Inst allation & Operating Manual The Harman FireLuxe Direct V ent Gas S tove With T op Cooking Burner System WARNING: If the information in these in- structions is not followed exactly, a fire or explosion may result causing property dam- age, personal injury or loss of life.
2 AVERTISSEMENT : Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incindie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
3 T ABLE OF CONTENTS IMPOR T ANT SAFETY INFORMA TION 4 S P E C I F I C A T I O N S 5 I N S T A L L A T I O N 6 M A S S A C H U S E T T S R E Q U I R E M E N T S 7 V E N T I N G 8 A S S E M B L Y 1 4 L.
4 IMPORT ANT SAFETY INFORMA TION The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.
5 SPECIFICA TIONS MAIN BURNER Natural Gas Propane (LP) Input Rating-Btu/hr 36000 36000 Min. Input-Btu/hr 23000 23000 Orifice-DMS #34 #50 COOKING BURNER Input Rating-Btu/hr 12000 12000 Min. Input-Btu/hr 3500 3500 Orifice-DMS #52 #58 GAS SUPPLY Manifold Pressure 4.
6 INST ALLA TION MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION Stove to Left Side Wall 6” (150mm) Stove to Corner Wall 6” (150mm) Stove to Right Side Wall 6” (150mm) Stove to Ceiling 30” (760mm) Stove to Rear Wall 6” (150mm) Stove to 10” Deep Mantel 30” (760mm) Max.
7 INST ALLA TION The gas stove is shipped with a flexible connector that has a 1/2” NPT female connection. The gas supply piping should have a separate gas shutoff valve and a 1/8” NPT plugged tapping upstream of the valve.
8 VENTING The FireLuxe Gas Stove has been tested and listed fo r installation with 4” X 6 5/8” Simpson DuraVent GS, AmeriVent Direct, Security Secure Vent and Selkirk DT direct venting components.
9 VENTING Example 2 Fuel = Propane (LP) Vertical Rise = 6 feet Horizontal Run = 8 feet Elbows = 3 Equiv. Horizontal Run = 16 feet (8+4+4) Air Restrictor Setting = C Exhaust Restrictor Setting = 3 C 3 EXHAUST INLET AIR E½ 7 ⅜ Example 3 Fuel = Natural Gas Vertical Rise = 22 feet Horizontal Run = 0 feet Elbows = 0 Equiv.
10 VENTING VERTICAL RISE IN FEET HORIZONT A L RUN IN FEET NA TU RA L GA S VE NT ING IF YOUR VENTING CONFIGURA- TION FALLS ABOVE THIS DOT- TED LINE, SEE PAGE 12.
11 VENTING VERTICAL RISE IN FEET HORIZONT A L RUN IN FEET PROP ANE (LP) GA S VENTING IF YO UR VENTI NG CO NFIG UR A- TION F A LLS ABOVE THIS DOT- TED LINE, SEE PA GE 12.
12 VENTING PLEASE NOTE: If your specific venting configurati on falls in a box in the venting charts (on pages 10 & 11) that is above the dotted line ( ), you must use one of the approved direct vent venting systems that utilizes a stainless steel inner liner.
13 VENT TERMINAL CLEARANCES VENTING Venti ng terminals shall n ot be recesse d into a wall or sid ing..
14 ASSEMBL Y UNPACKING AND PLACING THE FIRELUXE By now, you will have rem oved the shipping carton from the base pallet. The FireLuxe is shipped on spe- cially designed shipping supports that keep the weight of the stove off the legs to avoid damaging them dur- ing transit.
15 ASSEMBL Y LEFT REAR LOG RIGHT REAR LOG LEFT REAR LOG RECESS RIGHT REAR LOG RECESSES LEFT FRONT LOG RECESS RIGHT FRONT LOG RECESS PINS LOGS AND EMBERS Slide the logs and packing out of the firebox and set on the floor. Carefull y unpack each of the four logs and three loose ember pieces.
16 ASSEMBL Y Place the left front log next. Again, there is a recess on the burner top that corresponds to the shape of the flat base of the log. Place the left end of the log in the recess and rest the right end on the left rear log using the illustration below as a guide.
17 ASSEMBL Y When correctly placed, the logs and embers will look like the illustration below. LATCHING DETAIL- PULL FORWARD AND DOWN TO HOOK LATCH OVER GLASS FRAME After the logs and embers have been placed, the next step is to replace the glass panel and frame.
