Hearth and Home TechnologiesメーカーEL42の使用説明書/サービス説明書
ページ先へ移動 of 54
1 Owner ’ s Manual Installation and Operation Models: EL36 Series EL42 Series Wood Burning Fireplace DO NOT DISCARD THIS MANUAL NOTICE • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation.
2 Read this manual before installing or operating this replace. Please retain this owner ’ s manual for future reference. Homeowner Reference Information Model Name: Date purchased/installed: Ser.
3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury .
4 W arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer .
5 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor . A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation.
6 1 Listing and C ode A ppro vals NOTICE: This fireplace is tested and approved as a decorative replace. It should not be factored as a primary heat source in residential heating calculations.
7 2 Operat ing Instruc tions W ARNING! DO NOT operate replace before reading and understanding operating instructions. Failure to operate replace according to operating instructions could cause re or injury . User Guide W ARNING Hot glass will cause burns.
8 • The rst three or four res should be of moderate size to allow the oils and binders to be burned from the repla ce and the refractory and paint to cure. Y ou may notice an industrial odor the rst few res. This is considered normal.
9 FULL Y OPEN CORRECT P ARTL Y CLOSED INCORRECT P ARTL Y OPEN INCORRECT FULL Y CLOSED CORRECT Figure 2.2 Operating Positions of Bi-fold Doors W ARNING! Risk of Fire and Smoke! Fireplaces equipped with doors should be operated only with doors fully open or doors fully closed.
10 M. Wood Fuel Hardwood vs Softwood Y our replace performance depends on the quality of the rewood you use. • Seasoned wood contains about 8,000 BTUs per pound . • Hard woods are more dense than soft woods. • Hard woods contain 60% more BTUs than soft woods.
1 1 3 Maintenance and Ser vice Figure 3.1 Chimney & T ermination Cap Cleaning A. Disposal of Ashes Frequency: When they reach bottom of grate By: Homeowner W ARNING! Risk of Fire! Ashes could contain hot em- bers. • Place ashes in a metal container with a tight-tting lid.
12 C. Check Firebox Refractory Frequency: After each ash removal By: Homeowner D. Inspect Grate Frequency: After each ash removal By: Homeowner Inspect grate for: • W arping or sagging 1-1/2 in.
13 4 T roubles hooting Guide Start Fire Problems Possible Cause Solution Can’t get re started Excessive smoke or spillage Burns too slowly Smolders, sizzles Not enough kindling/paper or no kindling/paper Use dry kindling, more paper . Arrange kindling & wood for air movement.
14 5 Get ting Star ted Installer Guide A. T ypical Fireplace System Heatilator • EL36/EL42 • 4044-132 • Rev AD • 7/12 ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ))) ) .
15 Negative pressure results from the imbalance of air avail- able for the replace to operate properly . It can be stron- gest in lower levels of the house.
16 Marginal Location: • Below peak Location NOT recommended: • Not the highest point of the roof • Wind loading possible Multi-level Roofs Windward Leeward Recommended Location: • Above peak R.
17 Before beginning the installation be sure the following tools and building supplies are available: Reciprocating saw Framing material Pliers Non-combustible sealant Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric drill and bits Plumb line Safety glasses Level T ape measure 1/2-3/4 in.
18 6 F raming & Clearances G F E A C Across a corner H As a room divider D 48 in. (1219 mm) minimum A Along a wall A B 5/8 in. (16 mm) all configurations H 1/2 in. (13 mm) min. air space from fireplace to combustible materials. Note: Note: In addition to these framing dimensions, also reference the following sections: • Clearances (Section 6.
19 B. Clearances W ARNING! Risk of Fire! Y ou must comply with all minimum air space clearances to combustibles as specied in Fig- ure 6.2. DO NOT pack required air spaces with insulation or other materials. Heatilator • EL36/EL42 • 4044-132 • Rev AD• 7/12 (roof) (insulation) 0 in.
20 A Fireplace Opening B Outside Dimensions in. 36 41 mm 914 1041 in. 42 47 mm 1067 119 4 Mo del # EL36 EL42 B A 9 3/4 in. [248 mm] 12 in. [305 mm] 12 in. [305 mm] 1 1 1/4 in. [286 mm] FLUSH FRONT 4 in. [102 mm] BRICK FRONT 50° angle 39° angle D. Frame the Fireplace Figure 6.
21 7 Installation of Fi replace CAUTION! Risk of Cuts/Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp. A. Things to Consider • Location of chimney air kit (see Figure 7.4) • Location(s) of outside air kit • Electrical connections and/or wall switch • Gas line piping B.
