Heat & Glo LifeStyleメーカー6000TV-OAKの使用説明書/サービス説明書
ページ先へ移動 of 20
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 1 Model: 6000TV -OAK 6000TV -OAK-IPI Underwriters Laboratories Listed In the Commonwealth of Massachusetts: • installation must be performed by a licensed plumber or gas fitter; • a CO detector shall be installed in the room where the appliance is installed.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide . NO OTHER vent systems or component s MA Y BE USED .
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 3 TABLE OF CONTENTS Safety and W arning Information . ............................................... 2 Service Parts Lists . ..............................................
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 4 Part number list on following page. 6 Log Set Assembly 5 4 2 1 3 11 10 12 8 7 9 13 (NG , LP) Exploded Parts Diagram Ser.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 5 Service Parts List ITE M CO M MO N P A RTS SERI A L # PAR T N U MB E R 1B u r n e r N G , L P SRV383-338A 2 G lass Door.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 6 (NG , LP) Exploded Parts Diagram Service Parts Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: ______ Intermittent Pilot Ignition V alve Assembly IT E M DES CRI PT I O N SERI A L # PAR T N O.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 7 (NG , LP) Exploded Parts Diagram Service Parts 6000TV -OAK Beginning Manufacturing Date: 4-01 Ending Manufacturing Date.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 8 Appliance Certification The Heat & Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 9 2 Getting St arted Introducing the Heat & Glo Gas Fireplaces Heat & Glo B-type vent gas fireplaces are designed to op- erate with all exhaust gases expelled to the outside of the building.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 10 Figure 1. Diagram of the 6000TV -OAK GA S ACCESS GAS CONT ROL S RA TING P LA T ES & LABELS VE N T COLLAR S HOOD ST.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 11 3 Inst alling the Fireplace Step 1. Locating the Fireplace The diagram shows space and clearance requirements for locating a fireplace within a room.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 12 Step 3. Negative Pressure Make-up Air Negative Pressure warning : When negative pressure is present, an atmospherically vented fireplace (with a draft hood) may not function properly and it may down draft.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 13 ! ! Step 4. Inst alling the V ent System A. V ent System Approvals Model 6000TV -Oak is approved to use 6-inch (152mm) diameter B-type vent. B-type vent must be used when the vent system is within combustible construction.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 14 ! C. Bedroom Installation in Canada This model MUST NOT be vented into a vent system in- stalled exterior to a building. The part of the vent system above the roof line can be exterior to the building.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 15 Figure 9. Gas Supply Line • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 16 Step 9. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS TO PREVENT ACCIDENT AL FIREPLACE OPERA TION.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 17 For Intermittent Pilot Ignition (IPI) Wiring 3 V olt T ransformer This appliance comes with a 3 volt transformer . The trans- former plugs into the junction box and the two leads plug into the green control module (see Figure 12).
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 18 Step 10. Finishing Figure 13 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 19 Glass Specifications: TEMPERED Figure 16. Placement of the Ember Material Figure 15. Glass Assembly Step 12. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork from underneath the fireplace.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 20 4 Maint aining and Servicing Y our Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing .
デバイスHeat & Glo LifeStyle 6000TV-OAKの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Heat & Glo LifeStyle 6000TV-OAKをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHeat & Glo LifeStyle 6000TV-OAKの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Heat & Glo LifeStyle 6000TV-OAKの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Heat & Glo LifeStyle 6000TV-OAKで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Heat & Glo LifeStyle 6000TV-OAKを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHeat & Glo LifeStyle 6000TV-OAKの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Heat & Glo LifeStyle 6000TV-OAKに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHeat & Glo LifeStyle 6000TV-OAKデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。