GLDH Parts List 15-February-2012 This parts list is current as of the above revision date. Form Number:92-42810-GLDH Form No. 92-42810-GLDH.
Page 2 of 16 T ab le of Contents 15-February-2012 92-42810-GLDH O r i f i c e S e l e c t i o n C h a r t ................................................. P a g e 1 1 E x p l o d e d V i e w ......................................................... P a g e 1 2 H e a t E x c h a n g e r - B u r n e r G r o u p .
Page 3 of 16 15-February-2012 92-42810-GLDH MODEL NUMBER EXPLANA TION G L D H - 6 0 E 3 B 1 2 3 4 5 6 7 (1) GAS (2) 90% EFFICIENCY (3) DO WNFLO W/HORIZONT AL CONDENSING (4) PLA CEHOLDER (5) HEA TING I.
Page 4 of 16 15-February-2012 92-42810-GLDH No. Notes MODEL HEA TING CAP A CITY V ARIA TIONS GLDH 45E 3B GLDH 60E 3B GLDH 75E 3B GLDH 75E 4B P ANELS, SHEET MET AL, MISCELLANEOUS 1 Blower/Filter Door A.
Page 5 of 16 15-February-2012 92-42810-GLDH No. Notes MODEL HEA TING CAP A CITY V ARIA TIONS GLDH 90E 4B GLDH 90E 5B GLDH 105E 5B GLDH 120E 5B P ANELS, SHEET MET AL, MISCELLANEOUS 1 Blower/Filter Door.
Page 6 of 16 15-February-2012 92-42810-GLDH No. Notes MODEL HEA TING CAP A CITY BLO WER DESIGNA TION GLDH ALL ALL P ARTS B AG Complete Parts Bag Assembly AS-100717-03 1/2 in. PVC Pipe - 4 in. 68-22024-04 1/2 in. T ee 68-21980-02 PVC V ane 68-23473-01 PVC Wind V ane - 2 1/2 in.
Page 7 of 16 15-February-2012 92-42810-GLDH No. Notes MODEL HEA TING CAP A CITY V ARIA TIONS GLDH 45E 3B GLDH 60E 3B GLDH 75E 3B GLDH 75E 4B ELECTRICAL GROUP 3 Induced Draft Blow er w/Gasket 70-24033-.
Page 8 of 16 15-February-2012 92-42810-GLDH No. Notes MODEL HEA TING CAP A CITY V ARIA TIONS GLDH 45E 3B GLDH 60E 3B GLDH 75E 3B GLDH 75E 4B BLO WER GROUP 44 Stk Blower Assemb ly (Includes items 45-48.
Page 9 of 16 15-February-2012 92-42810-GLDH No. Notes MODEL HEA TING CAP A CITY V ARIA TIONS GLDH 45E 3B GLDH 60E 3B GLDH 75E 3B GLDH 75E 4B HEA T EXCHANGER, BURNER / MANIFOLD GROUP 17 Stk Limit - Man.
Page 10 of 16 15-February-2012 92-42810-GLDH No. Notes MODEL GAS CODE GLDH GY GLDH EJ GLDH EL GAS CONTROLS 51 Stk Integrated Furnace Control Board (IFC) 62-25338-01 62-24140-04 62-24140-04 61 Stk Gas .
Page 1 1 of 16 15-February-2012 92-42810-GLDH 90% GAS FURNA CE - ORIFICE SELECTION CHART - NA TURAL GAS CA UTION: Selection of the correct Natural Gas Orifice requires the following inf ormation for the specific installation: 1) Altitude in of the installation (ft.
Page 12 of 16 15-February-2012 92-42810-GLDH Exploded View.
Page 13 of 16 15-February-2012 92-42810-GLDH Horizontal Installation Parts.
Page 14 of 16 15-February-2012 92-42810-GLDH Blower Assembly.
Page 15 of 16 15-February-2012 92-42810-GLDH Burner Assembly.
NO TES 1900 Wellworth Jackson, MI 49203 Stk It is recommended that stock be maintained for this par t. N/A Not Applicable 1 Order Gas V alve f or Natural Gas along with LP Conv ersion Kit 2 Units manuf actured before F5109 used a limit s witch with a set point diff erent that the specified replacement.
デバイスHeat Controller 92-42810-GLDHの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Heat Controller 92-42810-GLDHをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHeat Controller 92-42810-GLDHの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Heat Controller 92-42810-GLDHの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Heat Controller 92-42810-GLDHで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Heat Controller 92-42810-GLDHを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHeat Controller 92-42810-GLDHの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Heat Controller 92-42810-GLDHに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHeat Controller 92-42810-GLDHデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。