Heat & Glo LifeStyleメーカーCosmo-130の使用説明書/サービス説明書
ページ先へ移動 of 35
1 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 Models: Cosmo-I30 Cosmo-I35 • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________.
3 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 4 B. Limited Lifetime W arranty.
5 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 B. Limited Lifetime W arranty (continued).
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 6 C. BTU Specifi cations MODELS: Cosmo-I30, Cosmo-I35 LABORA TORY : Underwriters Laboratories, Inc.
7 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 2 Operating Inst ruc tions Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury .
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 8 C. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth.
9 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 I. Before Lighting Fireplace Before operating this fi replace for the fi rst time, have a qualifi ed technician : • V erify all shipping materials have been removed from inside and/or underneath the fi rebox.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 10 J. Lighting Instructions (IPI) The IPI system may be operated with four AA-cell batteries. When using batteries, unplug the transformer . T o prolong bat- tery life, remove them when using the transformer .
11 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 Initial Break-in Procedure • The appliance should be run three to four hours continuously on high. • T urn the appliance off and allow it to completely cool. • Remove fi xed glass assembly .
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 12 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care.
13 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 14 Burner Ignition and Operation Frequency: Annually By: Service T echnician T ools needed: Protective gloves, vacuum cleaner , whisk broom, fl ashlight, voltmeter , indexed drill bit set, and a manometer .
15 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual VERTICAL TERMINA TION CAP (SECTION 8.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 16 B. Design and Installation Considerations Heat & Glo gas inserts are designed for installations into solid fuel masonry or factory built fi replaces that have been installed in accordance with the National, Provin- cial, State and local building codes.
17 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 5 F ireplace Si ze Requirements Figure 5.1 Fireplace Opening In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 18 B. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing or fi nishing material closer than the minimums listed must be construct- ed entirely of noncombustible materials (i.
19 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 ..................
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 20 7 Installation Preparation Prepare the existing solid fuel masonry or factory built non-combustible fi rebox for installation.
21 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 B. V enting Components CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during instal- lation.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 22 Figure 8.2 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE • T rim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 8.2). • Place 3/8 inch bead of 300º F silicone on fl ue tile top.
23 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 F . Installing Adaptor and T ermination Cap For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 8.4) . T o install adaptor see Figure 8.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 24 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a quali fi ed technician (NFI certifi ed or factory-trained) using Hearth & Home T echnologies specifi ed and approved parts.
25 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 26 Figure 10.2 Fan Wiring Diagram BLOWERS BLOWER RECEPT ACLE BLK GRN BLK BLK GRN BLK WHT GRN BLK BLK GRN WHT BLK BLK BLK BLK PLUG.
27 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 PLUG 120V EXISTING OUTLET GRN (2) BLK (2) BLK (2) GRN (2) BLK (2) STEPS 3 & 4 WHT (2) BLOWER SPEED CONTROL (RHEOST A T) SE.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 28 11 F inishing A. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing or fi nishing material closer than the minimums listed must be construct- ed entirely of noncombustible materials (i.
29 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 A. Remove Glass Assembly See Section 12.F . B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cavity .
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 30 G. Air Shutter Setting Air shutter settings should be adjusted by a qualifi ed ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run.
31 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 13 T roubles hooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 32 IntelliFire Plus™ Ignition System (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but con- tinues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame rectifi cation has not occurred.
33 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 14 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 34 B. V ent Kits Components Direct V ent Flex Liner Kits (see Figure 14.2) LINK-DV -30B or (LINK-DV -30): Masonry 3 inch fl ex liner kit. Expands to 30 feet. Includes: two liners, termination cap, fl ashing, and link adapter .
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 40 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
デバイスHeat & Glo LifeStyle Cosmo-130の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Heat & Glo LifeStyle Cosmo-130をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHeat & Glo LifeStyle Cosmo-130の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Heat & Glo LifeStyle Cosmo-130の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Heat & Glo LifeStyle Cosmo-130で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Heat & Glo LifeStyle Cosmo-130を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHeat & Glo LifeStyle Cosmo-130の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Heat & Glo LifeStyle Cosmo-130に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHeat & Glo LifeStyle Cosmo-130デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。