Honeywellメーカー3580の使用説明書/サービス説明書
ページ先へ移動 of 60
Quantu m T ™ Omnidirectional Laser Scanner 3580 User’s Guide.
Disclaime r Honeywell Int ernational I nc. (“HII ” ) reserves the rig ht to make chan ges in specificat ions and other inf or mation cont ained in this d ocument wit ho ut prior notic e, and the reader shou ld in all cases co nsult HII t o determine wheth er any such changes hav e b een made.
ii T ABLE OF C ONTENTS Introductio n Product Overview ............................................................................................. 1 Scanner and Accessories .............................................................................
iii T ABLE OF C ONTENTS Design Specif ications ......................................................................................... 31 Applicatio ns an d Protocols ................................................................................. 33 Default Sett ings - Communic ation Param eters .
1 I NTRODUCTION The Quantum T ™ is a hands - free, om nidirecti ona l bar code s c anner with opt ional single - line sca nning capab ilities. It ut ilizes the po werful Honeywell Quantum E scan engine to pr ov ide an out s t anding scan perf ormance on all s t andard 1D barcode symb ol o gies, inclu ding GS1 DataBar™ (RSS) .
2 I NTRODUCTION Scanner and Accessories B ASIC K IT C OMPONENTS Part No. Descr iption MS35 80 Quantum T Omni Singl e - Line Scanner 00- 02026 Quantum T Omni Single - Li ne Scanner User ’s Guide * 00 - 02407 Met roSelect ™ C onf iguration Guide * * Guides also a v ai la ble for do w nload at www .
3 I NTRODUCTION Scanner and Accessories O PTIONAL A CCESSORIES Part No. Descr iption 54 - 54002x -3 Keyboard Wed ge P owerLink C abl e straight cord, s hort strain r elief 54 - 54020x -3 Stan d Alone .
4 I NTRODUCTION Scanner Components Figure 1. Scanner Components I TEM N O . D ESCRIPTION 1 Red Output Wi ndow (Laser A per t ure) 2 Pin Hole for Ca bl e R elease 3 10 - Pin RJ45, Fem al e Socket 4 Speaker 5 Blue and White LED Indicator s 6 Button 7 Protective Boot and Stand Co nne ction Never remove t he protect ive boot from t he MS3580.
5 I NTRODUCTION Caution and Serial Number Labels Figure 2. Labeling Example Caution To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements f or SELV ( S afety E xtra L o w V oltage) according to EN/IEC 60950 -1 .
6 I NTRODUCTION Mounting Specifications and Stand Assembly Pedestal Stand Figure 4. Pedestal Stand Assembly Optional Flex St and Figure 5. Assembly Components for Optional Flex Stand Item Description Qty. Item Description Qty 1 MS3580, Quan tum T 1 6 Flexible Shaft * 1 2 Pivot Cylinder 1 7 Base Plate Co ver 1 3 Bearing Plat e 1 8 #8 x 1.
7 I NTRODUCTION Mounting Specifications and Stand Assembly Optional Flex S t and Figure 6. Mounting Hole Detail fo r the Flex Stand Base Plate (Optional ) Figure 7.
8 I NSTALLATIO N RS232, RS232 TTL, Light Pen or Laser Emulation 1. Turn off the host device. 2. Plug the male 10 - pin RJ45 en d of the PowerLi nk cable i nto the 10 - pin socket o n t he MS 3580. 3. Connect the 9 - pin f emale end of the PowerLink ca bl e to the host d evice.
9 I NSTALLATIO N RS485 1. Turn off the host device. 2. Plug the male 10 - pin RJ45 en d of the MVC cable i nt o the 10 - pin socket o n t he MS3580 . 3.
10 I NSTALLATIO N Keyboard We dge 1. Turn off the host device. 2. Plug the male 10 - pin RJ45 en d of the PowerLink ca bl e into the 10 - pi n socket on the M S3580 . 3. Disconnect t he keyboard f rom the host device. 4. Connect the “ Y ” end of the Po werLink cable to the ke yboard and t he keyboard port on the host PC.
