manual. If the scanner reads the sample bar codes, check that your bar code is readable. Verify that your bar code symbology is enabled (see Chapter 6 ). 2. If the scanner still can’t read the sample bar codes, scan All Symbologies on page 6-1.
IMAGETEAM™ 2020/5620 System Manual 13 - 1 13 Customer Suppor t Product Service and Repair Hand Held Products provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, return the unit to Hand Held Products (pos tage paid) with a copy of the dated purchase record attached.
13 - 2 IMAGETEAM™ 2020/5620 System Manual Online Product Service and Repair Assistance You can also access product servic e and repair assistance online at www.
IMAGETEAM™ 2020/5620 System Manual 13 - 3 This warranty shall extend fr om the time of shipment for the duration published by Hand Held Products for the product at the time of purchase ("Warranty Period").
13 - 4 IMAGETEAM™ 2020/5620 System Manual.
IMAGETEAM™ 2020/5620 System Manual A - 1 Appendix A Symbology Chart Note: “m” represents the AIM modifier character. Refer to International Technical Specification, Symbolog y Iden tifiers, for AIM modifier character details. Note: Prefix / Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry.
A - 2 IMAGETEAM™ 2020/5620 System Manual ASCII Conversion Chart (Code Page 1252 ) Note: This table applies to U.S. style keyboar ds. Certain characters may differ depending on your Country Code/PC regional settings.
IMAGETEAM™ 2020/5620 System Manual A - 3 Dec. Hex Char Dec. He x Char Dec. Hex Char Dec. Hex Char 128 80 € € 160 A0 192 C0 À 224 E0 à 129 81 161 A1 ¡ 193 C1 Á 225 E1 á 130 82 ‚ 162 A2 ¢ .
A - 4 IMAGETEAM™ 2020/5620 System Manual Code Page Mapping of Printed Bar Codes Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting.
.
Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 1234567890 Code 128 9 780330 290951 654 EAN 8 3210 5 456123 8 0 UPC-E.
Sample Symbols Code 93 123456-9$ Code 2 of 5 123456 Matrix 2 of 5 6543210 RSS-14 (01)00123456789012 Code 39 Codabar BC321 A13579B.
.
.
.
Programming Chart A C Save B Discard F E D Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save .
Hand Held Products, Inc. 700 Visions Drive P.O. Box 208 Skaneateles Falls, NY 13153-0208 5620B-SM Rev A 4/05.
デバイスHand Held Products 5620の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hand Held Products 5620をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHand Held Products 5620の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hand Held Products 5620の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hand Held Products 5620で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hand Held Products 5620を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHand Held Products 5620の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hand Held Products 5620に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHand Held Products 5620デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。