22 Outlet placed higher than 3 ft below the termination cap Attic space Garage or combustible liquids storage Outlet blocked by snow , leaves, etc. Clear area outside house or in ventilated crawl spac.
23 Outside Air Hood Outside Air Plate Assembly 2 Wire T ies Flexible Duct (not supplied) Figure 7.5 Outside Air Installation E. Install Outside Air Kit • Optional. • Keep duct runs short and straight to minimi ze restricti on. A small dip is acceptable for a cold air trap.
24 Chimney must extend beyond combustible roof structure Maintain minimum height of chimney above roof Additional support for tall chimneys Install roof flashing according to minimum requirements Main.
25 A. Chimney Requirements Measure vertical distances from the base of the replace as shown in Figure 8.2. 20 ft (6.10 m) max. pipe between an offset & return Ceiling Firestop 35 ft (10.67 m) max. straight unsupported chimney height 14.5 ft (4.
26 T able 8.2 B. Using Offsets/Returns • Use an offset/return to bypass overhead obstructions. • An offset and return can be used as a single entity or separated by chimney section(s). W ARNING! Risk of Fire! DO NOT use offset/returns greater than 30°.
27 Figure 8.4 Assembling Chimney Sections • Support the pipe during construction and check to be sure inadvertent loading has not dislodged the chimney section from the replace or at any chimney joint. • Attach a straight chimney section or an of fset to the top of the replace.
28 ROOM ABOVE (non-insulated ceiling) A TTIC ABOVE (insulated ceiling) B A Ceilng firestop from bottom Ceiling firestop from top Note: Use same dimensional lumber for framing ceiling firestop and joists. Figure 8.5 Installing the Ceiling Firestop • Install a ceiling restop whenever chimney penetrates ceiling/oor .
29 3 in. (76 mm) overlap Insert three screws Bend inward 90° Bend remaining tabs to rest against pipe to prevent insula tion from falling in. Figure 8.6 Prepare Attic Insulation Shield Installation of a ceiling restop is required • Refer to Figures 8.
30 Figure 8.9 Ceiling/Attic Construction H. Complete Installation W ARNING! Risk of Fire! Y ou MUST maintain 2 in. (51 mm) air space to insulation and other combustible materials around the chimney system. Failure to do so could cause overheating and re.
31 Slanted Roofs Flat Roofs Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.6 m) above any portion of the roof or adjacent structures within 10 ft (3 m) of the chimney Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.
32 9 Chas e Inst allations Ceiling Firestop Metal Chase T op Round T ermination Cap False Ceiling Insulation in the outside walls of the chase Attic Insulation Shield Chimney Ceiling Firestop T abs False Ceiling False Ceiling Insulation Insulation Figure 9.
33 Slope Downward (1/4 in. per foot minimum) T urn-down Drip Edge Chase 2 in. (51 mm) Collar on Chase T op .018 (26 ga) min. Galvanized Chase T op Figure 9.3 Chase T op Construction B. Install Fireplace & Chimney Install as per Sections 7 and 8. Heatilator • EL36/EL42 • 4044-132 • Rev AD• 7/12 C.
34 D. Install T ermination Cap Install the chimney sections up through the chase enclo- sure. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line to prevent leaks.
35 Heatilator • EL36/EL42 • 4044-132 • Rev AD• 7/12 Chimney Pipe Chase T op T ermination Cap Chase Collar 2 in. (51 mm) Minimum Height T ermination cap pipe and chimney section must overlap 1-1/2 in. (38 mm). Place waterproof sealer under each flange of the termination cap and on top of each screw to help prevent leaks.
36 3 in. (76 mm) tall legs Ø 17 1/2 in. (444.5 mm) Round Hole to fit over cap Length x Width to fit inside shroud Figure 10.1 Radiation Shield 1 0 Shrouds • Chase top shrouds may be eld constructed where permitted by regional building codes. W ARNING! Risk of Fire! Shrouds must be constructed as specied.
37 3 in. (76 mm) Min. Opening Height Min. Base Dim Min. Height above radiation shield Min. Base Dim 3 in. (76 mm) Min. Radiation Shield Height from top of Chase Min. Opening Width Figure 10.3 Mailbox Style Shroud Dimensions Minimum Opening Height Minimum Base Dimension Min.
38 1 1 Finis hing A. Non-Combustible Materials • Materials which will not ignite and burn, composed of any combination of the following: - Steel - Iron - Brick - T ile - Concrete - Slate - Glass - Plasters • Materials reported as passing ASTM E 136, Standard T est Metho d for Behav ior of Metal s, in a V ertic al T ube Furnace at 750° C B.
