SAFETY NOTICE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INST ALL AND USE YOUR NEW ROOM HEA TER. F AILURE TO FOLLOW INSTRUCTIONS MA Y RESUL T IN PROPERTY DAMAGE, BODIL Y INJUR Y , OR EVEN DEA TH. IF THIS HARMAN STOVE IS NOT PROPERL Y INST ALLED, A HOUSE FIRE MA Y RESUL T .
2 INTRODUCTION ........................................................... 3 INST ALLA TION ............................................................. 4 Clearances ................................................................. 4 V enting .......
3 Introduction The Harman Clarity 929BV V ented Gas Heater is a listed gas-red vented room heater tested by Intertek T esting/W arnock Hersey to ANSI standard Z21.
4 In addition to these clearances, adequate accessibil- ity clearance for servicing and proper operation must be maintained. Do not in any way obstruct the combustion air inlets that are located under the heater .
5 VENTING Use Only Appr oved V enting The Clarity gas heater is tested and listed for connection to a 4" (100 mm) listed Class B venting system. If the uni t is i ns tal le d to vent thr oug h an appro ve d maso nr y chimney or a factory-built chimney system, an approved Class B chimney liner must be used.
6 The front is released when levers on the left and right sides are pushed to the rear ASSEMBL Y The Clarity is shipped from the factory with the log set packed inside the rebox.
7 Install the Back Log and Back Brick Panel These two components are installed as a single piece. Rest the back brick panel on the shelf located on the back side of the back log, and center it.
8 Pipe Length Schedule 40 Pipe T ubing, T ype L (Feet) Inside Diameter Outside Diameter RECOMMENDED GAS PIPE DIAMETER NOTE: NEVER USE PLASTIC PIPE. CHECK T O CONFIRM WHETHER YOUR LOCAL CODES ALLOW COPPER TUBING OR GAL V ANIZED PIPE. N.G. L.P . N.G. L.
9 W ARNING: THIS HEA TER IS EQUIPPED WITH A THREE-PRONGED GROUNDING PLUG THA T SHOULD BE PLUGGED DIRECTL Y INTO A PROP - ERL Y GROUNDED RECEPT ACLE. DO NOT CUT OR R EMO VE TH E GR OU ND IN G PR ONG FRO M THE PLUG.
10 MONITORING THE GAS FLAME Periodically , the ames of the Clarity B-V ent Gas Heater should be checked while it is operation. The ames should be relatively well-dened and stable. They should be bright yellow with a blue base where attached to the burner ports.
1 1 •If the knob does not pop up when released, stop and immediately call your service technician or gas supplier . •If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier .
12 Maintenance A qualied service person recommended by your Harman dealer should conduct an annual inspection and maintenance of your Clarity , its venting, and the installa - tion to keep it running safely and efciently . These pro - cedures should be performed only by a qualied service person.
13 The Clarity B-V ent gas heater , when installed, must be electri - cal ly gro un ded i n a cco rd anc e with local co des o r , in th e absen ce of local codes, with the current edition of the National Electri - cal Code, ANSI/NFP A 70 in the United States or the curr ent Canadian Electrical Code CSA 22.
14 Parts List The following replacement parts for your Harman Clarity B-V ent are available from your Harman dealer . ID# Part No. Part 1 1-89-08270 BVG weldment 2 1-10-08262-1 Left wing door 3 1-10-0.
15 Clarity B-V ent - Exploded V iew.
16 40 38 49 37 12 14 13 52 41 44 48 42 43 31 32 33 50 51 Clarity Burner Module - Exploded V iew.
17 Appendix A CONVER TING THE CLARITY B-VENT FROM ONE GAS T O ANOTHER IN THE FIELD NOTE: THE CONVERSION SHALL BE CAR- R I E D O U T I N A C C O R D A N C E W I T H T H E R E - QUIREMENTS OF THE PROVIN.
18 Appendix B DE-RA TING FOR HIGH AL TITUDE For U.S. installations, the Clarity B-V ent is approved for elevations up to 2000 feet using the factory-installed burner injec tors. At elevations abov e 2000 fee t, U.S. codes req ui re a d ecr ea se in the input ratin g by c ha ngi ng t he burn er injectors to a smaller size.
19 Clarity B V ent Gas Heater Specications T ested to ANSI Z21.88-2002, CSA 2.33-M02, CAN/CGA 2.17-M91. NA TURAL GAS PROP ANE Input Rating (Btu/hr) (0-1375 m) 40,000 40,000 Min. Input Rating (Btu/hr) (0-1375 m) 27,000 28,000 Injector Sizes (DMS) (front/center/rear (0-1375 m) 47/56/39 56/71/53 Manifold Pressure (in w .
20 Harman Stove Company warrants its products to be free from defects in material or workmanship, in normal use and ser - vice, for a period of 6 years from the date of sales invoice and for mechanical and electrical failures, in normal use and service, for a period of 3 years from the date of sales invoice.
デバイスHarman Stove Company 929BVの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Harman Stove Company 929BVをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHarman Stove Company 929BVの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Harman Stove Company 929BVの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Harman Stove Company 929BVで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Harman Stove Company 929BVを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHarman Stove Company 929BVの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Harman Stove Company 929BVに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHarman Stove Company 929BVデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。