Heat & Glo LifeStyleメーカーEM-415 - 36の使用説明書/サービス説明書
ページ先へ移動 of 53
1 Owner ’ s Manual Installation and Operation Models: EM-415 - 36” EM-485T - 42” Circulating Wood Burning Fireplace DO NOT DISCARD THIS MANUAL NOTICE • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation.
2 Read this manual before installing or operating this replace. Please retain this owner ’ s manual for future reference. Homeowner Reference Information Model Name: Date purchased/installed: Ser.
3 Note: An arrow ( ) found in the text signies change in content. Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
4 W arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer .
5 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor . A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation.
6 1 Listing and C ode A ppro vals NOTICE: This fireplace is tested and approved as a decorative replace. It should not be factored as a primary heat source in residential heating calculations.
7 2 Operat ing Instruc tions W ARNING! DO NOT operate replace before reading and understanding operating instructions. Failure to operate replace according to operating instructions could cause re or injury . User Guide W ARNING Hot glass will cause burns.
8 • The rst three or four res should be of moderate size to allow the oils and binders to be burned from the repla ce and the refractory and paint to cure. Y ou may notice an industrial odor the rst few res. This is considered normal.
9 FULL Y OPEN CORRECT P ARTL Y CLOSED INCORRECT P ARTL Y OPEN INCORRECT FULL Y CLOSED CORRECT Figure 2.2 Operating Positions of Bi-fold Doors W ARNING! Risk of Fire and Smoke! Fireplaces equipped with doors should be operated only with doors fully open or doors fully closed.
10 N. Wood Fuel Hardwood vs Softwood Y our replace performance depends on the quality of the rewood you use. • Seasoned wood contains about 8,000 BTUs per pound . • Hard woods are more dense than soft woods. • Hard woods contain 60% more BTUs than soft woods.
1 1 3 Maintenance and Ser vice Figure 3.1 Chimney & T ermination Cap Cleaning A. Disposal of Ashes Frequency: When they reach bottom of grate By: Homeowner W ARNING! Risk of Fire! Ashes could contain hot em- bers. • Place ashes in a metal container with a tight-tting lid.
12 C. Check Firebox Refractory Frequency: After each ash removal By: Homeowner D. Inspect Grate Frequency: After each ash removal By: Homeowner Inspect grate for: • W arping or sagging 1-1/2 in.
13 4 T roubles hooting Guide Start Fire Problems Possible Cause Solution Can’t get re started Excessive smoke or spillage Burns too slowly Smolders, sizzles Not enough kindling/paper or no kindling/paper Use dry kindling, more paper . Arrange kindling & wood for air movement.
14 5 Get ting Star ted A. T ypical Fireplace System Installer Guide ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Non-combus.
15 Negative pressure results from the imbalance of air avail- able for the replace to operate properly . It can be stron- gest in lower levels of the house.
16 Marginal Location: • Below peak Location NOT recommended: • Not the highest point of the roof • Wind loading possible Multi-level Roofs Windward Leeward Recommended Location: • Above peak R.
17 Before beginning the installation be sure the following tools and building supplies are available: Reciprocating saw Framing material Pliers High temp caulking material Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric drill and bits Plumb line Safety glasses Level T ape measure 1/2-3/4 in.
18 6 F raming & Clearances F E D B C Across a corner G As a room divider A 48 in. (1219 mm) minimum B Along a wall B A 5/8 in. (16 mm) all configurations G 3/4 in. (19 mm) min. air space from fireplace to combustible materials. 1/2 in. (13 mm) allowed at nailing flanges.
19 B. Clearances W ARNING! Risk of Fire! Y ou must comply with all minimum air space clearances to combustibles as specied in Fig- ure 6.2. DO NOT pack required air spaces with insulation or other materials. Heat & Glo • EM-415, EM-485 • 33056 • Rev AF 7/12 • (insulation) 0 in.
20 B A 12 in. [305 mm] 9 3/4 in. [248 mm] 12 in. [305 mm] 10 3/4 in. [273 mm] FLUSH FRONT 4 in. [102 mm] BRICK FRONT 50° angle 39° angle Grid represents 1 in. scale A Fireplace Opening B Outside Dimensions in. 36 42 mm 914 1067 in. 42 48 mm 1067 1219 EM-415 EM-485 Model # D.
21 7 Installation of Fi replace CAUTION! Risk of Cuts/Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp. A. Things to Consider • Location of chimney air kit (see Figure 7.4) • Location(s) of outside air kit • Electrical connections and/or wall switch • Gas line piping B.
