– 2 – IMPORT ANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED.
– 3 – TABLE OF CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Standard Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– 4 – Installation, Operation and Care Of C-LINE A & A W DISHW ASHERS SA VE THESE INSTRUCTIONS GENERAL C-Line A or AW Dishwashers are fully automatic, rack-type washers that convey the rack from one end of the machine to the other, exposing the ware to progressive wash/rinse action.
– 5 – STANDARD EQUIPMENT Controls (Fig. 1) Fig. 1 The controls are mounted on top of the chamber. There are three operational control switches housed in the control box: Power (ON-OFF); Motor (ON-OFF); and Timer (MANUAL-AUTO). A pilot circuit transformer provides a reduced voltage of 115 volts for the machine controls.
– 6 – Thermometers Dial thermometers for wash and final rinse are indicated in ° F and ° C on the faceplate. Door Interlocks Door interlock switches will prevent machine operation while an inspection door is open. If a door is opened while the machine is operating, the pumps and conveyor will automatically turn off.
– 7 – OPTIONAL EQUIPMENT Blower Dryer — Dishes are dried by forced, heated air (3-phase machines only). The exhaust requirement at the vent stack of the blower dryer is 1400 CFM. Conveyor Dwell — The optional conveyor dwell switch (Conveyor ON-OFF) is housed in the control box and shuts the conveyor drive motor off.
– 8 – INST ALLA TION UNPACKING Immediately after unpacking the dishwasher, check it for possible shipping damage. If the machine is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.
– 9 – ASSEMBLY Dish tables should be fitted into the dishwasher (Fig. 2). Use mastic between table and lip of tank to prevent leakage. Rack track height should be from 1 / 4 to 5 / 16 " (Fig. 2) above the tank lip. Dish tables should be sloped so that any water carried from the dishwasher will drain back into it.
– 10 – WATER REQUIREMENTS Proper water quality can improve ware washing performance by reducing spotting, lowering chemical supply costs, enhancing effectiveness of labor and extending equipment life. Local water conditions vary from one location to another.
– 11 – FILL & FINAL RINSE CONNECTION (Fig. 5) Fig. 5 Use 3 / 4 " pipe for the connecting line. A flowing pressure of 15 to 25 psig and a minimum temperature of 180 ° F must be maintained.
– 12 – GAS CONNECTION (WHEN EQUIPPED) Check the gas data plate attached to the dishwasher or tag attached to the gas burner tubing for type of gas to be used. The burner is not adjustable. If flowing gas pressure is above 7" W.C. (natural gas) or 11" W.
– 13 – VENTING REQUIREMENTS Type II Canopy Hood Most commercial dishwashers must be provided with external venting per local codes. The exception is electric or steam heat machines operating in the chemical or low temperature sanitizing mode where the existing room ventilation will compensate for the vapors produced.
– 14 – PANT-LEG VENT CONNECTIONS (Figs. 7, 8) IMPORTANT : Gas heat machines must be provided with a means to exhaust the flue gases to the exterior of the building. Pant-Leg duct connectors (Fig. 7) alone DO NOT provide ventilation for the gas flue at the rear of the machine.
– 15 – If using the 'Pant-Leg' duct, a mini vent hood (Fig. 8), positioned about 18" above the flue exit at the rear of the dishwasher and connected to existing duct work, must be used for the flue gases. The volume of flue exhaust in the mini vent hood should not exceed 200 CFM.
– 16 – RATE OF EXHAUST FLOW CALCULATIONS Based on the 2004 International Mechanical Code (IMC). The Rate of air flow required for a vent hood is now based on the linear length of the face of the hood instead of the area of the hood opening.
– 17 – ELECTRICAL CONNECTIONS — DISHWASHER WARNING : ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 (LATEST EDITION) AND/OR OTHER LOCAL ELECTRICAL CODES. WARNING : DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES.
– 18 – ELECTRICAL CONNECTIONS — OPTIONAL EQUIPMENT WARNING : ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES. WARNING : DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES.
– 19 – CURTAIN INSTALLATION.
– 20 – OPERA TION PREPARATION Put the dishwasher strainer pans and strainer basket (Fig. 3) into position in each dishwasher tank. If the machine is equipped with an RS, CS, or PW unit, install the solid prewash strainer pan over the overflow tube, flange side down and the lip toward the rear of the tank.
– 21 – If the machine is equipped with gas heat, refer to STARTING THE GAS HEAT DISHWASHER below. The tank water temperature is regulated by the solid-state thermostat.
– 22 – DISHWASHING After the machine has filled, start pumps by pushing the Motor switch ON (Fig.1). Prescrap dishes thoroughly to remove large food particles and debris. Never use steel wool on ware that is to be loaded into the dishwasher. Stack dishes in the racks.
– 23 – CLEANING The machine must be thoroughly cleaned at the end of each working shift, or at least twice a day. Use only products formulated to be safe on stainless steel. 1. Turn the Motor and Power switches OFF . 2. Open the door(s). Standard door interlock switches prevent machine operation with inspection door(s) open.
– 24 – 13 . Thoroughly wash out the interior of the machine with a heavy-duty hose fitted with a squeeze valve. Remove remaining soil with a cloth or soft brush and mild cleanser. Rinse again with hose. Do not allow food soil to accumulate on the bottom of the tank.
– 25 – MAINTENANCE WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. Some machines may have more than one electrical power supply. All supplies MUST be disconnected. VENT When cool, check the vent of this dishwasher every six months for obstructions.
– 26 – TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE No Machine Operation. 1. Blown fuse or tripped circuit breaker at power supply. 2. Inspection door(s) not closed. 3. Conveyor jammed. 4. If Auto Timer was used, the timer may have timed out. 5. If table limit switch is used, the switch may be tripped.
– 27 – SYMPTOM POSSIBLE CAUSE Inadequate Rinse. 1. Dirty line strainer (Fig. 5) causing reduced water flow. Turn off water supply, remove strainer cap and withdraw and clean screen. Reassemble. 2. Low supply line pressure. 3. Clogged rinse nozzle(s).
NOTES – 28 – FORM 17791 Rev. O (Feb. 2006) PRINTED IN U.S.A..
デバイスHobart C44A ML-38899の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hobart C44A ML-38899をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHobart C44A ML-38899の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hobart C44A ML-38899の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hobart C44A ML-38899で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hobart C44A ML-38899を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHobart C44A ML-38899の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hobart C44A ML-38899に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHobart C44A ML-38899デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。