39 I M P O R TA N T ! H e a r t h e x t e n s i o n d e s i g n m u s t b e determined befo re installatio n of replac e. Floor Non-combustible Framing Material Non-combustible Finishing Material Protective Metal Hearth Strips 1/2 in. Micore or equivalent insulation Non-combustible Material Figure 1 1.
40 Non-combustible Finishing Materials Figure 1 1.5 Raised Platform Hearth Extension-Finishing Materi- als Non-combustible Sealant After completing the framing and applying the facing materials over the framing, a bead of non-combustible sealant must be used to close off any gaps at the top and sides between the replace hearth.
41 D. Finishing Material Refer to Sections 1 1.A. and Sections 1 1.B. for combus- tible/non-combustible materials. Refer to Figure 1 1.7 for non-combustible zone. W ARNING! Risk of Fire! Y ou must maintain clearances. • Use only non-combustible framing material below standoffs.
42 E. Combustible Mantel • Refer to shaded areas of Figure 1 1.9 for the location and dimensions of a combustible mantel. • A combustible mantel may be positioned no lower than 12 in. (305 mm) above the top of the replace opening. • A combustible mantel may have a maximum depth of 12 in.
43 F . Sidewalls/Surrounds • Adjacent combustible sidewalls must be located a minimum of 12 in. (305 mm) from the replace opening. • Combustible or non-combustible mantel legs, surrounds and stub walls may be constructed per Figure 1 1.10. A Fireplace Opening B Outside Dimensions in.
44 Firebox Repack insulation knockout Combustible materials Maintain air clearance to combustibles. Gas line Combustible materials may be located at zero clearance to gas line beyond 4 in. (102 mm) from fireplace side. Gas line 1 1/2 in. (38 mm) air space around pipe Refractory Seal with fireplace mortar or non-combust- ible sealant 4 in.
45 1 3 Reference Materials A. Fireplace Dimensions A 21 in. (533 mm) 7-1/2 in. (191 mm) 14-1/8 in. (359 mm) 18-3/4 in. (476 mm) 21 in. (533 mm) 7-1/2 in. (191 mm) 9-1/4 in. (235 mm) 7-1/2 in. (191 mm) Gas Knockout Outside Air 9-1/4 in. (235 mm) Gas Knockout 7-1/2 in.
46 B. Optional Components 16 in. (406 mm) 52 in. (1321 mm) 1/2 in. (13 mm) 20 in. (508 mm) 66 in. (1676 mm) 1/2 in. (13 mm) HX3 Hearth Extension HX4 Hearth Extension Bifold Glass Doors DM1036, DM1042 AK24 Outside Air Kit ID4 Insulated Duct UD4 Uninsulated Duct 42 in.
47 C. Chimney Components The following pictures show only those chimney components which may be safely used with this replace. ID4 Insulated Duct UD4 Uninsulated Duct 42 in.
48 TR-TVK TR T op V ent Kit Heatilator • EL36/EL42 • 4044-132 • Rev AD • 7/12 A B 14-1/2 in. (368 mm) Ceiling Firestop Assembled Diameter: 14 1/2 in./368 mm Height: 24 in./610 mm AS8 Straight Attic Insulation Shield 10-1/2 in. (267 mm) CB876 Chimney Joint Band RF371 Roof Flashing RF370 Roof Flashing Catalog # A B FS338 0-deg.
49 A B C D LDS33/LDS46 Decorative Shroud E D A C B LDS-BV Decorative Shroud Catalog # A B C D in. mm in. mm in. mm in. mm LDS33 36 914 36 914 8.5 216 1 1 279 LDS46 48 1219 72 1829 8.
50 EL36 ELEMENT Woodburning Fireplace 9 15 18 17 14 16 13 3 1 4 5 6 7 2- Damper Kit 8 12 19 (Air Handle) 10 1 1 1Piece Rod 2 Piece Rod Part number list on following page.
51 D. Service Parts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
52 9 15 18 17 14 16 13 3 1 4 5 6 7 2- Damper Kit 8 12 19 (Air Handle) 10 1 1 1Piece Rod 2 Piece Rod Service Parts Diagram EL42 Beginning Manufacturing Date: Jan 2005 Ending Manufacturing Date: Active ELEMENT Woodburning Fireplace D. Service Parts Part number list on following page.
53 D. Service Parts (continued) D. Service Parts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
54 – NOTES – E. Contact Information DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation.
デバイスHearth and Home Technologies EL42の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hearth and Home Technologies EL42をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHearth and Home Technologies EL42の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hearth and Home Technologies EL42の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hearth and Home Technologies EL42で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hearth and Home Technologies EL42を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHearth and Home Technologies EL42の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hearth and Home Technologies EL42に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHearth and Home Technologies EL42デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。