22 Outlet placed higher than 3 ft below the termination cap Attic space Garage or combustible liquids storage Outlet blocked by snow , leaves, etc. Clear area outside house or in ventilated crawl spac.
23 • Hearth & Home T echnologies Inc recommends using UL181 Class 0 or Class I rigid or flexible ducting. • Secure flex duct with metal tape, screws or wire ties. Outside Air Hood 2 Wire T ies Flexible Duct (not supplied) Inlet Ring Figure 7.5 Outside Air Installation E.
24 G. Installation of Fan Follow installation instructions supplied with fan kit. Figure 7.9 Attach the Heat Shield Figure 7.10 Attach the Junction Box Bend this tab down 90 degrees Bend this half tab down 90 degrees Slide the flanges of the junction box through the slots in the bracket.
25 Chimney must extend beyond combustible roof structure Maintain minimum height of chimney above roof Additional support for tall chimneys Install roof flashing according to minimum requirements Main.
26 A. Chimney Requirements Measure vertical distances from the base of the replace as shown in Figure 8.2. 20 ft (6.10 m) max. pipe between an offset & return Ceiling firestop 35 ft (10.7 m) max. straight unsupported chimney height 16.5 ft (5.03 m) min.
27 T able 8.2 B. Using Offsets/Returns • Use an offset/return to bypass overhead obstructions. • An offset and return can be used as a single entity or separated by chimney section(s). A B 1-1/4 in. (32 mm) OVERLAP Figure 8.3 Chimney Offset/Return W ARNING! Risk of Fire! DO NOT use offset/returns greater than 30°.
28 Figure 8.4 Assembling Chimney Sections ROOM ABOVE (non-insulated ceiling) A TTIC ABOVE (insulated ceiling) B A Ceilng firestop from bottom Ceiling firestop from top Note: Use same dimensional lumber for framing ceiling firestop and joists. Figure 8.
29 3 in. (76 mm) overlap Insert three screws Bend inward 90° Bend remaining tabs to rest against pipe to prevent insula tion from falling in. Figure 8.6 Prepare Attic Insulation Shield Installation of a ceiling restop is required • Refer to Figures 8.
30 Figure 8.9 Ceiling/Attic Construction H. Complete Installation W ARNING! Risk of Fire! Y ou MUST maintain 2 in. (51 mm) air space to insulation and other combustible materials around the chimney system. Failure to do so could cause overheating and re.
31 Slanted Roofs Flat Roofs Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.6 m) above any portion of the roof or adjacent structures within 10 ft (3 m) of the chimney Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.
32 9 Chas e Inst allations Firestop Spacer Metal Chase T op Round T ermination Cap False Ceiling Insulation in the outside walls of the chase Attic Insulation Shield Chimney Firestop Spacer T abs False Ceiling False Ceiling Insulation Insulation Figure 9.
33 Slope Downward (1/4 in. per foot minimum) T urn-down Drip Edge Chase 2 in. (51 mm) Collar on Chase T op .018 (26 ga) min. Galvanized Chase T op Figure 9.3 Chase T op Construction B. Install Fireplace & Chimney Install as per Sections 7 and 8. Heat & Glo • EM-415, EM-485 • 33056 • Rev AF 7/12 • C.
34 D. Install T ermination Cap Install the chimney sections up through the chase enclo- sure. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line to prevent leaks • Refer to termination cap instructions.
35 Heat & Glo • EM-415, EM-485 • 33056 • Rev AF 7/12 • Chimney Pipe Chase T op T ermination Cap Chase Collar 2 in. (51 mm) Minimum Height T ermination cap pipe and chimney section must overlap 1-1/2 in. (38 mm). Place waterproof sealer under each flange of the termination cap and on top of each screw to help prevent leaks.
36 3 in. (76 mm) tall legs Ø 17 1/2 in. (444.5 mm) Round Hole to fit over cap Length x Width to fit inside shroud Figure 10.1 Radiation Shield 1 0 Shrouds • Chase top shrouds may be eld constructed where permitted by regional building codes. W ARNING! Risk of Fire! Shrouds must be constructed as specied.
37 3 in. (76 mm) Min. Opening Height Min. Base Dim Min. Height above radiation shield Min. Base Dim 3 in. (76 mm) Min. Radiation Shield Height from top of Chase Min. Opening Width Figure 10.3 Mailbox Style Shroud Dimensions Minimum Opening Height Minimum Base Dimension Min.
38 C B A C A B C in. 52 16 8 mm 1321 406 203 in. 66 20 12 mm 1676 508 305 Hearth Extension Dimensi ons EM-415 (HX3) EM-485 (HX4) Model # 1 1 Finis hing A.
