1 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 Owner ’ s Manual Installation and Operation W ARNING: If the in for matio n in th es e ins truct ions is no t fo llo wed exa ctly, a r e or e xpl osio n ma y re sul t ca usi ng pro pe rty dam age, pers ona l i njury , or de ath .
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 2 PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING THIS APPLIANCE. IMPORT ANT : Read all instructions carefully before starting installation. Failure to follow these installation instructions may result in a possible re hazard and will void the warranty .
3 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Se.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 4 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
5 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 = Contains updated information. 13 Finishing A. Framing and Finishing Instructions . . . . . . . . . . . . . . . . . 57 B . M a n t e l P r o j e c t i o n s ...........................
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 6 AUSTRALIAN W ARRANTY INFORMA TION W arranty information in the attached manual is for international markets, not Australia.
7 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 W arranty Period Heat & Glo Manufactured Appliances and V enting Components Covered Parts Labor Gas Wood Pellet EP A Wood Coal Electri.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 8 • Non Heat & Glo venting components, hearth components or other accessories used in conjunction with the appliance. • Any part of a pre-existing replace system in which an insert or a decorative gas appliance is installed.
9 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 A. Appliance Certication 1 Listing and C ode App ro vals C. Gas Pressure Requirements Pressure requirements for SOHO-N-AUB replace are shown in table below .
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 10 Figure 2.1 General Operating Parts DECORA TIVE DOORS (NOT SHOWN) SECTION 2.D. FIXED GLASS ASSEMBL Y (NOT SHOWN) SECTION 9.B. MANTEL SECTION 5.D HEARTH CLEAR SP ACE SECTION 2.C. GRA TE 2 Operat ing Instruc tions User Guide B.
1 1 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 C. Clear Space W ARNING! DO NOT place combustible objects in front of the replace or block louvers. High temperatures may start a re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 12 H. Lighting Instructions (IPI) 1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. 2. Wait ve (5) minut es to clea r out any g as.
13 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 Not e: If t he mod ule is in LOCK- O UT mod e, re set ting t he cir cuit br eaker to the ap plian ce wi ll also r eset the m odul e. Figure 2.3 Control Module I. Control Module Operation 1.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 14 J. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the replace off and allow it to completely cool.
15 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle xed glass assembly with care.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 16 B. Maintenance T asks-Qualied Service T echnician T o prevent inadvertent burner operation while servicing this appliance: • Unplug DC regulator from junction box. • Remove batteries from battery pack (if installed).
17 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 Burner Ignition and Operation Frequency: Annually By: Qualied Service T echnician T ools needed: Protective gloves, vacuum cleaner , whisk broom, ashli ght, vo ltmeter , inde xed dri ll bit set, and a manometer .
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 18 A. T ypical Appliance System NOTICE: Illustrations and photos reect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.
19 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside of the building.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 20 5 F raming and C learances A. Selecting Appliance Location Whe n sele cti ng a loca tio n for the appl ian ce it is imp ort ant to con sid er the re qui red cl ear anc es to wal ls (see Figu re 5.
21 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 22 D. Mantel and W all Projections W ARN ING ! Ri sk of Fir e! C om ply wi th al l m in imu m cle ar - an ces as spe ci ed. Fr ami ng or ni shi ng mat eri al clo ser th an th e mi nim ums lis ted mu st be co ns tru cte d en tir ely of no n- co mbu sti ble ma te ria ls (i.
23 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 A. V ent T ermination Minimum Clearances 6 T er mination Locations Fire Risk. Maintain vent clearance to combustibles as specied. • DO NOT pa ck air spa ce with insul atio n or other materials.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 24 Figure 6.3 Minimum Clearances for T ermination NOTES: 1. All distances are measured vertically or horizontally along the wall to a point in line with the nearest part of the terminal. 2. Prohibited area below electricity meter or fuse box extends to ground level.
25 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 7 V ent Information and Diagrams Figure 7.1 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies SLP venting systems. Refer to Section 16.C for vent component information.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 26 T op V ent - Horizontal T ermination Figure 7.3 H 2 H 1 V 1 INSTALLED HORIZONTALLY Figure 7.4 One Elbow T wo Elbows V 1 H 1 V 1 Minimum H 1 + H 2 Maximum Elbow only Not Allowed 1 ft. 305 mm 2 ft.
27 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 T op V ent - Horizontal T ermination - (continued) Figure 7.5 Three Elbows V 1 Minimum H 1 Maximum V 2 Minimum H 2 Maximum 6 in. 152 mm 1 ft. 305 mm 1 ft. 305 mm 1 ft. 305 mm 1 ft. 305 mm 2 ft.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 28 T op V ent - V ertical T ermination This model is approved to use SLP Series ue pipe com- ponents. A SLP-TVHW vertical Termination Cap must be used to terminate ue systems in a vertical position.
