HollandメーカーMembraneの使用説明書/サービス説明書
ページ先へ移動 of 23
Membrane Switch Design Guide.
2 Introduction Membrane switch technology has become a reliable front panel solution where environmental concerns or frequent cleaning are an issue. The sealed nature of the technology coupled with its reliability and ability to offer tremendous aesthetic fle xibility make it the solution of choice for many industries.
3 specify type styles, colors, and sizes of all copy. Artwork should be provided to us fo r all logos or special symbols. We use the latest version of Autocad with Autoscript to generate our drawings and artwork. It is helpful for customers to supply us with an Autocad DWG file, or as an alternate, a DXF or IGES file.
4 Ultraviolet Hardcoats The most durable hardcoats are those that are cured by exposure to ultraviolet light. These coatings are called UV hard-coats. Hardcoats can be selectively added to many of the materials to produce parts with a velvet textured background, and gloss or anti-glare windows.
5 switch. Standard tolerances should be +/- .015". Tolerances of +/- .010 " can be held on critical dimensions such as the perimeter or cutouts. Hole center to hole center tolerances of +/- .005" can be held. Tolerances on very large parts will be greater.
6 considered when specifying shielding requirements. Tail Exit Point Flexible membrane switches are connected by means of a flexible tail that is cut from the circuit material. We have a great deal of flexibility in selecting the exit point. The tail cannot exit under or within .
7 Creasing of Flex Circuits In many applications the tail of a membrane switch needs to be bent at or near the exit point. Extreme caution should be exer cised when bending flex circuits.
8 sense to consider polyester domes if the total dome usa ge per order is expected to exceed 2500. A drawback of polyester domes is that they tend to relax and lose their tactile feel at elevated temperatures and are not recommended for applications that will experience temperatures above 55 ˚ C (131 ˚ F).
9 -45 ˚ C to + 75 ˚ C (See notes on polyester domes) Life Cycle Testing Holland Nameplate performs life cycle testing to insure tha t our customers have a realistic expectation as to the typical number of cycles a particular design ca n endure.
10 that will have insertable legends. An oversized pocket is put behind this clear area so that the legend card can be inserted and seen through the window. The entire overlay has the same texture, which helps hide the fact that legends are being viewed through a window.
11 Always clean the surface before installing a membrane switch. If alignment is difficult, we recommend that you remove a small corner of the backing, align the membrane switch, stick the corner down, bend back the membrane switch and rem ove the rest of the liner.
12 of the membrane switch. A sample of a simple drawing of a membrane switch is included in Appendix “C”. Appendix “D” is a glossary. Holland Nameplate Overlay Material Guide Appendix A Product ID Manufacturer Base Film Hardcoat Fini sh Embossable UL Rating Texturable Thickness Melinex 561 ICI Polyester No Gloss Yes No Rating Yes .
13 Holland Nameplate Membrane Switch Checklist Appendix B The following items need to be comm unicated to Holland Nameplate before an order can be processed.
14 ___ Customer Specified Shielding ___ None required ___ Printed silver grid ___ Printed carbon ___ Aluminum foil ___ Other ___________ _____ Overlay Material ___ Velvet textured polycarbonate (8B3 5.
15 Embossing ___ Key rims ___ Plateau ___ LED windows Hydroforming ___ Key rims ___ Plateau ___ LED windows Insertable legends ___ Not required ___ Specified Support panel ___ LED windows ___ Not requ.
16 Color matching ___ Custom (samples supplied) ___ Pantone Matching S ystem ___ Federal Standar d No. 595a ___ Copy size, style, and location specified Switch Sealing Requirements ___ Standard splash.
17 Membrane Sample Appendix C.
18.
19.
20.
21.
22 Glossary Appendix D Actuation Forc e- The maximum force measured pr ior to or including the point at which keypad contact closure is achieved. Alodine- A chemical conversion process that oxidizes alum inum to form a non-porous aluminum oxide. Referred to as “poor-man’s anodizing” because it is less costly and not as durable as anodizing.
23 Over lay- Top layer of a membran e switch (the graphic interface between devic e and user) generally made of polyester or polyc arbonate. Pad Emboss- A raised area on an overlay, which defines an entire graphic. (i.e., a full keypad of L.E.D. wind ow.
デバイスHolland Membraneの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Holland Membraneをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHolland Membraneの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Holland Membraneの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Holland Membraneで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Holland Membraneを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHolland Membraneの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Holland Membraneに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHolland Membraneデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。