307–586 Rev . P Supersedes M and PCN P INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE.
W ARNING INJECTION HAZARD Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause an extremely serious injury , including the need for amputation. Splashing fluid in the eyes or on the skin can also cause a serious injury .
W ARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in serious injury . D This equipment is for professional use only . D Read all instruction manuals, tags, and labels before operating the equipment.
Installation KEY A Air Line Filter B Air Line Lubricator C* Bleed–type Master Air V alve D Pump Air Regulator E* Fluid Drain V alve F Fluid Shutof f V alve G Fluid Filter.
Installation Connect the Air Line 1. Install an air line filter (A) to ensure a clean, dry air supply to the gun. Dirt and moisture in the line can ruin the appearance of your finished piece. See Fig. 1. 2. Install an air pressure regulator (L) on the gun air supply line to control the air pressure to the gun.
Installation Ground the System W ARNING FIRE AND EXPLOSION HAZARD Improper grounding could cause static sparking, which could cause a fire or explosion. T o reduce the risk of property damage or serious injury , follow the grounding instructions below .
Operation Safety W ARNING INJECTION HAZARD Remember , this is not an air spray gun. For your safety be sure to read and follow the W arnings on pages 2 and 3 and throughout the text of this instruction manual.
Operation How the Air-Assisted Airless Spray Gun Operates The air-assisted airless spray gun combines airless and air spraying concepts. The spray tip shapes the fluid into a fan pattern, as does a conventional airless spray tip.
Operation Adjust the Spray Pattern W ARNING INJECTION HAZARD T o reduce the risk of component rupture and serious injury , including injection, do not exceed the gun’ s maximum fluid working pressure of 950 psi (66 bar) or the maxi - mum working pressure of the lowest rated compo - nent in the system.
Operation Clean the Spray Gun and System Daily W ARNING INJECTION HAZARD T o reduce the risk of an injection injury or splashing fluid in the eyes or on the skin: Follow the Pressure Relief Procedure on page 7 before cleaning, removing, or installing a spray tip and whenever you are instructed to relieve pressure.
307-586 11 Operation Flush the Gun Daily W ARNING INJECTION HAZARD T o reduce the risk of a fluid injection injury , follow the Pressure Relief Proce - dure on page 7 before cleaning, removing, or installing a spray tip and whenever you are instructed to relieve pressure.
12ą307-586 T roubleshooting W ARNING INJECTION HAZARD T o reduce the risk of a fluid injection injury , follow the Pressure Relief Proce - dure on page 7 before checking or servicing any of the system equipment and when - ever you are instructed to relieve pressure.
307-586 13 Notes.
14ą307-586 Service W ARNING INJECTION HAZARD T o reduce the risk of a fluid injection injury , follow the Pressure Relief Proce - dure on page 7 before checking or servicing any of the system equipment and when - ever you are instructed to relieve pressure.
307-586 15 Service Fig. 8 25 32 28 27 30 33 24 5 47 21 49 7 11 10 52 51 50 2 A DET AIL D Fluid Needle Packings (47) See DET AIL D 33 67 1 3 2 Dif fuser-seat gasket (33) must be replaced if dif fuser-s.
Parts 25 27 28 *26 18 *21 32 30* 33* *5 *24 *47 *33 67 66 55* 3 49 50 *51 20 2 19 52* 10* 11 *63 7 33 1 For Direct Hose Connection (Parts shipped unassembled) 1 Lubricat.
307-586 17 Parts Use Only Genuine Graco Parts and Accessories Ref. No. Part No. Description Qty . 1 178–415 CONNECT OR, fluid (not assembled) 1 2 106–917 ADAPTER, air 1 3 178–454 TRIGGER, gun 1 .
Spray T ip and Air Cap Selection Charts *Light to Orifice Inches (mm) Medium *Heavy Size Fan W idth Viscosity V iscosity inches at 12” fl oz/min fl oz/min Part (mm) (300 mm) (liters/min) (liters/min) No. **0.027 8–10 (200–250) 58.
307-586 19 Spray T ip and Air Cap Selection Charts SOLID STREAM SPRA Y TIPS For use in applications requiring a solid stream of fluid such as with mastics or sealers. All these tips require Air Cap 218–336 . Orifice Size inches (mm) Part No. Pattern 0.
Accessories Use Only Genuine Graco Parts and Accessories Four Finger T rigger 183–104 Longer than standard trigger . Reduces trigger pull when spraying mastics and heavy fluids. Replaces item 3, in the parts list, page 17.
307-586 21 Dimensions 6.9 in. (175 mm) 1/4–18 npsm (R1/4–19) Compound Thread 6.7 in. (170 mm) T echnical Data Maximum W orking Fluid Pressure 950 psi (66 bar) . . . Maximum W orking Air Pressure 100 psi (7 bar) . . . . . . . Maximum W orking Fluid T emperature .
Notes.
307-586 23 Notes.
24ą307-586 The Graco W arranty and Disclaimers W ARRANTY Graco warrants all equipment manufactured by it and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.
デバイスHitachi AA 2000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hitachi AA 2000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHitachi AA 2000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hitachi AA 2000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hitachi AA 2000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hitachi AA 2000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHitachi AA 2000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hitachi AA 2000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHitachi AA 2000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。