SA VE THESE INSTRUCTIONS www .quadrafire.com This manual contains instructions for Installation, Operation & Maintenance. Please read this entire manual before you install and use your new room heater . Failure to follow instructions may result in property damage, bodily injury , or even death.
R Page 2 September 1, 2008 Cumberland Gap W ood Stove 7006-188E and Welcome to the Quadra-Fire Family ! H earth & Home T echnologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durability , and performance.
Page 3 Cumberland Gap W ood Stove R September 1, 2008 7006-188E SERIAL NUMBER LABEL & LOCA TION .................. 2 PRE-USE CHECKLIST .............................................. 3 LISTINGS & SAFETY NOTICES ............................... 4 I NST ALLA TIONS MA TERIAL NEEDED FOR SAFETY 4 VENTING SYSTEM .
R Page 4 September 1, 2008 Cumberland Gap W ood Stove 7006-188E LISTINGS and SAFETY NOTICES W ARNING ! DO NOT A TTEMPT TO OPERA TE THIS WOODSTOVE WITHOUT READING AND UNDERST ANDING THESE OPERA TING INSTRUCTIONS THOROUGHL Y . F AILURE TO OPERA TE THIS APPLIANCE PROPERL Y MA Y CAUSE A HOUSE FIRE.
Page 5 Cumberland Gap W ood Stove R September 1, 2008 7006-188E DIMENSIONS FRONT VIEW SIDE VIEW VENT SPECIFICA TIONS : Single W all: Six inch (6”) (152mm) diameter , minimum 24 MSG black or blued st.
R Page 6 September 1, 2008 Cumberland Gap W ood Stove 7006-188E B A C1 Non-fuel door side D2 Fuel Door side C2 D1 CLEARANCES TO COMBUSTIBLES (UL and ULC) G (Ceiling) H E1 E2 F1 F2 Fuel door side Non-f.
Page 7 Cumberland Gap W ood Stove R September 1, 2008 7006-188E FLOOR PROTECTION The floor must be non-combustible material, extending beneath heater and to the front/sides/rear as indicated. The floor must be a minimum of 1/2" thickness ("k" value = 0.
R Page 8 September 1, 2008 Cumberland Gap W ood Stove 7006-188E Calculating Alternate Floor Protection Material Thermal Conductivity: k value The k value indicates the amount of heat (in BTU’s) that.
Page 9 Cumberland Gap W ood Stove R September 1, 2008 7006-188E WHEN LOCA TING YOUR STOVE consider safety , convenience, traffic flow , and the fact that the stove will need a chimney and chimney connector .
R Page 10 September 1, 2008 Cumberland Gap W ood Stove 7006-188E The flue collar is reversible for either a top or rear venting installation. The unit is shipped with the flue collar in the top vent position. ACCESSOR Y HORIZONT AL FLUE SHIELD Part HTSHLD-7006 IS REQUIRED ON ALL HORIZONT AL INST ALLA TIONS.
Page 1 1 Cumberland Gap W ood Stove R September 1, 2008 7006-188E T o be sure that your Quadra-Fire stove burns properly , the chimney draft (static pressure) should be approximately -.
R Page 12 September 1, 2008 Cumberland Gap W ood Stove 7006-188E Thimble Assembly: 12" (305mm) of brick separation between clay liner and combustibles. Fireclay liner 5/8" (16mm) Minimum or Equivalent. Sill support Header Wood Stud 2" (51mm) Clearance from chimney wall Fireclay liner 5/8" (16mm) Minimum or Equivalent.
Page 13 Cumberland Gap W ood Stove R September 1, 2008 7006-188E Figure 13B SOLID P ACK CHIMNEY WITH MET AL SUPPORTS AS A THIMBLE Add the 25" (635mm), center-line measurement to the depth measurement of your floor protector .
R Page 14 September 1, 2008 Cumberland Gap W ood Stove 7006-188E First, make the frame for the thimble, ensuring it is no smaller than 14" (356mm) square to maintain a 2" (51mm) air space around the chimney section. Attach the wall spacer to the chimney side of the frame.
Page 15 Cumberland Gap W ood Stove R September 1, 2008 7006-188E When a metal prefabricated chimney is used, the manufacturer ’s installation instructions must be followed precisely .
R Page 16 September 1, 2008 Cumberland Gap W ood Stove 7006-188E Spark Arrestor Cap Roof Flashing Storm Collar Joist Shield/Firestop Listed Chimney Floor Protector Outside Air Kit Connector Outside Air Floor Vent 1 . An outside air inlet must be provided for combustion and must remain clear of leaves, debris, ice and/or snow .
Page 17 Cumberland Gap W ood Stove R September 1, 2008 7006-188E I tems Needed for Installation : 4 in. (102mm) diameter flex pipe in the length as required for your installation; Phillips screwdriver; Silicone sealant; Drills and saws necessary for cutting holes through the wall or flooring in your home.
