Dolphin ® eBase Communication Cradle for the Dolphin ® 9700 Mobile Computer User’s Guide.
.
1 Introduction The Ethernet Base (eBase) enables a single Dolphin 9700 computer to communicate with a host device over an Ethernet network. We recommend use of Hone ywell peripherals, pow er cables , and power adapters. Use of an y non-Honeywell peripherals, cables , or power adapters ma y cause damage not cov ered by the warr anty .
2 Software Requirements Before you connect the Dolphin terminal to the eBase, make sure you have the most current software installed. To check the terminal’s system information, tap Start > Power Tools > SysInfo . • The Kernel version must be 20.
3 Hard ware Over view Front P anel Terminal Well Place the terminal in this well to communicate with a host device, power the terminal, and charge the installed battery pack. The eBase completely charges the main battery in a Dolphin terminal in 4 hours.
4 AUX Battery LED The AUX Battery LED indica tes the status of the battery charging in the auxiliary battery well; see Back Panel on page 6. COMM LED The COMM LED indicates the status of data transfer between the Dolphin terminal and the eBase. This color means… Orange The auxiliar y battery is charging.
5 When the Dolphin terminal is docked: This color and status means… Red Solid No connection is established betw een the eBase and terminal. Orange Solid RASMan is attempting to establishing a connection between the eBase and the terminal. Green Solid RASMan has established a connection between the ebase and the terminal.
6 Back P anel Auxiliary Battery Well The eBase enables you to charge an additional Li-ion battery pack independently of the terminal well in 4 hours. This feature ensures that you can always have a fully charged battery for your terminal.
7 USB Port This USB Port is full-speed and 2.0 compliant. Using a USB cable, you can connect the eBase to a USB compliant device to facilit ate USB communication to and from the terminal.
8 Bottom P anel For details on how to mount the eBase, see Mounting on page 25. Reset Button Compliance Label Serial Number Label.
9 Po w e r The terminal requires 9.5 Volts DC input for communications and battery charging; the power adapter on the power cable converts the voltage from the power source to 9.5 volts DC. Only the Honeywell 9.5 VDC, 4A power supply provided with the ebase converts the voltage appropriately.
10 Charging the Main Battery in the Te r m i n a l We recommend use of Hone yw ell Li-Ion battery packs. Use of any non-Hone ywell batt ery may result in damage not cov ered by the warranty . The eBase provides power to the Dolphin terminal and allows the charging of the terminal’s main battery.
11 Ethernet Communication Setting up the eBase 1. Plug the power cord into the power adapter. 2. Plug the power connector cable into the power connector on the back of the eBase. 3. Plug the A/C power cord into a standard wall outlet. The COMM LED flashes red.
12 3. Remove the check from the box next to, “ Synchronize all PCs using this connection” . Tap OK . 4. Insert a Dolphin terminal into the terminal well. The DOCK LED lights green. 5. On the Dolphin terminal, tap Start > Power Tools 6. Click the RASMan icon once.
13 7. When the connection is established between the Dolphin terminal and the eBase, the terminal plays a sound, and the COMM LED on the eBase lights green. The connection icon in the Dolphin’s navigation bar changes from to . 8. Upon connection, the Dolphin terminal shares the eBase IP address.
14 Displaying the eBase and T erminal IP Address Once the Dolphin terminal has be successfully connected to the eBase, the terminal shares the eBase IP address. 1. Tap Start > Power Tools > Network Utilities > IPConfig . 2. On the Input tab, tap the Display full configuration button.
15 7. Tap on Connection in the Key column, and then tap File > Disable . 8. Tap OK, and then tap Yes to save your changes. Modifying the RASMan A utoActiveSync Setting 1. Tap Start > Power Tools > EZConfig Utilities > RASMan . 2. Select Settings from the folder tree, and then tap AutoActiveSync under the Key column.
16 Configuring the Network By default, the eBase is conf igured to obtain IP addresses automatically via DHCP server. This means that in most cases you would simply pl ug-and-play the unit. If necessary, you can use the Cradle Manager configuration utility for dynamic network configuration.
17 5. The Cradle Manager window opens. Note: Under General Settings, t he HTTP Port defaults to 80..
18 Changing the P ass word You can change the password from the Cradle Manager window. 1. Under General Settings, select the check box next to, “ Change Password” . 2. Enter the new password in the New Password field. 3. Click Apply at the bottom of the screen.
19 Changing the Dynamic Network Settings You can modify the Dynamic Network settings from the Cradle Manager window. 1. Under IP Settings, select Dynamic . 2. Enter the new settings in the fields supplied. Note: The default reboot time if missing an IP address is 60 seconds.
20 USB Communication Dolphin terminal’s support USB communication out of the box. The eBase also suppor ts USB communications using the USB port located on the back panel of the eBase. The eBase acts as a USB device by interfacing the USB signals of the Dolphin termina l to the USB of the host workstation.
21 8. The connection icon in the Dolphin’s navigation bar changes from to it indicate a successful connection. The eBase c an now transfer data between the terminal and the host device.
22 2. Locate the reset button on the bottom of the eBase. 3. Push in and hold down the reset button. 4. While holding down the re set button, plug in the power cable. 5. Wait 15 seconds, and then release the button. Note: When the factory defaults are restored, the password reverts to the default password, < Dolphin >.
23 2. Connect the host workstation Ethernet cable to a port on the same Ethernet subnet as the eBase. If the eBase is connected to a hub (or router), connect the host workstation to an available port on the same hub. 3. On your host workstation, open the web browser.
24 8. Enter the IP address of the server in the TFTP Server IP Address field. 9. Under File Name , enter the eBase firmware upgrade file name. 10. Click Apply . 11. Click OK , when prompted to reboot the EULink bridge. The COMM LED on the eBase flashes red during the reboot process.
25 Mounting Set the eBase on a dry, stable surface, such as a desktop or workbench near an electrical outlet. Be sure to provide enough workspace with good lighti ng for the user to view and operate the Dolphin terminal while it is in the eBase.
26 T echnical Assistance Contact information for techni cal support, product service and repair can be found at www.honeywellaidc.com . Limited W arranty Refer to www.honeywellaidc.com/warranty_information for your product’s warranty information. Disclaimer Honeywell International Inc.
27 T rademarks Dolphin, eBase are trademarks or registered trademarks of Hand Held Products, Inc. or Honeywell International Inc. Microsoft, Windows, Windows Mobile, Windows XP, Windows Vista, Windows 7, Ac tiveSync, Windows Mobile Device Center, Outlook, and the Windows logo are trademarks or registered trademarks of the Microsoft Corporation.
.
.
Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com E-NETBA S E- UG R e v A 97-EBASE-UG Rev A 6/10.
デバイスHoneywell 9700の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Honeywell 9700をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoneywell 9700の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Honeywell 9700の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Honeywell 9700で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Honeywell 9700を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoneywell 9700の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Honeywell 9700に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoneywell 9700デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。