08/04 34962 Rev G 1 INST ALLA TION & OPERA TING INSTRUCTIONS BC36C, BC36R WOODBURNING FIREPLACE WARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assist ance or additional information, consult a qualified inst aller , service agency or the gas supplier .
2 34962 Rev G 08/04 BC36C/BC36R INST ALLA TION INSTRUCTIONS CAUTION: Do not expose the fireplace to the elements (i.e. rain, etc.) and keep the fireplace dry at all times. W et insula- tion will produce an odor when the fireplace is used. T able of Content s Safety Precautions .
08/04 34962 Rev G 3 BC36C/BC36R INST ALLA TION INSTRUCTIONS DESIGN AND INST ALLA TION CONSIDERA TIONS When selecting a location for your woodburning fireplace, it is important to evaluate a number of considerations. Modern construction techniques can create conditions that may not allow your chimney to draft properly .
4 34962 Rev G 08/04 BC36C/BC36R INST ALLA TION INSTRUCTIONS W ARNING! This fireplace and its component s are designed to be installed and operated as a system.
08/04 34962 Rev G 5 BC36C/BC36R INST ALLA TION INSTRUCTIONS C. SYSTEM COMPONENTS 1. Fireplace Component s Bi-Fold Glass Doors HX3 - Hearth Extension BC10 (for BC36C only) GR16 - Grate FK22 - Fan Kit w.
6 34962 Rev G 08/04 BC36C/BC36R INST ALLA TION INSTRUCTIONS AK22 - Outside Air Kit Fireplace Dimensions (BC36C shown, same as BC36R).
08/04 34962 Rev G 7 BC36C/BC36R INST ALLA TION INSTRUCTIONS 2. Chimney Component s The following pictures show only those chimney components which may be safely used with this fireplace.
8 34962 Rev G 08/04 BC36C/BC36R INST ALLA TION INSTRUCTIONS SL3 - Chimney St abilizer Offset/Return RF370 - Roof Flashing Flat to 6/12 Pitch RF371 - Roof Flashing 6/12 to 12/12 Pitch CB876 Chimney Bracket AS8 Straight Attic Insulation Shield Chimney Sections Firestop Sp acer JB877 Joint Band Ca t a log # A B SL 306 6 in .
08/04 34962 Rev G 9 BC36C/BC36R INST ALLA TION INSTRUCTIONS TR344 Round T ermina- tion Cap ST375 Square T ermination Cap CT35 Chase T op LDS33 (3 ft x 3 ft) LDS46 (4 ft x 6 ft) Decorative Shroud TS345.
10 34962 Rev G 08/04 BC36C/BC36R INST ALLA TION INSTRUCTIONS W ARNING! Do not draw out side air from garage spaces. Exhaust product s of gasoline engines are hazardous.
08/04 34962 Rev G 11 BC36C/BC36R INST ALLA TION INSTRUCTIONS Figure 5 - Framing the Fireplace W ARNING! Do not apply combustible finishing materials over any p art of the black face of this fireplace or a struc- ture fire may result. The black front may only be covered with noncombustible materials such as ce- ramic tile, brick, or stone.
12 34962 Rev G 08/04 BC36C/BC36R INST ALLA TION INSTRUCTIONS Figure 6 - Sidewalls and Surrounds E. CHIMNEY REQUIREMENTS When planning your fireplace location, the chimney construction and necessary clearances must be considered. The fireplace system and chimney components have been tested to provide flexibility in construction.
08/04 34962 Rev G 13 BC36C/BC36R INST ALLA TION INSTRUCTIONS W ARNING! Do not combine offsets to create an offset greater than 30° from vertical. This may create a fire hazard since the natural draft may be restricted. 1. Using Offset s and Returns a.
14 34962 Rev G 08/04 BC36C/BC36R INST ALLA TION INSTRUCTIONS Figure 8 - Chimney Height *Dimensions reflect effective height. T able 2 3. Number of Sections Required T o determine the chimney component s needed to complete your particular installation, follow the step s below: a.
08/04 34962 Rev G 15 BC36C/BC36R INST ALLA TION INSTRUCTIONS F . INST ALLA TION OF FIREPLACE W ARNING! Before st arting, do the following: 1. W ear gloves and safety glasses for protection. 2. Keep hand tools in good condition. Sharpen cutting edges and make sure tool handles are secure.
16 34962 Rev G 08/04 BC36C/BC36R INST ALLA TION INSTRUCTIONS Figure 1 1 Installing the Firestop S pacer CAUTION: Firestop spacers must be used whenever the chimney penetrates a ceiling/floor area.
08/04 34962 Rev G 17 BC36C/BC36R INST ALLA TION INSTRUCTIONS W ARNING! Maintain a minimum of 2 in. air clearance to all parts of the chimney system at all times! Fail- ure to maintain this 2 in. air clearance will cause a structure fire. CAUTION: Inner flue and outer liner sections cannot be disassembled once locked together .
