Cybershop 300 AC/DC Processes Description TIG (GT A W ) W elding Stick (SMA W) W elding Flux Cored (FCA W) W elding Arc Welding Power Source OM-318 126 418R December 2000 MIG (GMA W) W elding.
Hobart W elders manufactures a full line of welders and welding related equipment. For information on other quality Hobart products, contact your local Hobart distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-877-Hobart1.
The following terms are used interchangeably throughout this manual: TIG = GT AW Stick = SMAW Mig = GMAW T ABLE OF CONTENTS SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 .
.
OM-318 Page 1 SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING som _nd_5/97 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message.
OM-318 Page 2 Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly of f from the weld. ARC RA YS can burn eyes and skin. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.
OM-318 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring – be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-318 Page 4 1-5. EMF Information Considerations About W elding And The Effects Of Low Frequency Electric A n d M a g netic Fields W elding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields.
OM-318 Page 5 SECTION 1 – CONSIGNES DE SECURITE – LIRE A V ANT UTILISA TION som _nd_fre 5/97 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette proc é dure pr é sente des risques de danger ! Ceux-ci sont identifi é s par des symboles adjacents aux directives.
OM-318 Page 6 Le rayonnement de l ’ arc du proc é d é de soudage g é n è re des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provoquer des br û lures dans les yeux et sur la peau. Des é tincelles sont projet é es pendant le soudage.
OM-318 Page 7 1-3. Dangers suppl é mentaires en relation avec l ’ installation, le fonctionnement et la maintenance Risque D ’ INCENDIE OU D ’ EXPLOSION. D Ne pas placer l ’ appareil sur , au-dessus ou à proxi- mit é de surfaces infllammables.
OM-318 Page 8 1-4. Principales normes de s é curit é Safety in W elding and Cutting, norme ANSI Z49.1, de l ’ American W el- ding Society , 550 N.W . Lejeune Rd, Miami FL 33126 Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.
OM-318 Page 9 SECTION 2 – INST ALLA TION 2-1. Specifications Rated W eld Max. Input at Rated Load Output, 50/60 Hz, Single-Phase Model W eld Output Output Mode Open- Circuit Amperes At KV A KW Output Mode V oltage 200 V 220 V 230 V 380 V 415 V 460 V 575 V NEMA Class II (40): 200 Amperes, 28 V olts AC, 40% Duty Cycle AC 80 V olts AC 85 (4.
OM-318 Page 10 2-3. Duty Cycle And Overheating 5 Minutes W elding 5 Minutes Resting 4 Minutes W elding 6 Minutes Resting Duty Cycle is percentage of 10 m i n- utes that unit can weld at rated load without overheating. If unit overheats, thermostat opens, output stops, and cooling fan runs.
OM-318 Page 1 1 2-4. Selecting A Location 1 Lifting Eye 2 Lifting Forks Use lifting eye or lifting forks to move unit. If using lifting forks, extend forks beyond opposite side of unit.
OM-318 Page 12 2-6. W eld Output T erminals And Selecting Cable Sizes T otal Cable (Copper) Length In W eld Circuit Not Exceeding 100 ft (30 m) Or Less 150 ft (45 m) 200 ft (60 m) 250 ft (70 m) 300 ft.
OM-318 Page 13 2-8. 1 15 V olts AC Duplex Receptacle Ref. ST-152 973-A Y T urn Off power before con- necting to receptacle. 1 1 15 V AC Receptacle Receptacle is protected from over- load by circuit breaker CB1 (see Section 4-2). Power output is shared between this receptacle and the Remote 14 receptacle (see Section 2-7).
OM-318 Page 14 1 2-10. Placing Jumper Links And Connecting Input Power ST-130 173-K Check input voltage available at site. 1 Jumper Link Label Check label – only one is on unit. 2 Jumper Links Move jumper links to match input voltage. 3 Input And Grounding Conductors Select size and length using Section 2-9.
OM-318 Page 15 SECTION 3 – OPERA TION 3-1. Controls 1 Arc For c e ( D i g ) C o n t r o l For SMA W , control increases short-circuit amperage which allows the operator to use a very short arc length without sticking the electrode. Set control at 0 for GT AW .
OM-318 Page 16 SECTION 4 – MAINTENANCE & TROUBLESHOOTING 4-1. Routine Maintenance Y Disconnect power before maintaining. 3 Months Replace Unreadable Labels Repair Or Replace Cracked W eld Cables.
OM-318 Page 17 4-3. T roubleshooting T rouble Remedy No weld output; unit completely inoperative. Place line disconnect switch in On position (see Section 2-10). Check and replace line fuse(s), if necessary (see Section 2-10). Check for proper input power connections (see Section 2-10).
OM-318 Page 18 Notes.
OM-318 Page 19 SECTION 5 – ELECTRICAL DIAGRAM SC-187 701 Figure 5-1. Circuit Diagram.
OM-318 Page 20 SECTION 6 – P ARTS LIST Fig 6-4 Fig 6-3 Fig 6-2 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 25 26 27 19 28 25 ST-130 166-L 24 6 .
OM-318 Page 21 Replace Coils At Factory Or Factory Authorized Service Station Description Part No. Dia. Mkgs. Item No. Figure 6-1. Main Assembly Quantity 1 182 605 COVER, top 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-318 Page 22 1 5 7 9 10 9 10 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 15 16 22 ST-130 167-F 11 12 13 2 3 4 6 8 . Hardware is common and not available unless listed.
OM-318 Page 23 Description Quantity Part No. Dia. Mkgs. Item No. Figure 6-2. Panel, Front w/Components (Fig 6-1 Item 28) 1 169 136 PIN, handle 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-318 Page 24 Description Quantity Part No. Dia. Mkgs. 126 209 Item No. Figure 6-3. Rectifier , Si Diode (Fig 6-1 Item 27) 1 PLG53 1 15 092 CONNECTOR & SOCKETS 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
.
Warranty Questions? Call 1-877-HOBART1 for your local Hobart distributor. hobart standard 7/00 Service Y o u always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor or call 1-800-332-3281.
PRINTED IN USA 2000 Hobart Welding Products. 1/00 Hoba rt We lding Pr oducts An I l li noi s T ool W orks Com pany 600 West Main St reet Troy , OH 45373 USA For Technical A ssistan ce: Call1-800-3.
デバイスHobart Welding Products 300 ACの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hobart Welding Products 300 ACをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHobart Welding Products 300 ACの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hobart Welding Products 300 ACの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hobart Welding Products 300 ACで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hobart Welding Products 300 ACを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHobart Welding Products 300 ACの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hobart Welding Products 300 ACに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHobart Welding Products 300 ACデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。