11 I NSTAL LATION Stand- Alone Keyboard 1. Turn off the host device. 2. Plug the male 10 - pin RJ45 en d of the PowerLi nk cable into t h e 10 - pin socket o n t he MS3580 . 3. Connect the ot her end of t he PowerLink ca bl e to the keybo ar d port on the hos t device.
12 I NSTALLATIO N USB 1. Turn off the host devi ce. 2. Plug the male 10 - pi n RJ45 end of the USB cable into the 10 - pin socket on the M S3580 . 3. Plug the other end of the USB interface cabl e into the host device’s USB port. 4. Turn on the ho st device.
13 S CANNER O PERATION Configurable Primary and Single Line Scan Pattern Modes There are t wo configurable sc an pattern m odes availab le with the MS35 80 . • The primar y scan pat tern mode is the default scan pattern act i v e when the scanner starts.
14 S CANNER O PERATION Configurable Button Functions S INGLE S CAN P ATTERN B UTTON C LICK M ODE WITH C ODE G ATE E NABLED For illustrati on purposes t he unit’s primar y scan patter n has been s et.
15 S CANNER O PERATION Configurable Button Functions S INGLE S CAN P ATTERN B UTTON C LICK M ODE WITH C ODE G ATE D ISABLED For illustrati on purposes t he unit’s pr im ary scan patt ern has bee n s.
16 S CANNER O PERATION Configurable Button Functions S INGLE S CAN P ATTERN B UTTON H OLD M ODE WITH C ODE G ATE E NABLED For illustrati on purposes t he unit’s * pr im ary scan patt ern has been se.
17 S CANNER O PERATION Configurab le Button Functions 5. To scan and t r ans mit additio nal bar codes, repeat steps 2 t hrough 4. 6. The primar y scan pattern will automatic ally reactivate aft er the button is released and n o bar code is pres ent in the scan f ield.
18 S CANNER O PERATION Configu rable Button Functions S ECONDARY S CAN P ATTERN B UTTON H OLD M ODE WITH C ODE G ATE D ISABLED For illustrati on purposes t he unit’s * pr im ary scan patt ern has be.
19 S CANNER O PERATION Audi ble Indicators When the MS3580 is i n operati on, it provides audible feedb ack to indic ate the status of the s c anner. Eight s et tings are avai lable for the t one of the beep (normal, 6 alt er nate tones and no tone).
20 S CANNER O PERATION Visual Indicators The Quantum T i s equi pped with a blue and white LED that indicate s the scanner’s state and the status of the current s can when the unit is in oper ation .
21 S CANNER O PERATION Failure Mode Indicators Flashing B lue and One Razzberry Tone This indicates t hat the scanne r has experien ced a laser s ubsystem fail ure. Return the unit to an authoriz ed service c enter for repai r . Flashing Blue and White and Tw o Razzberry Tones This indicates t hat the scanne r has experien ced a motor fai l ur e.
22 S CANNER O PER ATION Depth of Field Specifications* Normal Scan Zone Specificat ions are based o n a 0.33 mm (13 mil) bar c ode. Figure 14 . MS 3580 † Normal Depth of Field * All specific at ions are subjec t to change w i t hout notice. † MS 3580 s hown wit h pedestal s t and.
23 S CANNER O PERATION Depth of Field Specifications* Reduced Scan Zone Specificat ions are based o n a 0.33 mm (13 mil) bar c ode. Figure 15. MS 3580 † Reduced Depth of Field * All specific at ions are subjec t to change w i t hout notice. † MS 3580 s hown wit h pedestal s t a nd.
24 S CANNER O PERATION Depth of Field by Bar Code Element Width* Normal Scan Zone M INIMUM B AR C ODE E LEMENT W IDTH A B C D E F mm .13 .15 .19 .25 .33 .66 mils 5.2 5.7 7.5 10 13 26 Figure 16. Normal Scan Zone by Bar Code Element Wi dth * All specific at ions are subjec t to change w i t hout notice.
25 S CANNER O PERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone M INIMUM B AR C ODE E LEMENT W IDTH A B C D E F mm .13 .15 .19 .25 .33 .66 mils 5.2 5.7 7.5 10 13 26 Figure 17. Reduced Scan Zone by Bar Code Element Wi dth * All specific at ions are subjec t to change w i t hout notice.