18 34962 Rev G 08/04 BC36C/BC36R INST ALLA TION INSTRUCTIONS Figure 14 - Ceiling/Attic Construction Figure 15 - Air Kit Handle Location 9. Mark the Exit Point of the Roof Locate the point where the chimney will exit the roof by plumbing down to the center of the chimney .
08/04 34962 Rev G 19 BC36C/BC36R INST ALLA TION INSTRUCTIONS Note: Use only a noncombustible material to fin- ish the face of the fireplace below the level of the front standoffs. A noncombustible material such as USG MICORE CV230 Mineral Fiber Board, or USG DUROCK Cement Board is recommended for this purpose.
20 34962 Rev G 08/04 BC36C/BC36R INST ALLA TION INSTRUCTIONS Figure 17 - Factory Built Hearth Extension W ARNING! Hearth extensions are to be installed only as illustrated to prevent high temperatures from occurring on concealed combustible materials.
08/04 34962 Rev G 21 BC36C/BC36R INST ALLA TION INSTRUCTIONS Figure 19 - Position the Hearth Extension 17. Position the Hearth Extension Position and secure the hearth extension over the protective metal strips that have been placed p artially under the fireplace front.
22 34962 Rev G 08/04 BC36C/BC36R INST ALLA TION INSTRUCTIONS G . CONSTRUCTING A CHASE Figure 20 - Chase Constructions Figure 21 - Chase Assembly 1. Materials a.
08/04 34962 Rev G 23 BC36C/BC36R INST ALLA TION INSTRUCTIONS Figure 22 - Installing a TR344 Round T ermination Cap Figure 23 - Installing a TR342 Round T elescoping T ermination Cap 2. Chase T op Construct a chase of desired materials maintaining a minimum 2 in.
24 34962 Rev G 08/04 BC36C/BC36R INST ALLA TION INSTRUCTIONS W ARNING! Never inst all a single wall slip section or smoke-pipe in a chase structure. The higher temperature of this single wall pipe may radiate sufficient heat to combustible chase materials to cause a fire.
08/04 34962 Rev G 25 BC36C/BC36R INST ALLA TION INSTRUCTIONS Note: Save and pass this instruction manual to subsequent home owners. The informa- tion provided is intended to notify and warn them about making unsafe future modifica- tions such as the addition of shelves or the use of unauthorized part s and repairs.
26 34962 Rev G 08/04 BC36C/BC36R INST ALLA TION INSTRUCTIONS W ARNING! Burning wet, unseasoned wood can cause ex- cessive creosote accumulation. When ignited it can cause a chimney fire that may result in a serious house fire. CAUTION: When left closed while burning your fireplace, firescreens and glass doors will be HOT .
08/04 34962 Rev G 27 BC36C/BC36R INST ALLA TION INSTRUCTIONS CAUTION: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liq- uids to start or “freshen up” a fire in this fire- place. Keep all such liquids well away from the fireplace.
28 34962 Rev G 08/04 BC36C/BC36R INST ALLA TION INSTRUCTIONS Figure 27 - Flue Draft Flue draft is measured as negative pressure in the chimney . The amount of negative pressure determines how strong the draft is. The draf t is important because it draws the combustion air into the fireplace and pulls the smoke out of the chimney .
08/04 34962 Rev G 29 BC36C/BC36R INST ALLA TION INSTRUCTIONS I. MAINTENANCE INSTRUCTIONS W ARNING! A chimney fire can permanently damage your chimney system. This damage can only be re- paired by replacing the damaged component part s. Chimney fires are not covered by the Lim- ited Warranty and Buyer Protection Plan.
30 34962 Rev G 08/04 BC36C/BC36R INST ALLA TION INSTRUCTIONS HOMEOWNER’S NOTES.
08/04 34962 Rev G 31 BC36C/BC36R INST ALLA TION INSTRUCTIONS Index A Air Clearance 17, 19 Air Kit 6 Handle Location/Operation 18 Ashes, Disposal of 29 Attic Insulation Shield 8, 17 B Building Codes 4,.
32 34962 Rev G 08/04 HEARTH & HOME TECHNOLOGIES INC. WOODBURNING FIREPLACE Limited W arranty As part of its 20-YEAR BUYER PROTECTION PROGRAM AS P ART OF ITS 20 YEAR BUYER PROTECTION PROGRAM (“PROGRAM”, HEARTH & HOME TECHNOLOGIES INC.
デバイスHearth and Home Technologies BC36Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hearth and Home Technologies BC36Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHearth and Home Technologies BC36Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hearth and Home Technologies BC36Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hearth and Home Technologies BC36Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hearth and Home Technologies BC36Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHearth and Home Technologies BC36Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hearth and Home Technologies BC36Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHearth and Home Technologies BC36Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。