18 ASSEMBL Y It is now time to install the ashlip on the stove front and to install the stove front and stove top. The ashlip is secured to the front using two brackets and four 1/4 – 20 hex head bolts. With the front facing down on a padded surface, align the mounting bosses on th e ashlip with the mounting bosses on the front.
19 ASSEMBL Y The remote control handset is powered by a 9-volt battery. There is a low battery indicator on the handset display panel. To replace the battery, remove the access cover from the rear of the handset and unsnap the old battery. Replace with a high quality long-life alkaline battery and reinstall the cover.
20 ASSEMBL Y The main heating valve battery pack is located at th e center rear o f the stove. A removable valve access panel covers the valve components and simply lif ts up a nd off the stove back. The batteries are located in the control module next to the actual valve.
21 AIR INLET AND EXHAUST OUTLET RESTRICTORS The FireLuxe is equipped with externally adjustable rest rictors for both the inlet air and the exhaust outlet. This makes it possible to fine tune the direct vent sy stem for the specific conditi ons of y our installation.
22 You will now see the two guide pl ates. The guide plates have a pointer that corresponds to a letter scale for the air adjustment and number scale for the exhaust adjustment. These are the letters and numbers that are referenced in the venting charts on pages 10 and 11 and shown in detail in the examples shown on pages 8 and 9.
23 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal in jury or loss of life. THIS APPLIANCE HAS TWO SEPARATE BURNER AND GAS CONTROL SYST EMS.
24 LIGHTING AND OPERA TION 1. To turn the cooking burner off, turn the knob to the OFF, full clockwise position. TO TURN OFF GAS TO MAIN BURN ER 1. Press the OFF button on the remote (if available). 2. Turn the main valve knob to the OFF full clockwise position.
25 LIGHTING AND OPERA T ION COOKING BURNER OPERATION The cooking burner on your FireLuxe functions like a cooking burner on any conventional kitchen range. A battery-powered flame-sensing automatic ignition sy stem lights the burner when y ou depress the control knob and rotate counterclockwise to the High (H) position.
26 LIGHTING AND OPERA TION REMOTE CONTROL HANDSET OPERATION A ND PROGRAMMING Flame Height Adjustment PILOT FLAME ADJUSTMENT The pilot flow is factory set to maximum. The pilot flame should envelope 3/8” to 1/2” of the thermo- couple. See the illustration above.
27 LIGHTING AND OPERA T ION SET OFF UP DOWN Radio Frequency Interf erence A frequency code is preset f or the valve receiver and remote handset, but can b e changed if y ou are experiencing interference with other de- vices.
28 MAINTENANCE A qualified service agency should conduct an annual inspection and maintenance of your FireLuxe includ- ing the overall installation and venting to keep it running safely. The following procedures should be per- formed only by a qualified service person.
29 MAINTENANCE INSPECTING THE VENTING An inspection of both the inner and outer vent pipes and the vent terminal should be made as part of the an- nual service appointment. The venting must have no blockage and be in good repair. The vent manufac- turer’s instructions may provide specific details on vent inspection.
30 P ARTS LIST *This is a quick response thermocouple. Replace it only with Part No. 3-40-09906.
31 HARMAN GOLD W ARRANTY 6 YEAR TRANSFERABLE LIMI TE D WARRANTY (Residential) 1 YEAR LIMITED WARRANTY (Commercial) Harman Stove Company warrants its products to be free from def ects in material or wo.
32 For replacement parts and customer service, contact your Harman Stove dealer. Manufactured b y : HARMAN STOVE COMPANY 352 MOUNTAIN HOUSE ROAD HALIFAX, PA 17032 Ver.
デバイスHarman Stove Company FireLuxe Direct Vent Gas Stove With Top Cooking Burner Systemの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Harman Stove Company FireLuxe Direct Vent Gas Stove With Top Cooking Burner Systemをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHarman Stove Company FireLuxe Direct Vent Gas Stove With Top Cooking Burner Systemの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Harman Stove Company FireLuxe Direct Vent Gas Stove With Top Cooking Burner Systemの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Harman Stove Company FireLuxe Direct Vent Gas Stove With Top Cooking Burner Systemで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Harman Stove Company FireLuxe Direct Vent Gas Stove With Top Cooking Burner Systemを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHarman Stove Company FireLuxe Direct Vent Gas Stove With Top Cooking Burner Systemの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Harman Stove Company FireLuxe Direct Vent Gas Stove With Top Cooking Burner Systemに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHarman Stove Company FireLuxe Direct Vent Gas Stove With Top Cooking Burner Systemデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。