39 D. Finishing Material Refer to Section 1 1 for combustible/non-combustible ma- terials. Refer to Figure 1 1.9 for non-combustible zone. W ARNING! Risk of Fire! Y ou must maintain clearances. • Use only non-combustible framing material below standoffs.
40 E. Combustible Mantel • Re f er t o t h e s ha d ed ar e as of Fi g ur e 1 1.1 1 for locations and dimensions of a combustible mantel. • A comb ustibl e mantel may be posit ioned no lower than 12 in. (305 mm) above the top of the replace opening.
41 Firebox Repack Insulation Knockout Combustible Materials Maintain air clearance to combustibles. Gas line Combustible materials may be located at zero clearance to gas line beyond 4 in. (102 mm) from fireplace side. Gas line 1-1/2 in. (38 mm) air space Refractory Seal with fireplace mortar or high temp non-combustible sealant 4 in.
42 1 3 Reference Materials A. Fireplace Dimensions Model # A B C D in. 36 42 28 1/4 14 1/8 mm 914 1067 718 359 in. 42 48 30 7/8 15 1/2 mm 1067 121 9 784 394 EM-415 EM-485 4-1/4 in. (108 mm) 9-5/8 in. (244 mm) 8-5/8 in. (219 mm) 13-1/2 in. (343 mm) Gas Knockout Outside Air 9-1/4 in.
43 Catalog # Description EM-415 Circulating Fireplace with Integral Grate, Hearth Protection Strips, T raditional Brick Pattern Refractory and junction box EM-415H CirculatingFireplace with Integral G.
44 B. Fireplace Components ( continued ) GR23 & GR24Integral Grate Bi-fold Glass Doors DM1736 DM1742 Herringbone Pattern Refractory 16 in. (406 mm) 52 in.
45 C. Chimney Components The following pictures show only those chimney compo- nents which may be safely used with this replace. ID4 Insulated Duct UD4 Uninsulated Duct 42 in.
46 C. Chimney Components Heat & Glo • EM-415, EM-485 • 33056 • Rev AF• 7/12 SL315/SL330 Offset/Return A B 14-1/2 in. (368 mm) Ceiling Firestop Assembled Diameter: 14 1/2 in./368 mm Height: 24 in./610 mm AS8 Straight Attic Insulation Shield JB877 Chimney Joint Band 10-1/2 in.
47 C. Chimney Components Heat & Glo • EM-415, EM-485 • 33056 • Rev AF 7/12 • TR342 Round T elescoping T ermination Cap 34-3/4 in. (883 mm) 32-1/2 in. (826 mm) ST375 Square T ermination Cap 23 in. (584 mm) 19 in. (483 mm) 15-5/8 in. (397 mm) TS345/TS345P Square T ermination Cap 13 1/4 in.
48 A B C D LDS33/LDS46 Decorative Shroud E D A C B LDS-BV Decorative Shroud Catalog # A B C D in. mm in. mm in. mm in. mm LDS33 36 914 36 914 8.5 216 1 1 279 LDS46 48 1219 72 1829 8.5 216 1 1 279 Catalog # A B C E E LDS-BV in. 26 12.5 15.5 22 23 mm 660 318 394 533 584 C.
49 1 2 3 4 5 6 10 9 8 7 Service Parts Diagram 36 in. Energy Master Circulating Fireplace EM-415 Beginning Manufacturing Date: Aug 1999 Ending Manufacturing Date: Active Service Parts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
50 Beginning Manufacturing Date: Aug 1999 Ending Manufacturing Date: Active EM-415 Service Parts Heat & Glo • EM-415, EM-485 • 33056 • Rev AF• 7/12 13 1 1 12 12 T raditional Refractory IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
51 EM-485T Beginning Manufacturing Date: Sept 2000 Ending Manufacturing Date: Active 42 in. Master Circulating Fireplace Service Parts 1 2 3 4 5 6 10 9 8 7 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
52 EM-485T Beginning Manufacturing Date: Sept 2000 Ending Manufacturing Date: Active T raditional Refractory Service Parts 13 1 1 12 12 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
53 – NOTES – E. Contact Information DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation.
デバイスHeat & Glo LifeStyle EM-415 - 36の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Heat & Glo LifeStyle EM-415 - 36をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHeat & Glo LifeStyle EM-415 - 36の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Heat & Glo LifeStyle EM-415 - 36の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Heat & Glo LifeStyle EM-415 - 36で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Heat & Glo LifeStyle EM-415 - 36を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHeat & Glo LifeStyle EM-415 - 36の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Heat & Glo LifeStyle EM-415 - 36に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHeat & Glo LifeStyle EM-415 - 36デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。