Heat & GloメーカーEverestの使用説明書/サービス説明書
ページ先へ移動 of 29
Heat & Glo • Everest • 750-900 Rev . o • 10/08 1 Model: Everest • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 2 ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! Safety and W arning Information ! ! DO NOT place furniture or any other combustible household objects within 36 inches of the fi replace front. Any safety screen or guard removed for servicing must be replaced before operating this appliance.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 3 T able of Contents Safety and W arning Information . .................................... 2 Service Parts Lists . .......................................................... 4 Section 1: Approvals and Codes .
Heat & Glo • Everest • 750-900 Rev . o • 10/08 4 Service Parts Diagram Service Parts EVEREST Beginning Manufacturing Date: Aug. 2000 Ending Manufacturing Date: ______ 7 8 9 10 11 12 13 14 15 Part number list on following page.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 5 Service Parts List EVEREST IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
Heat & Glo • Everest • 750-900 Rev . o • 10/08 6 2 3 3 5 4 6 10 9 8 11 17 18 19 V alve Assembly Parts List 1 2 3 3 4 5 6 7 8 9 10 11 12 13 14 15 16 IPI V alve Assembly Post Serial #5000 Standing Pilot V alve Assembly Pre Serial #5000 Service Parts EVEREST Beginning Manufacturing Date: Aug.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 7 Installation Codes The fi replace installation must conform to local codes. Before installing the fi replace, consult the local building code agency to ensure that you are in compliance with all applicable codes, including permits and inspections.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 8 2 Getting Started Introducing the Heat & Glo Gas Fireplaces Heat & Glo direct vent gas fi replaces are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 9 Figure 1. Diagram of the Everest TOP ST ANDOFFS TOP VENT COLLARS TRIM DOOR RA TING PLA TE AND LABELS GAS CONTROLS ELECTRICAL ACCESS GAS LINE ACCESS Ø8 (203.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 10 3 Installing the Fireplace Step 1. Locating the Fireplace The diagram below shows space and clearance require- ments for locating a fi replace within a room.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 11 Figure 5. V ent Components and T erminations Step 3. Installing the V ent System A. V ent System Approvals These models are approved to use D VP-series direct vent pipe components and terminations.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 12 STRAIGHT UP VERTICAL VENTING V (FT .) 40’ MAX. (12.4 M) Figure 6. Straight Up V ertical V enting V CAP.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 13 Figure 7. V enting with One 90° Elbow NOTE: If a 90º elbow is fi rst attached to the unit, the maximum horizontal run is 3 feet (914 mm).
Heat & Glo • Everest • 750-900 Rev . o • 10/08 14 V H + H 1 1’ MIN. (305 mm) 10’ MAX. (3.1 m) 2’ MIN. (610 mm) 15’ MAX. (4.65 m) 4’ MIN. (1.22 m) 20’ MAX. (6.2 m) V+H+H 1 = 40’ MAX. (12.4 m) H+H 1 = 20´ MAX. (6.2 m) V+V 1 +H = 40’ MAX.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 15 V H H 1 V 1 V H H 1 V 1 Figure 9. V enting with three 90° elbows VENTING WITH THREE (3) 90° ELBOWS V + V 1 H + H 1 1’ MIN. (305 mm) 10’ MAX. (3.1 m) 2’ MIN. (610 mm) 15’ MAX. (4.65 m) 4’ MIN.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 16 Figure 10. V ertical Baf fl e 1. Attach the First V ent Component to the Starting Collars T o attach the fi rst vent component to the star.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 17 Figure 1 1 ! DI RECTI ON UP HEAT S HI ELD COMBUSTI BLE S URF ACE 90 EL BO W 0 Figure 12 CORRECT INCORRECT COMBUSTIBLE SURF ACE HEA T SHIELD 3“ MIN. (76 MM) 3. Install Support Brackets Refer to Cinch Pipe and T ermination Cap installation in- structions.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 18 For Vertical Runs - One ceiling fi restop is REQUIRED at the hole in each ceiling through which the vent passes. T o install fi restops for vertical runs that pass through ceilings: • Position a plumb bob directly over the center of the verti- cal vent component.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 19 Figure 17. T rapezoid T ermination Cap 7-1/4 in. (184 mm) ! WARNING: VENTING TERMINALS SHALL NOT BE RECESSED INTO A WALL OR SIDING. VENT TERMINATION CLEARANCES MUST BE FOLLOWED TO AVOID FIRE DANGER.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 20 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 18. Minimum Clearances for T ermination A = 12 inches................. clearances above grade, ver anda, porch, deck or balcony B = 12 inches.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 21 For V ertical T erminations - T o locate the vent and install the vent sections: • Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 22 ! Step 4. Positioning, Leveling, and Securing the Fireplace The diagram below shows how to properly position, level, and secure the fi replace. ! ! Figure 20. Proper Positioning, Leveling, and Securing of a Fireplace Figure 21.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 23 Figure 22. Gas Supply Line • At the gas line access hole, use insulation to re-pack the space around the gas pipe. • Insert insulation from the outside of the fi replace and pack the insulation tightly to totally seal between the pipe and the outer casing.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 24 Step 8. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF YOU ARE ABSENT FOR EXTENDED TIME PERIODS. THIS WILL PREVENT ACCIDENT AL FIREPLACE OPERA TION.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 25 Step 9. Finishing The following diagram shows the minimum vertical and corresponding maximum horizontal dimensions of fi replace mantels or other combustible projections above the top front edge of the fi replace.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 26 Step 10. Installing T rim, Logs and Ember Material Installing the T rim Combustible materials may be brought up to the speci fi ed clearances on the side and top front edges of the fi replace, but MUST NEVER overlap onto the front face.
Heat & Glo • Everest • 750-900 Rev . o • 10/08 27 Step 1 1. Before Lighting the Fireplace Before lighting the fi replace, be sure to do the following: Remove all paperwork from underneath the fi replace. Review safety warnings and cautions • Read the Safety and Warning Information section at the beginning of this Installers Guide .
Heat & Glo • Everest • 750-900 Rev . o • 10/08 28 4 Maintaining and Servicing Y our Fireplace Fireplace Maintenance Although the frequency of your fi replace servicing and maintenance will .
Heat & Glo • Everest • 750-900 Rev . o • 10/08 29 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .heatnglo.com Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
デバイスHeat & Glo Everestの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Heat & Glo Everestをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHeat & Glo Everestの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Heat & Glo Everestの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Heat & Glo Everestで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Heat & Glo Everestを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHeat & Glo Everestの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Heat & Glo Everestに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHeat & Glo Everestデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。