WS-40/80 Hobart Compact Water Softener Installation Instructions WS-40 WS-80 - NOTICE - This Manual is prepared for the use of trained Hobart Service Technicians and should not be used by those not properly qualified. This manual is not intended to be all encompassing.
TABLE OF CONTENTS INSTALLATION ............................................................................................ 3 INSTALLATION WS-40/80 .............................................................................. 3 DISC REPLACEMENT .....
INSTALLATION INSTALLATION WS-40/80 SAVE THESE INSTRUCTIONS Disconnect the electrical power to the machine and follow lockout / tagout procedures. 1. Locate water supply line and appropriate drains for softener installation. 2. Install by-pass valving.
Fig. 5 9. Install one O-Ring into each groove of the brass adapter. Fig. 6 10. Apply a small amount of seal lube evenly onto each O-ring. Fig. 7 11. Remove the pin and bracket from the softener in/ out port area. Fig. 8 12. Install the brass adapters into the in/out ports and secure by reinstalling the bracket and pin.
15. Insert tubing provided into the overflow port on the back of the softener and run drain lower than the cabinet connection to provide a gravity drain in the event of a internal cabinet leak. Fig. 10 16. Review the meter disc selection chart and the water analysis provided.
Brine Valve Settings Unit Brine Setting Float Cup Height WS-40 1.0 lb. 6.25" WS-80 1.4 lb. 6.5" E. Reinstall brine valve into the cabinet. NOTE: Do not drop brine valve into drum. Dropping may lower float cup, resulting in an improper setting.
Fig. 17 27. Check for proper operation by pressing the recessed red button on bottom of salt alarm controller. If controller is operating properly - the indicator light will flash and an audible tone will be heard. Fig. 18 28. 29. Add a clean grade of salt at this time.
DISC REPLACEMENT DISC REPLACEMENT WS-40/80 1. Remove screws and cap cover from level one. Fig. 19 2. Remove balance piston. Fig. 20 3. Remove balance piston o-ring and balance piston spring. Fig. 21 4. Remove meter drive pawl. Fig. 22 5. Remove meter disc.
6. Install correct meter disc and reassemble in reverse order. NOTE: Be certain to start cap screws by hand rotating backwards until screw drops into thread then tighten. An alternating, crossing pattern should be used while tightening cap screws to ensure correct cap fit.
DISC SELECTION DISC SELECTION WS-40/80 The amount of hardness removed (in compensated gpg) will be based on the amount of brine and the meter disc selected. 1. Determine the compensated hardness. This requires a hardness test and an iron test on raw water at the application site.
デバイスHobart WS-80の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hobart WS-80をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHobart WS-80の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hobart WS-80の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hobart WS-80で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hobart WS-80を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHobart WS-80の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hobart WS-80に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHobart WS-80デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。