Please read this operation Guide carefully for proper operation, and keep it for future refernce. B E-IR20 / 21 Infrared B/W Camera Module Operation Guide.
Table of Contents BE-I R20 / 21 1 1. Intr oduction ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 2 2. General ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 2 3.
1. Introducti on BE-I R20 / 21 2 Thank you v ery much for your purchase of the Hitachi BE-IR20/21 Black and W hite Camera Module. Prior to using this camera , read this manual carefully. 2 . G e n e r a l The Hitachi BE-IR20/ 21 ar e black and whit e camer a modules using a 1/ 4 inch interline CCD.
4 . . . . Specif ications BE-I R20 / 21 3 8) External sync input HD & VD : 5V peak -to-peak negative Input impedance : 1k Ω Frequency dev iat ion : ± 1% 9) Video output 1.0 Vp-p, 75 Ω , unbalanced Video component : 0.7 Vp-p Sync component : 0.
5. Notes to users BE-I R20 / 21 4 Power supply z Connect a 9V DC volt age (8. 5 t o 9. 5V) from an external regulat ed DC pow er supply . z Use a stable power supply w it hout ripple and noise.
5. Notes to users BE-I R20 / 21 5 Phenomena inherent to CCD imaging dev ice Following are phenomena inherent t o a CCD imaging dev ice , and not defect s. z Smear and blooming W hen strong light (lamp , fluorescent lamp , refl ected light , etc.) is shot , pale bands are displayed v ert ically above and below t he light.
6. External view BE-I R20 / 21 6 Dimensions 7. Optical dimensions Lens 19.2 ± 0.5 (C-mount) 1.4 ± 0.2 CCD Base plate Imaging face Lens-mount Extension of optical path due to the thicknes s of CCD glas s is considered.
8. Installation BE-I R20 / 21 7 W hen installing the camera in a housing or unit of equipment, secure with t wo M2 screws inserted into the 2. 5 mm diameters holes of the SENS board base plate. 1. Use the SENS board holds to install the camera. Avoid using only the Main board, due to risk of damage to the board connector.
9. Typical connection BE-I R20 / 21 8 BE-IR20 Image processor or Video monitor Regulated power supply (More then 300 mA) Note1 : • When more than one video monitor is connected in series , set the 75 Ω termination sw itch on the last unit to ON. Note2 : • Supply voltage range : 8.
9. Typical connection BE-I R20 / 21 9 BE-IR21 Image processor or Video monitor Regulated power supply (More then 300 mA) Note1 : • When more than one video monitor is connected in series , set the 75 Ω termination sw itch on the last unit to ON. Note2 : • Supply voltage range : 8.
10. External sync (BE-IR21) BE-I R20 / 21 10 Supply sync signals (HD and VD) f or BE-IR21 operation. Refer to connec tion on page 9. z Horizontal and vertical drive signal inputs HD EIA: f(H) = 15.734 k Hz ± 1 % VD EIA: f(V) = 59.94 Hz (f( V) = f(H) ÷ 262.
11. Function setting and changes BE-I R20 / 21 11 W hen changing the function settings , perform the work with thorough care. Be sure to use anti-static measures such as a grounding band. Also observe safety precautions when soldering to avoid burn and fire hazards.
11. Function setting and changes BE-I R20 / 21 12 11-2 Gamma response The factory setting is gamma on. If necessary , the gamma response can be changed as follows.
11. Function setting and changes BE-I R20 / 21 13 11-3 Auto electronic shutter on / off Factory sett ing for auto elect ronic shut t er is off. If necessary , it can be set t o on. Absent the R259 , R260 chip t o set t he aut o elect r onic shut t er to on.
11. Function setting and changes BE-I R20 / 21 14 11-4 Changes to fixed shutter mode The fixed shutter mode can be changed by replacing the chip parts indicat ed below .
11. Function setting and changes BE-I R20 / 21 15 11-5 BE-IR20 external sync The BE-IR20 factory sett ing is for internal sync. If required, this can be changed to external sync by changing chip part s. Change the following chip parts for external sync operat ion.
11. Function setting and changes BE-I R20 / 21 16 11-6 BE-IR21 internal sync The BE-IR21 factory sett ing is for external sync. If required, this can be changed to internal sync by changing chip part s. Change the following chip parts for internal sy nc operat ion.
11. Function setting and changes BE-I R20 / 21 17 11-7 HD and VD output (BE-IR20 only) The BE-IR20 can be provided with horizontal and vert ical drive outputs by changing chip parts.
12. Opt ions BE-I R20 / 21 18 LA-IR20 Mount adapter dimensions Remove c-mount attachment to use as cs-mount..
12. Options BE-I R20 / 21 19 BE-IR20/21 and LA-IR 20 combined dimensions.
BE-I R20 / 21 20 Spectral sensitivity (t ypical example) 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 400 500 600 700 800 900 1000 Relative sensitivity W avelength( nm).
BE-I R20 / 21 21 Caution The s pecifications of this equipm ent are subj ect to change without notice for im provem ent. Prior to placing your order , be sur e to confirm that these spec ifications are the latest ones.
デバイスHitachi 21の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hitachi 21をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHitachi 21の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hitachi 21の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hitachi 21で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hitachi 21を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHitachi 21の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hitachi 21に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHitachi 21デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。