26 S CANNER O PERATION IR Activation Range* Quantum T ‘s def ault power sa ve mode † is Las er OFF . This power save m ode turns the laser off after a configure d period of non - us e . Any movem e nt detected by the IR in the activation area will cause the scann er t o ex it power save m o de.
27 T ROUBLESHOOTING G UIDE The follo wing guide is for r eference purp os es only. Contac t a Honeyw ell representativ e to preserve t he limited warranty term s on page 48 . Symptoms Possible Cause(s) Solution All Interfaces The unit has n o LEDs, beeper or motor spin.
28 T ROUBLESHOOTING G UIDE Symptoms Possible Cause(s) Solution All Interfaces The unit scans a bar code, but locks up after the first sc an ( the white LED stays on ). The scanne r is configured to s upport some form of host handshakin g b ut is not receiving the si gnal.
29 T ROUBLESHOOTING G UIDE Symptoms Possible Cause(s) Solution All Interfaces Durin g power up the unit beeps 3 times. There is a non - volat ile RAM failure. Contact a servi ce representat ive. During power up the unit razzes continuousl y. There is a RAM or ROM failure.
30 T ROUBLESHOOTING G UIDE Symptoms Possible Cause(s) Solution RS232 Only The host is receiving dat a but the data do es not look correc t. The scanner a nd hos t may not be confi gur ed for the same int erface. Check that the s canner and the host are config ured for the sa me interface.
31 D ESIGN S PECIFICATIONS MS358 0 Operation al Normal Depth of Field: 19 mm - 273 mm ( .75"- 10.75" ) 0.33 mm (13 mil) bar code Reduced Depth of Field: 19 mm - 146 mm ( .75"- 5.75" ) Omni Scan Scan Speed: 1650 scan lines per second No.
32 D ESIGN S PECIFICATIONS MS3580 Mechanical Width: 63 mm (2.48") Depth: 50 mm (1.97") Height: 68 mm (2.68") Weight: 6 oz (170 g) Electrical Voltage Supply: 5VDC ± 0.25V Operating Power: 1.375 W Standby Power: 1.0 W Operating Current: 275 mA typical at 5VDC Standby Current: 230 mA typical at 5VDC DC Transformers: Class II; 5.
33 A PPLICATIONS AND P ROTOCOLS The model number on e ach scann er i nc l udes the scan ner number a nd f actory default commu nications pr ot ocol. S CANNER V ERSION I DENTIFIER C OMMUNIC ATION P ROT.
34 D EFAULT S ETTINGS - C OMMUNICATION P ARAMET ERS Many functio ns of the scanner can be "config ured" - that is e nabled or disa bled. The scanner is shipped from t he factory conf i gured to a set of default condi tions. The default par ameter of the s c ann er has an aster i s k ( * ) in the charts on t he following pa ges.
35 D EFAULT S ETTINGS - C OMMUNICATION P ARAMET ERS P ARAMETER D EFAULT USB RS232* OR RS232 TTL L IGHT P EN RS485 KBW L ASER E MULATION Expanded ID “]e0” * RSS Limited Enab.
36 D EFAULT S ETTINGS - C OMMUNICATION P ARAMET ERS P ARAMETER D EFAULT USB RS232* OR RS232 TTL L IGHT P EN RS485 KBW L ASER E MULATION Transmit UPC -A Check Digit * Transmit U.
37 D EFAULT S ETTINGS - C OMMUNICATION P ARAMET ERS P ARAMETER D EFAULT USB RS232* OR RS232 TTL L IGHT P EN RS485 KBW L ASER E MULATION Nixdorf ID LRC Enabled UPC Prefix .
38 D EFAULT S ETT INGS - C OMMUNICATION P ARAME TERS P ARAMETER D EFAULT USB RS232* OR RS232 TTL L IGHT P EN RS485 KBW L ASER E MULATION Supplements are not Required * Two Digi.