Page 18 7006-188E R Cumberland Gap Wood Stove BENDING TEMPLA TE STRAIGHT END CUT ENDS Cut Ends Hand Bend #1 Cut Ends Straight End Hand bend #2 Lay the flat diverter on the template with the cut ends at the bottom of the tem- plate. HAND BEND #1 Bend the diverter to match the same degree bend as in the template.
Page 19 Cumberland Gap W ood Stove R September 1, 2008 7006-188E Cut end to the front Straight end to the back Ceramic Blanket Slanted corner Manifold chamber BAFFLE DIVERTER REQUIRED ON ALL HORIZONT AL INST ALLA TIONS 1.
R Page 20 September 1, 2008 Cumberland Gap W ood Stove 7006-188E BURNING PROCESS In recent years there has been an increasing concern about air quality .
Page 21 Cumberland Gap W ood Stove R September 1, 2008 7006-188E FINAL ST AGE The final stage of burning is the charcoal stage. This occurs when the flammable gases have been mostly burned and only charcoal remains. This is a naturally clean portion of the burn.
R Page 22 September 1, 2008 Cumberland Gap W ood Stove 7006-188E NOTE: These are approximate settings, and will vary with type of wood or chimney draft. Due to altitude and other environmen- tal circumstances, this operation information is a guideline only .
Page 23 Cumberland Gap W ood Stove R September 1, 2008 7006-188E CORRECT POSITION INCORRECT POSITIONS Firebox damage due to improper baffle place- ment is not covered by warranty . Operate the wood burning appliance with the baffle in the correct position only .
R Page 24 September 1, 2008 Cumberland Gap W ood Stove 7006-188E OPERA TING INSTRUCTIONS (Cont’d) WOOD SELECTION AND STORAGE CAUTION: DO NOT STORE WOOD CLOSER THAN THE REQUIRED CLEARANCE T O COMBUST.
Page 25 Cumberland Gap W ood Stove R September 1, 2008 7006-188E CHIMNEY CLEANING FORMA TION AND NEED FOR REMOV AL: When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a newly-started or a slow-burning fire.
R Page 26 September 1, 2008 Cumberland Gap W ood Stove 7006-188E 1 . Ensure that the fire is out and the appliance is cool to the touch. 2. Protect a table or counter top with padding or towels. 3. Remove door with broken glass from the appliance by lifting door up and off of the hinges.
Page 27 Cumberland Gap W ood Stove R September 1, 2008 7006-188E MAINTENANCE (Con'd) 1 1 1 1 2 2 3 3 7 4 5 5 5 6 6 5 5 5 5 BRICK REPLACEMENT INSTRUCTIONS Brick Set Part Number: BRICK-7006 T he firebox of your Quadra-Fire Cumberland Gap is lined with high quality firebrick which has exceptional insulating properties.
R Page 28 September 1, 2008 Cumberland Gap W ood Stove 7006-188E 14-1/4" 23.0" 14.0" 5.0" 4-3/8" Ceramic Blanket 10 15 9 8 6 16 3 13 12 4 7 14 17 2 5 18 1 11 19 * Part number list on following page.
Page 29 Cumberland Gap W ood Stove R September 1, 2008 7006-188E Service Parts & Accessories 18 Ash Catcher , Front Matte Black 7006-156MBK 18 Ash Catcher , Front Porcelain (specify color) 7006-15.
R Page 30 September 1, 2008 Cumberland Gap W ood Stove 7006-188E Item No. Accessories Serial No. Part No. Blower , 160 cfm 831-1701 Outside Air Kit 831-1780 Firescreen - Can only be used in Full V ert.
Page 31 Cumberland Gap W ood Stove R September 1, 2008 7006-188E Date of Service Performed By Description of Service Service & Maintenance Log.
R Page 32 September 1, 2008 Cumberland Gap W ood Stove 7006-188E Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the fol.
Page 33 Cumberland Gap W ood Stove R September 1, 2008 7006-188E Noise resulting from minor expansion, contraction, or movement of certain parts is normal and complaints related to this noise are not covered by this warranty .
R Page 34 September 1, 2008 Cumberland Gap W ood Stove 7006-188E This page intentionally left blank..
Page 35 Cumberland Gap W ood Stove R September 1, 2008 7006-188E This page intentionally left blank..
September 1, 2008 Page 36 7006-188E R • Do NOT discard this manual. • Important operating and maintenance instructions included. • Read, understand and follow these instruci- tons for safe installation and operation. • Leave this manual with party responsible for use and operation.
デバイスHearth and Home Technologies CUMBGAP-MBKの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hearth and Home Technologies CUMBGAP-MBKをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHearth and Home Technologies CUMBGAP-MBKの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hearth and Home Technologies CUMBGAP-MBKの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hearth and Home Technologies CUMBGAP-MBKで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hearth and Home Technologies CUMBGAP-MBKを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHearth and Home Technologies CUMBGAP-MBKの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hearth and Home Technologies CUMBGAP-MBKに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHearth and Home Technologies CUMBGAP-MBKデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。