29 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 T op V ent - V ertical T ermination - (continued) No Elbow Figure 7.7 V 1 = 38 ft. Max. (1 1.58 m) V 1 = 3 ft. Min. (914 mm) VERTICAL TERMINA TION BAFFLE N o t e : T h e v e r t i c a l t e r m in a t i o n b a ff l e s h o u l d b e u s e d f o r r u n s o f 1 0 f t .
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 30 Figure 7.8 Flue Components and T erminations MODEL SOHO-N-AUB FLUE TERMINA TION APPROV ALS SLP-TRAP2 HORIZONT AL TERMINA TION CAP SLP-TVH.
31 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 T op V ent - V ertical T ermination - (continued) No Elbow Figure 7.9 Figure 7.10 T wo Elbows V 1 = 38 ft. (1 1.58 m) Maximum V 1 V 1 V 2 H 1 V 1 Minimum H 1 Maximum Elbow only 1-1/2 ft. 457 mm 1 ft.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 32 Figure 7.1 1 T op V ent - V ertical T ermination - (continued) Three Elbows V 2 H 2 V 1 INSTALLED HORIZONTALLY H 1 V 1 Minimum H 1 + H 2 Maximum 1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 mm 3 ft.
33 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 34 Figure 8.4 Installing the Attic Shield 3 F ASTENERS PER SIDE INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP INST ALLED BELOW CEILING CEILING FIRESTOP INST ALLED ABOVE CEILING C.
35 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. An atti c shie ld cons tru cte d of 26 ga uge min imu m meta l that ext end s at l eas t 2 in .
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 36 A. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation.
37 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 Figure 9.2 Fixed Glass Assembly GLASS ASSEMBL Y LA TCHES (BOTH BOTTOM AND TOP) GLASS ASSEMBL Y T AB GLASS CLIP POST B. Covers Removal For Servicing Control Compartment Access Door • Lift the lower door up and out to access the gas controls.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 38 1 0 Installing V ent P ipe ( SLP P ipe ) Figure 10.2 High T emperature Silicone Sealant A. Assemble V ent Sections T o attach the rst vent component to the starting collars of the appliance: • Lock the vent components into place by sliding the pipe section onto the collar .
39 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 Figure 10.5 Securing V ertical Pipe Sections Figure 10.6 Securing Horizontal Pipe Sections B. Assemble Slip Sections • Slide the inner ue of the slip section into the inner ue of the pipe section and the outer ue of the slip section over the outer ue of the pipe section.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 40 D. D i sa ss em bl e V en t Se ct ion s • Rotate either section (see Figure 10.7) so the seams on both pipe sections are aligned as shown in Figure 10.8. • Pull carefully to separate the pieces of pipe.
41 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 10 in. (254 mm) 10 in. (254 mm) INTERIOR WALL SHIELD F . Install Firestops For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the ue passes.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 42 Figure 10.14 V enting through the Wall • The termin atio n kit shou ld pas s throu gh the wall rest ops from the exterior of the building. • Adjust the termination cap to its nal exterior position on the building and interlock the ue sections.
43 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 I. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.16) to determine the length of pipe to extend through the roof. • Slide the roof ashing over the pipe sections extending through the roof as shown in Figure 10.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 44 CAULK J. Assemble and Install Storm Collar CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. • Connect both halves of the storm collar with two screws (see Figure 10.
45 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 1 1 Gas Information A. Gas Pressure Requirements Pressure requirements for SOHO-N-AUB replaces are shown in below . T wo taps are provided on the front of the gas valve for a test gauge connection to measure the inlet and outlet pressures.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 46 Figure 1 1.1 The gas is introduced to the appliance on the left hand side. See Figure 1 1.1. After the gas pipe installation is complete, check carefully all gas conne ctio ns for leaks with a comme rcia lly- avai lab le, noncorrosive leak check solution.
47 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 1 2 Elect rical Infor mation Figure 12.1 IPI Wiring Diagram /RC300AU A. Wiring Requirements NOTICE: This appliance must be installed by a qualied electrician in accordance with the relevant national and local regulations.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 48 BLUE BROWN GREEN/ YELLOW BROWN GREEN/YELLOW BLUE Figure 12.2 D. Blower Use of the fan requires that the Junction Box (factory installed) be connected to 220-240 V AC service before permanently enclosing the replace.
49 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 Not e: If the m odu le is in LOC K- OUT m ode, re set tin g the cir cuit br eaker to the ap plian ce wi ll also r eset the m odul e. Figure 12.4 Control Module E. Control Module Operation 1.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 50 Hearth & Home T echnologies disclaims any responsibility for , and the warranty will be voided by , the following actions: • Installation and use of any damaged system component. • Modication of the system component.
