CONVERSION WIRING DIAGRAMS FOR BC7000L1000 The diagrams and instructions contained in this booklet are for converting the following model programmers to BC7000 Microcomputer Based Burner Control System. TABLE OF CONTENTS Page Section l . . . . . . . .
SECTION I FIREYE C, D, E-SERIES CONTROL 120 V ONLY DIRECTIONS: 1. Disconnect all power to programmer. 2. Remove old programmer from subbase (trade-in to Honeywell Authorized Flame Safeguard Distributor). 3. Mark all wires on subbase; i.e., wires connected to terminal “D” should be marked “D.
E1214A FIREYE 70D10/26CF6-5022/26 CU6-5065 EP160/EP161/EP170 TO BC7000L/PM720L2004 or 1030.
E1215B FIREYE 24CJ5 - 5010/5011/3010/3011 25CU6 5062/5063/RS-2E 70D30/26CF6 5020/5021/1010/1011 EP380/EP381/EP390 TO BC7000L/PM720M2002.
E1216E FIREYE 24CJ5 5015 70D20/26CF6 5023/25 CU65055 EP260/EP261/EP270 TO BC7000L/PM720G2005.
SECTION II FIREYE P-SERIES CONTROLS 120 V ONLY DIRECTIONS: 1. 2. 3. 4. 5. 6. 7. 8. Disconnect all power to programmer. Remove old programmer from subbase (trade-in to Honeywell Authorized Flame Safeguard Distributor). Mark all wires on subbase; i.e., wires connected to terminal “D” should be marked “D.
E1221A FIREYE 26RJ8 1016, 1016T 26RJ8 1012, 1012T, 6012, 6012T TO BC7000L + PM720G2005.
E1693 FIREYE 25RLJ84580 TO BC700L + PM720L1030.
E1217B FIREYE 25RU8 6560, 6570,6580 26RJ8 6060, 6070,6080, 6160 TO BC7000L + PM720L1030.
E1218A FIREYE 29RF5 1001, 1009, 6009 TO BC7000L + PM720G2013.
E1219A 26RJ8 6058, 6066, 6068 25RU8 6558, 6566 TO BC7000L + PM720G2005.
E1220A FIREYE 26RJ8 1002, 1003, 1008, 1011, 1018, 6008, 6018 29RF5 1000, 1002, 1005, 1015, 1104 29RF5 6015 TO BC7000L + PM720G2005.
SECTION Ill HONEYWELL R4126, R4127, R4181 CONTROLS 120 V ONLY DIRECTIONS: 1. 2. 3. 4. 5. 6. 7. 8. Disconnect all power to programmer. Remove old programmer from subbase (trade-in to Honeywell Authorized Flame Safeguard Distributor). Mark all wires on subbase; i.
E1222A R4126A1172, 1180,1198 TO BC7000L + PM720L2004.
E1223A R4126A1008, 1016, 1024, 1032, 1040, 1057, 1081, 1149 R4126B1006, 1014, 1022 TO BC7000L + PM720G2005.
E1224A R4126A1073,1164 TO BC7000L + PM720L2004.
E1753 R4127A1155 AND R4127A1197 TO BC7000L + PM720G2005.
E1225A R4127 (ALL MODELS) EXCEPT R4127A1171, R4127A1155, R4127A1197, R4127B1039, AND R4127B1047 TO BC7000L + PM720G.
E1724A R4127A1171/R4127B1039/R4127B1047 TO BC7000L+PM720G2005.
E1226A R4181A1000, R4181A1026 TO BC7000L + PM720G2005.
E1227A R4181A1018, R4181A1034 TO BC7000L + PM720L2004.
E1228A R4181A1042, R4181A1059 TO BC7000L + PM720L2004.
SECTION IV HONEYWELL R4140 AND R4150, 20 TERMINAL SUBBASE 120 V ONLY NOTE: This cross reference does not include conversions for proprietary controls such as Cleaver Brooks, Vapor or Peabody Gordon Piatt models.
REPLACING AN R4140M OR R4150M WITH START INTERLOCKS WITH A BC7000L/PM720M2002 *-X x x ;.-” .“. STEPS FOR CONVERSION 1. START INTERLOCKS BECOME PREIGNITION INTERLOCKS. 2. DISCONNECT DAMPER CONTROL WIRE FROM TERMINAL 10 CONNECT IT TO TERMINAL 11. 3.
E1237 REPLACING AN R4140M OR R4150M WITH PREIGNITION INTERLOCKS WITH A BC7000L/PM720M2002 2. DISCONNECT DAMPER CONTROL WIRE FROM TERMINAL 10 AND CONNECT IT TO TERMINAL 11. 3. 4. 5. REMOVE JUMPER FROM TERMINAL BETWEEN TERMINAL 11 AND 12 (on some models).
REPLACING AN R4140G OR R4150G WITH START INTERLOCKS WITH A BC7000L/PM720G2005 /PM720G2013 t * BC7000L/PM720G2005 /PM720G2013 STEPS FOR CONVERSION 1. START INTERLOCKS BECOME PREIGNITION INTERLOCKS. 2. 3. 4. FOR PM720G2005 ONLY JUMPER 15 TO 8 FOR 30-SECOND TRIAL FOR MAIN FLAME AT TERMINAL NO.
REPLACING AN R4140G OR R4150G WITH PREIGNITION INTERLOCKS WITH A BC7000L/PM720G2005 /PM720G2013 #f-----+--- -., ,,, ,):.> ?>., E.,li:,. ~ FOR PM720G20050NLYJ”MPER8T0 15 FOR3CISECCZNDTRIAL FOR ( +- ————=—=— —$==$ — Ji >: c, .
REPLACING AN R4140L OR R4150L WITH A BC7000L/PM720L1030 /PM720L2004 L /-.., ‘-4 ~VJIRllUG CHANGE NOT NECESSARY FOR PM720LI030 BC7000L/PM720L1030 /PM720L2004 1. 2. 3. STEPS FOR CONVERSION IDENTIFY AND REMOVE BURNER CONTROLLER AND LIMITS CIRCUIT WIRE FROM TERMINAL NO.
SECTION V 1. 2. 3. 4. 5. 6. 7, REPLACING R4150 MODELS WITH 13- OR 15-TERMINAL SUBBASES Disconnect all power to programmer. Remove R4150 from subbase (trade-in to Authorized Distributor). Mark all wires on subbase; i.e., wires connected to terminal “9” should be marked “9”.
E1229A CONVERSION FOR R4150A, B, AND C MODELS 120 VOLT ONLY USE BC7000L/PM720M2002.
E1230A CONVERSION FOR R4150G1004, G1020, G1046, G1103, G1111, G1145, G1178 MODELS 120 VOLT ONLY USE BC7000L/PM720G2013.
E1231A CONVERSION FOR R4150G1012 AND G1079 MODELS 120 VOLT ONLY USE BC7000L/PM720M2002.
E1232A CONVERSION FOR R4150M USE BC7000L/PM720M2002.
デバイスHoneywell BC7000L1000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Honeywell BC7000L1000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoneywell BC7000L1000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Honeywell BC7000L1000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Honeywell BC7000L1000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Honeywell BC7000L1000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoneywell BC7000L1000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Honeywell BC7000L1000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoneywell BC7000L1000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。