1 R6 INVINCIBLE "RS" OWNERS MANUAL.
2 Contents Manufactur ed by Harman Stove Company 352 Mountain House Road Halifax Pa. 17032 (717) 362-9080 Packing List 3 Installation & Assembly 3 V enting 5 Operation 9 ESP Control 1 2 Maintenanc.
3 Packing List Assembly and Installation Final Assembly Remove parts from ash pan. Install W ooden Door Handle with 1/4 x 20 x 2 1/2 bolt. Install Brass Hopper Knob with 10-32 x 1/2 bolt. Install the two Firebricks on the angle iron behind the burn pot as shown in fig.
4 Installing Place the stove on a noncombustible floor pro- tector and away from combustible walls at least as far as shown in figure 2 and 3. Note that the clear- ances shown are minimum for safety but do not leave much room for access when cleaning or servicing.
5 V enting A combustion blower is used to extract the com- bustion gases from the firebox. This causes a nega- tive pressure in the firebox and a positive pressure in the venting system as shown in fig. 4. The longer the vent pipe and more elbows used in the system, the greater the flow resistance.
6 #2 Preferr ed method This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall. The vertical portion of the vent should be three to five feet high and at least three inches from a combustible wall.
7 #4 Installing into an existing chimney ( US only ) This method provides excellent venting for nor- mal operation. This method also provides natural draft in the event of a power failure. If the chimney condition is questionable you may want to install a liner as in method #7.
8 #6 Installing into an existing fireplace chimney ( US and Canada ) This method provides excellent venting for nor- mal operation. This method also provides natural draft in the event of a power failure. In Canada and some places in the US it is re- quired that the vent pipe extend all the way to the top of the chimney .
9 DO NOT INST ALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT . DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SER VING ANOTHER APPLIANCE. INST ALL VENT A T CLEARANCES SPECIFIED BY THE MANUF ACTURER Mobile home installation should be done in accordance with the Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24.
10 Operation Starting First Fir e Be sure the power cord is plugged into a 120 volt receptacle. This can be verified by the red power light on the control panel. Fill the hopper with pellets, fig. 12. Fill the burn pot with pellets to a level just short of overflowing, fig.
11 Starting a fir e after pr oper Feed Rate is known. Clean burn pot with scraper (supplied). Fill the hopper with pellets. Fill the burn pot with pellets to a level just short of overflowing. Adjust feed rate to proper setting. After you know what feed rate works well, then use that setting.
12 When to use "Stove T emp Mode" In "Stove T emp Mode" the Stove T emp Dial determines the temperature of the stove. Heat output and fuel consumption will remain con- stant. This makes it possible to tell how long a hopper full of pellets will last.
13 ESP CONTROL Feed adjuster Sets the maximum feed rate T est Runs all motors at full speed for two minutes to check operation. After two minutes the stove will go to minimum burn and the blowers will alternate fr om high to low every two minutes to remind you that you are still in "T est Mode".
デバイスHarman Stove Company R6の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Harman Stove Company R6をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHarman Stove Company R6の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Harman Stove Company R6の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Harman Stove Company R6で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Harman Stove Company R6を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHarman Stove Company R6の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Harman Stove Company R6に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHarman Stove Company R6デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。