51 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 5. Close the housing door . See Figure 12.8. 4. Plac e r emo te con tro l i nsid e hou sing . See Fig ure 1 2.7. Figure 12.7 Remote in Housing Installation of Remote Control Housing CAUTION! Risk of Fire! DO NOT install damaged or modied components .
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 52 Figure 12.8 Mounting Remote Control Housing AUX300CE Module Installation • In ser t the 4 ho le har nes s fro m the AUX 30 0C E mod ul e int o the 4 pin pl ug on the con trol modu le. See Figur e 12 .
53 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 Function Buttons Menu Select V V Use POWER button to turn the unit on and off. Use MENU but ton to di spl ay the men u fun cti ons . Onl y func tio ns tha t can be acti vat ed wil l be dis pla yed .
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 54 About ON Mode • All functions can be accessed when the remote control is in the ON mode.
55 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 Adjusting Thermostat • Press the MENU button to activate the menu. • Using the UP and DOWN arrows highlight the THERMO icon and press SELECT . • Use the UP and DOWN arrows to turn the THERMO ON or OFF , then press SELECT (the SET TEMP will start blinking).
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 56 Frequently Asked Questions/T roubleshooting Symptom Possible Cause Corrective Action Remote control will not transmit Batteries V erify batteries are functional and installed correctly . Remote control is in Child Lock mode Disengage Child Lock mode.
57 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 1 3 F inishi ng A. Framing and Finishing Instructions W ARN ING ! Ri sk of Fi re ! Co mp ly wi th all mi nim um c le ar - an ces to co mbu sti ble s as sp ec ie d.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 58 A. Remove Fixed Glass Assembly See Section 9.B. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the rebox or underneath in the control cavity .
59 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 E. Log Placement Instructions Log Assembly: LOGS-SOHOCE CAUTION: Logs are fragile. Carefully remove the logs from the packaging. 2 1 Step 1. Place Log #1 (SRV21 1 1-700) against rear right tab with its slot over center locating tab.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 60 1. Remove the front and glass from the unit and set aside. Remove the logs (if installed) from the unit and either discard or save for later use. 2 . F o ld d ow n th e lo g lo ca t in g ta bs ( if be nt up ) on th e ba se p an s o th ey a re p a ra ll el wi th t h e bu rn er .
61 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 1 5 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 62 Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot ame has been lit, ame rectication has not occurred.
63 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 1 6 Reference Mater ials A. Appliance Dimension Diagram Di men si on s a re a ctu al ap pl ian ce d ime nsi on s. Us e fo r r efe re nc e o nly . For f ra min g di men sio ns a nd cle ar an ces r ef er to Se ct ion 5 .
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 64 B. Maintenance T asks Inspect Maintenance T asks Doors 1. Inspect for scratches, dents or other damage and repair as necessary . 2. V erify no obstructions to airow . 3. V erify maintenance of proper clearance to combustible household objects.
65 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 Effective Height/ Length SLP-PIPE SLP-HVS Horizontal Pipe Support SLP-FS Ceiling Firestop SLP-WS W all Shield Firestop Figure 16.2 SLP Series V ent Components C. V ent Components Diagrams 8-3/4 in.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 66 SLK-SNKD Snorkel T ermination Cap SLP-TVHW V ertical T ermination Cap SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-DCF-BK Ceiling Firestop Black SLP-WT -BK W all Thimble-Black B. V ent Components Diagrams (continued) Cap Shield DRC-RADIUS 13-7/8 in.
67 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 SLP-HRC-SS SLP-HRC-ZC-SS HORIZONT AL TERMINA TION CAP B. V ent Components Diagrams (continued) Figure 16.4 SLP Series V ent Components SLP90 SL-2DVP DVP-FBHT DVP-FBHT 7 in. (178 mm) 15-1/2 in.
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 68 D. Service Parts Beginning Manufacturing Date: March 201 1 Ending Manufacturing Date: ______ SOHO-N-AUB 1 2 3 Log Set Assembly IMPORT ANT ; THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
69 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 SOHO-N-AUB IMPORT ANT ; THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 70 Service Parts SOHO-N-AUB IMPORT ANT ; THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
71 Heat & Glo • SOHO-N-AUB • 2197-980 Rev . F • 5/12 E. Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
デバイスHeat & Glo LifeStyle 2197-980の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Heat & Glo LifeStyle 2197-980をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHeat & Glo LifeStyle 2197-980の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Heat & Glo LifeStyle 2197-980の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Heat & Glo LifeStyle 2197-980で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Heat & Glo LifeStyle 2197-980を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHeat & Glo LifeStyle 2197-980の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Heat & Glo LifeStyle 2197-980に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHeat & Glo LifeStyle 2197-980デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。