Model 590/592 This section provides checkout and replacement procedures, for various parts of the fryer . Before replacing any parts, refer to the T roubleshooting Section to aid you in fi nding the cause of the malfunction. 1. A multimeter will help you to check electric components.
Model 590/592 This high temperature control is a safety , manual reset control, which senses the temperature of the shortening. If the shorten- ing temperature exceeds 425°F (218°C), this switch opens and shuts off the heat to the frypot.
Model 590/592 T o avoid electrical shock of property damage, move the power switch to OFF and disconnect main circuit breaker , or unplug cord at wall receptacle. Replacement 1. If the tube is broken or cracked, the control will open, shutting off electrical power .
Model 590/592 1 1. Pull excess capillary line from pot and tighten nut into frypot wall. Be sur e capillary bulb of high limit is positioned so it does not interfer e with carrier or get damaged when cleaning frypot. 12. W ith excess capillary line pulled out, tighten smaller nut.
Model 590/592 The POWER/PUMP switch is a three way rocker switch with a center OFF position. W ith switch in the POWER position, the fryer operates. W ith switch in PUMP position, the fi lter pump operates, but the unit will not heat.
Model 590/592 The temperature probe relays actual shortening temperature to the control. If it becomes disabled, “E06” will show in the dis- play . Also, if temperature is out of calibration more than 10°F , or 10°C, the temperature probe should be replaced.
Model 590/592 Should the control panel become inoperative, follow these instructions for replacing the board. 1. Remove electrical power supplied to the fryer . T o avoid electrical shock or pr operty damage, move the power switch to OFF and disconnect main circuit breaker , or unplug cord at wall r eceptacle.
Model 590/592 The Lid Assembly is easily tilted up for cleaning or servicing. 1. Raise the lid and remove racks and carrier . 2. Grasping the lid handle, lift the front of the lid up until it stops in an upright position.
Model 590/592 The Lid Counterweight in the back of the fryer balances the weight of the lid system to allow easier opening and closing of the lid. The weight has two cables attached to it, and weighs about 150 lbs. (67.5 Kg). 1. Using a 3/8” socket, remove the nuts securing rear shroud of the fryer and remove the shroud.
Model 590/592 The pressure pads are plastic strips that the lid cam presses against to seal the lid. 1. Raise the lid. 2. Remove the 4 screws securing the lid cover and remove cover . 3. Push the lid cam back, off of the pressure pads. 4. Using an Allen wrench, remove the large bolt securing the pad.
Model 590/592 If steam leaks out from around the lid gasket, the pressure pads could be worn or broken. If the pressure pad is worn, but not broken, it can be reversed 180 degrees, and the other end of the pad used.
Model 590/592 This is an electro-mechanical device that causes pressure to be held in the frypot. The solenoid valve closes at the beginning of the Cook Cycle and opens automatically at the end of the Cook Cycle. If this valve should become dirty , or the T e fl on seat nicked, pressure will not build up.
Model 590/592 5. If the core-disc assembly is sticking due to buildup of shortening, breading, and food particles, proceed with the following steps: a. Unscrew the solenoid bonnet assembly from solenoid valve body . b. Remove solenoid bonnet assembly and bonnet gasket.
Model 590/592 13. W et “O” ring around seat with water and insert O-ring assembly ( fl at side fi rst) in valve through “IN” side of body . Use an eraser end of pencil and press in the T e fl on seal until it snaps into place. Be careful not to mar or nick the seat.
Model 590/592 DO NOT PULL THE RING ON THE SAFETY RELIEF V AL VE. HOT STEAM WILL BE RELEASED AND SEVERE BURNS WILL RESUL T . 1. At the end of each day’ s usage of the fryer , the deadweight valve must be cleaned. The fryer must be OFF and pressure released.
Model 590/592 2. Use a wrench to loosen the valve from the pipe tee, turn counterclockwise to remove. 3. Clean the inside of the pipe tee with hot water . T urn the safety relief valve towards the rear of the fryer when reinstalling safety relief valve.
Model 590/592 The electric fryer requires two switching contactors: a primary and a heat contactor . The primary contactor ener gizes (contacts close) any time the POWER/PUMP switch is in the POWER position, and the temperature of the shortening is below 420 ° F ( 215° C).
Model 590/592 T o avoid electrical shock, make connections before applying power , take reading, and remove power before removing meter leads. The following checks are performed with the wall circuit br eaker closed and the main power switch in the ON position.
Model 590/592 The electric model fryer uses 2 heating elements. Heating elements are available in 208, 220/240, 380 and 415 volts. Check the data plate, on the shroud behind the lid, to determine the correct voltage elements. 1. Remove the electrical power supplied to the unit.
Model 590/592 Replacement 1. Drain the shortening. 2. Remove the high limit bulb holder from the heating element inside the frypot. 3. Disconnect the heating element wires from the contactors. Label each so it can be replaced in the same position on the new element.
Model 590/592 10. Replace the brass nuts and washers on the heating element terminals. T ighten the brass nuts to 30 foot lbs of torque. 1 1. Replace heat contactor . 12. Move the element spreaders from the center of the ele ment, into a position which will spread each element apart evenly on all four sides, and tighten.
Model 590/592 Upon pulling out on the drain handle, the microswitch should be activated and the unit will not heat, but when the handle is pushed back, the unit should operate properly . The bracket on the microswitch is slotted so it can be adjusted backward or forward.
Model 590/592 The drain valve opens when the drain valve handle is pulled out and drains the shortening out of the pot. Replacement 1. Using a 3/8” socket, remove the nuts securing the drain switch bracket, and pull the bracket from the studs. 2. Remove the nut securing the drain handle and pull the handle from the drain valve.
Model 590/592 1. Raise the lid and remove the retention ring from one end of the lid pin. 2. Slide the lid pin from unit. 3. Lift the lid from unit. The lid weighs 80 lbs (36 kg). T ake care when lifting lid to prevent personal injury . 4. Using a 3/8” socket, remove the nuts securing the rear shroud and remove shroud.
Model 590/592 1 103 2-25 2-23. NYLA TRON STRIPS REPLACEMENT (Continued 9. Lift the front shroud up and out, over the arm of the lid. 10. Thread the new nylatron strip through the track in the front shroud. 1 1. Lining up the holes in the strips, fi t the front shroud back over the lid arms.
デバイスHenny Penny 592の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Henny Penny 592をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHenny Penny 592の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Henny Penny 592の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Henny Penny 592で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Henny Penny 592を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHenny Penny 592の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Henny Penny 592に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHenny Penny 592デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。