Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 1 Model(s): FB-GRAND-S FB-IN-S • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - Do not try to light any appliance - Do not touch any electrical switch.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installe.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 3 T able of Contents 1 Listing and Code Approvals A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. BTU Speci fi cations . . . . . . . . . . .
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 4 Note : T o assure top performance, safety and ef fi ciency , inserts must be installed with an approved fl ue liner as per CAN/CGA B-149 or National Fuel Gas Code ANSI Z223 and these instructions.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 5 Heat & Glo gas inserts are designed for recessed installa- tions into solid fuel masonry or factory built non-combustible fi replaces that have been installed in accordance with the National, Provincial, State and local building codes.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 6 3 3 F ireplace Size Requirements A. Minimum Fireplace Opening Minimum fi replace opening requirements are shown in Figure 3.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 7 B. Clearances Figure 3.2 Clearances to Mantels or other Combustibles above Appliance Fire Risk. • Locate and install appliance to all clearance speci fi cations in manual. Fire Risk.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 8 Fire Risk. Asphyxiation Risk. • T erminations MUST meet minimum clearances. • Exhaust gases are hot. • Nearby vents may draw fumes into house. A. V ent T ermination Minimum Clearances Figure 4.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 9 CAUTION ALL vent speci fi cations MUST be followed. • This product is tested and listed to these speci fi cations. • Appliance performance will suffer if speci fi cations are not followed.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 10 6 6 Installation Preparation Fire Risk. A hearth or hearth extension (if present) must comply with either of the following: • The solid fuel burning fi replace manufacturer’s speci fi cation.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 11 A. V enting Components 7 7 Installing V ent P ipe and Appliance The vertical vent termination system installed on this model includes: • One 3-foot section stainless steel fl exible pipe (included with insert).
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 12 Figure 7.2 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE • T rim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 7.2). • Place 3/8 inch bead of 300º F silicone on fl ue tile top.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 13 D. Installing Adaptor and T ermination Cap For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 7.2) . T o install adaptor see Figure 7.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 14 • Ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes. • Incoming gas line should be piped into the valve compartment and connected to the 1/2 inch connection on the manual shutoff valve.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 15 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory . • Changing valve settings may result in fi re hazard or bodily injury . HIGH AL TITUDE INST ALLA TIONS U.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 16 A. Wiring the Appliance 9 9 Elect rical Infor mation Note : This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code, CSA C221.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 17 B. Junction Box Installation Figure 9.2 Junction box installation JUNCTION BOX SIDEW ALL FEED PLUG THROUGH HOLE INSERT STRAIN REL.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 18 Figure 9.4 Fan Wiring Diagram NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105 0 C RA TED WIRE.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 19 A. Mantel Projections Figure 10.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance, not the surround.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 20 Figure 1 1.1 Placement of Embers EMBER MA TERIAL (TOP SURF ACE, AND FRONT) BURNER P AN AIR SHUTTER 1 1 11 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 21 Log Set Assembly: LOGS-CFXGB E. Positioning the Logs This model uses locating tabs to positively locate the logs with respect to the grate assembly . Please refer to grate assembly .
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 22 LOG NUMBER 3 (SR V768-705): Position log #3 onto grate such that tab E fi ts into slot on bottom surface of log.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 23 LOG PLACEMENT INSTRUCTIONS Carefully remove the logs from the packaging. CAUTION: Logs are fragile! 773-936B 10/07 GRA TE ASSEMBL Y This model uses locating tabs to positively locate the logs with respect to the grate assembly .
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 24 LOG #2 (SRV773-702): Position Log #2 onto grate such that tab C fi ts into the slot on bottom surface of log.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 25 Figure 1 1.16 Glass Assembly F . Glass Assembly Removing Glass Assembly There are two glass latches on the bottom of glass assembly . • T o release glass assembly , pull latch forward and allow to retract away from glass assembly .
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 26 Fire Risk. Explosion Risk. Gas may build up while lighting pilot. • Remove glass assembly before lighting pilot. • Replace glass assembly after lighting pilot. A. Before Lighting Appliance This appliance has a Standing Pilot Ignition.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 27 B. Lighting Appliance Standing Pilot Ignition 1. T urn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 28 C. Check Pilot Flame Appearance Pilot fl ame must contact the thermocouple and thermopile for reliable appliance operation. • Pilot fl ame should be as shown in Figure 12.1. D.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 29 E. Frequently Asked Questions Fire Risk. High T emperatures. Keep combustible household items away from appliance. Do NOT obstruct combustion and ventilation air . • Do NOT place combustible items on top of or in front of appliance.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 30 A. Standing Pilot Ignition System 1 3 13 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 31 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. Continued c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 32 1 4 14 Maintaining and Ser vicing Appliance Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance checkup at the beginning of each heating season.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 33 Inspect Maintenance T asks Doors, Surrounds and Fronts 1. Assess condition of screen and replace as necessary . Recommend addition of screen if one is not present. 2. Inspect for scratches, dents or other damage and repair as necessary .
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 34 Figure 15.1 Appliance Dimensions D F E H G ELECTRICAL ACCESS (IF EQUIPPED) GAS INLET C A B 2-1/16 in. 52 mm 1-9/16 in. 40 mm 3-9/16 in. 91 mm 1-1/16 in. 28 mm 2-1/2 in. 64 mm 4 in.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 35 B. V ent Kits Components Direct V ent Flex Liner Kits (see Figure 15.2) LINK-DV -30B or (LINK-DV -30): Masonry 3 inch fl ex liner kit. Expands to 30 feet. Includes: two liners, termination cap, fl ashing, and link adapter .
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 36 C. Service Parts Service Parts Diagram FB-GRAND-S Beginning Manufacturing Date: Oct.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 37 Service Parts List FB-GRAND-S IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 38 Service Parts Service Parts Diagram FB-IN-S Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date: ______ Part number list on following page.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 39 Service Parts List FB-IN-S IMPORT ANT THIS IS DA TED INFORMA TION: When Requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 40 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 41 © 2007 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY HEA T & GLO GAS APPLIANCE PRODUCTS 060-981E 10/07 D. Limited Lifetime W arranty BASIC ONE-YEAR W ARRANTY .
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev . D • 3/08 42 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .heatnglo.com E. Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
デバイスHeat & Glo LifeStyle FB-GRAND-Sの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Heat & Glo LifeStyle FB-GRAND-Sをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHeat & Glo LifeStyle FB-GRAND-Sの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Heat & Glo LifeStyle FB-GRAND-Sの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Heat & Glo LifeStyle FB-GRAND-Sで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Heat & Glo LifeStyle FB-GRAND-Sを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHeat & Glo LifeStyle FB-GRAND-Sの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Heat & Glo LifeStyle FB-GRAND-Sに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHeat & Glo LifeStyle FB-GRAND-Sデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。