HoneywellメーカーCT1501の使用説明書/サービス説明書
ページ先へ移動 of 20
CTl500, CT1501, CT1502, CT1503 ELECTROMECHANICAL FUEL SAVER THERMOSTAT AND WALLPLATEEUBBASE CTI500-24 V gas or oil heat. CTl501-24 V gas or oil heat/cool. CTI502--24 V central electric heat/cool or single stage heat pump without auxiliary heat. CTI 503-750 millivolt heat.
THERMOSTAT FEATURES I-Front of thermostat. HlGH TEMPERATURE CONTROL LEVER (RED) 1 LOW TEMPERATURE CONTROL LEVER (BLUE)- 11.711 'THERMOSTAT THERMOMETER 1 COVER Il-Hinged cover lifted. .. .~ . ,..... . "--- PROGRAM PINS A Ill-Cover removed. 24 HOUR PROGRAM DIAL ANTICIPATOR HIND THERMOSTAT.
k PREPARATION ((1 "1 THERMOSTAT MODEL CT1500 CT1501 CT1502 SUBBASE OR 199986C Wallplate Q682A1079 Subbase Q682B1227 Subbase WALLPLATE INCLUDED FOR USE WITH 2-wire, 15 to 30 volt control circuit For gas or oil heating system. 4- or 5-wire, 15 to 30 volt control circuit For gas or oil heating/cooling system.
If wallplate or subbase is mounted on a vertical outlet box (check old installation), order 196393A Cover Plate and Adapter Ring (see appro- priate figure under step 4). Call Honeywell Consumer Services (1 -800-468-1 502) for ordering information, Monday-Friday, 7:30 a.
F REMOVE OLD THERMOSTAT 0 “3 Remove cover of old thermostat. If the cover 0 doesn’t snap off when pulled firmly from the bottom, check for a screw that locks the cover on. Before removing the old thermostat from the 0 wall, look at it carefully to locate the heat anticipator adjustment mechanism.
b MOUNT WALLPLATE OR SUBBASE 10 “4 If mounting on outlet box, mount as shown on appropriate figure. If mounting on wall, hold wallplate or sub- base in position and mark holes on wall. Use spirit level to make sure wallplate or sub- .’ .. base will be level.
n Carefully level the wallplate or subbase and firmly u tighten screws. .. SPIRIT LEVEL ‘‘wm WALLPLATE SCREWS “2) 5 69-0273-9.
WIRE WALLPLATE OR SUBBASE MOTE: All wiring must comply with local electrical Refer to illustration and strip thermostat wire insulation as necessary. codes and ordinances. 0. : F"rn ~STFldilRUT . -. . - . . .. . . CONNECTION- - FOR WRAPAROUND BARRIER CONNECTION- STRlP7116In.
For CT1501 heating/cooling Connect the wires to matching terminals on the subbase. 4-WIRE SYSTEM U U 5-WIRE SYSTEM I I I I RELAY OR CONTACTOR VALVE COIL I I 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND M2&13 NOTE: If there are four wires, connect wire marked R to terminal RH and add a jumper wire to connect to RC.
OLDSUBBASE TERMINAL R or RH RC W Y G B 0 P Push excess wire back into wall. and plug hole in wall with nonflammable insulation to prevent drafts from affecting thermostat operation. CONTROL FUNCTION Heating transformer power to control circuit Cooling transformer power to control circuit.
CT1502, continued SINGLE STAGE HEAT PUMP (WITHOUT AUXILIARY HEAT) SYSTEM I- -1 For CT1503 750-millivolt heating Connect either wire to R terminal and the other wire to W terminal. Firmly tighten screws. Push excess wire back into wall, and plug 0 hole in wall with nonflammable insulation to prevent drafts from affecting thermostat operation.
- L MOUNT THE THERMOSTAT or subbase as shown in illustration. Do NOT cycle heating system until Step 7 is completed. 10.
- SET HEAT ANTICIPATOR LEVER NOTE: Not applicable on CT1503 millivolt model. The thermostat's adjustable heat anticipator 0 must be correctly set to accurately control the on-time length of the system. An incorrect setting can result in room temperature swings or burn out the anticipator and void the thermostat warranty.
On the CT1500. CT1501 or CT1502 thermo- stats, move the heat anticipator indicator to match the number you recorded in Step 4 or found on the primary control as shown above, or as recorded in Step 7 ANTICIPATOR 11,7164 SETTING LEVER INSTALL TIMER F BATTERIES 0 “8 teries in thermostat as shown.
SET TIMER Adjust the timer by moving the knob in 0 clockwise direction. Do NOT reverse the knob. When time is correctly set, the Time Indicator Arrow (see illustration) must point to the correct time and the corresponding daytime (lighr) or nighitime (dark) portion of the program dial.
I- ATTACH THERMOSTAT COVER 0 “10 Make sure the packing inserts in the thermo- 0 stat base have been removed. as explained in step 3 Place the two tabs on upper edge of cover into mounting slots in thermostat base Swing cover downward until it engages 0 0 catch at bottom of base .
CHECK OUT THERMOSTAT OPERATION AND SET TEMPERATURE CONTROL b LEVERS cn il 1 The two levers on top of the thermostat control the low and high temperature for energy savings and comfort control, as shown in illustration.
Heating-only System 0 Turn on power to the furnace. 0 Push both temperaturecontrol leverstogetherat least 5" F [3" C] above room temperature. The heat should comeon.Thefan will startwhen the furnace heats up. 0 Move both levers5" F [3" C] below room temper- ature.
0 After checkout, reset both temperature levers to desired temperatures. For heating season: [? Move the blue lever to the energy savings temperature you want when you are sleeping or your home is not occupied. 0 Setthered levertothetemperature you want for normal comfort periods.
Honeywell Residential and Building Controls Division 740 Ellesmere Road Scarborough, Ontario M1P 2VY Helping You Conlrol Your World Residential and Building Controls Division Honeywell Inc.
デバイスHoneywell CT1501の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Honeywell CT1501をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoneywell CT1501の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Honeywell CT1501の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Honeywell CT1501で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Honeywell CT1501を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoneywell CT1501の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Honeywell CT1501に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoneywell CT1501デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。