39 C ONFIGURATION M ODES T he MS3580 Series scanner has t hree modes of configurat ion. • Bar Codes The MS3580 can be co nfigur ed b y scanning t he bar codes inclu ded in the Single - Line Co nf iguration Gu ide or the Su ppl emental Conf i guratio n G uide.
40 U PGRADING THE F IRMWARE The MS3580 is part of Honey wel l ’s line of sc ann ers with fla sh up gradeab le firmware. T he upgrade proce s s requires a ne w firmware file supplied to the customer by a c ustomer servi ce representat ive and Ho ne ywell’s Met roSet 2 software .
41 S CANNER AND C ABL E T ERMINATIONS Scanner Pinout Connections The MS3580 scann er interfac es terminate t o a 10 - pin mod u lar socket. The serial # la bel i ndicates t he interface e nabled when the scanner is s hipped from the fact or y. Figure 19.
42 S CANNER AND C ABL E T ERMINATIONS MS3580 - 11 RS485 Pin Function 1 Ground 2 RS232 Trans m it Output 3 RS232 Receiv e Input 4 RTS Output 5 CTS Input 6 DTR Input 7 IBM B -Transmit 8 IBM A+ Receive 9.
43 S CANNER AND C ABL E T ERMINATIONS Cable Connector Configurations (Host End) “Standard” Po werLink Ca ble M LPN 59 - 59000 x - 3 straight Pin Function 1 Shield Ground 2 RS232 Trans m it Output .
44 S CANNER AND C ABL E T ERMINATIONS Cable Connector Configurations (Host End) Keyboard Wed ge PowerLink C abl e 54 - 54002 x -3 Pin Function 5- Pin DIN, Female 1 Keyboard Cloc k 2 Keyboard Dat a 3 N.
45 R EGULATORY C OM PLIANCE Safety ITE Equipme nt IEC 60950-1: Second Editi on EN 60950-1: Second Edition Laser Laser Class 1: IE C 60825-1: Second Edition, 2007 EN 60825-1: Second Edition, 200 7 LED .
46 R EGULATORY C OM PLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 NOTE: Immunity pe rformance i s not guara nteed for s canner cable s greater tha n 3 meters in length w hen fully ex tended.
47 R EGULATORY C OM PLIANCE EMC Changes or modifications not expres sly approved by the party respo nsible for compliance could void the user’ s authority to operate the equipme nt.
48 L IMITED W ARRANTY Honeywell Int ernational I nc. ("HI I ") warrants i ts products an d optional accessories t o be free from de f ects in materia ls and workma nship and to conform to HII ’s published sp ecificati ons applicabl e to the product s purchased at the time of ship ment.
49 L IMITED W ARRANTY All provisio ns of this Lim i t ed Warrant y are separat e an d severab le, which means that if any provi sion is held i nv alid and une nforceable, s uc h determinat ion shall not affect t he v al id ity of enfor c eabilit y of t he other provis ions hereof .
50 I NDEX A AC ....................................... 2, 8 – 12 Accessories ............................... 2, 3 Adapter ........................................ 10 Audible Indic at or . 13, 19 – 21, 27 – 30, 40 B Bar Code ....... 19 – 21, 27 – 30, 31, 39 Bar Width .
51 I NDEX M Maintenance .................................. 3 Manual ............................... 2, 19, 33 Meteor ......................................... 40 MetroSelect ................................ . 39 MetroSet2 .............................
52 C USTOMER S UP PORT Technical Assistance If you need assi s t ance install ing or troubl es hooting yo ur device, pl eas e contact us by using one of the methods bel ow: Knowledg e Base: www.hsmkno wledgebase. com Our Knowledg e B as e provide s thousands of im m edi ate solu t ions.
.
.
.
Honeywell Sca nning & Mobility 9 680 Old Baile s Road Fort Mill, SC 2970 7 www.honey wellaidc.com 00 - 05090 Rev F 6/12.
デバイスHoneywell 3580の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Honeywell 3580をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoneywell 3580の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Honeywell 3580の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Honeywell 3580で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Honeywell 3580を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoneywell 3580の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Honeywell 3580に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoneywell 3580デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。