MagicSta t ® CT3200 Pr ogrammab le Thermos tat Installat ion and Progr amming Instr uctions We l c o m e to the w orld of co mf ort and energ y s a vings with y our ne w Hone yw ell MagicSta t ® Progr amm ab le Thermosta t.
2 INSTALLATION 69-0 653-6 Installat ion V erify that y ou have the ri ght thermostat Mak e su re that the CT3200 i s the righ t thermostat f or your h eating /cooling syst em. Rea d the com patibi lity cha r t belo w to determine wh ich system y ou ha v e.
69-0653-6 INSTALLATI ON 3 Step 1. Prepare f or instal lation a. Careful ly unpac k your n ew t hermostat. Sa ve y our rec eipt and mak e sure you hav e the f ollo wing par ts: b . Gather t he needed tools and s upplies listed below . c. Mak e sure that your heatin g and coo ling s ystems are working properly .
4 INSTALLATION 69-0 653-6 Step 2. Remove the old ther mostat Fig . 2 Fig . 3 Fig . 4 WIRES THROUGH WALL OPENING M20133 a. T urn off power to the heating/c ooling s ystem, e ither at the furnace or at th e fuse/ circu it break er pa nel. b . Remo v e the co ver of y our old thermosta t (Fig.
69-0653-6 INSTALLATI ON 5 Step 3. Install the mounting plate Fig . 5 Fig . 6 Fig . 7 M20128 W R G R c Y a. Separ ate th e mountin g plat e from the thermostat us ing a co in, as sho wn in Fig 5. b . P osition the mount ing plate on the wall . Be sure th e mou nting plate s its flush again st the w all and none of the wi res are trap ped behi nd it.
6 INSTALLATION 69-0 653-6 Step 4. Set the t hermostat for y our type of heating system a. Use the FUEL SWITCH on the back of the th ermostat to set yo ur ne w thermosta t f or the ty pe of f uel that y our heating system us es: F – gas or oil, or E – ele ctr ici ty .
69-0653-6 INSTALLATI ON 7 Heat ing Syst em T ab le Note : Settin g the sc rew “ out one turn ” means tu r nin g the screw 36 0 ° counter-cl ock wise, o r one c omplete t urn. Step 5. Wire t he thermostat terminals T ype of sys tem Scre ws A and B Fuel s witch W ar m air , gas, o r oil heating system with an effi ciency ratin g unde r 90%.
8 INSTALLATION 69-0 653-6 Step 6. Mount the t hermostat Step 7. Inst all the batt eri es a. A lig n th e ta bs at the top of the thermostat wi th the t abs at the top of the mounting plate (Fig. 11). b . Press the lo wer edge of t he case t o latch th e bottom o f the thermostat (Fig.
69-0653-6 INSTALLATI ON 9 Special wiring inst ructions A cloc k thermostat with C or C1 terminals A cloc k thermostat has o ne or tw o e xtra wires attached to the C or C1 terminals that a llow the cloc k to oper ate.
10 INSTALLATION 69-0 653-6 M20127 JUMPER (FACTORY- INSTALLED). REMOVE IF 5-WIRE SYSTEM R R c WY G Five wires connect ed to t he old th ermostat Y our ne w ther mostat has a f actory-installed m etal j umper betw een the R and Rc terminals (Fig. 15). Remo ve the ju mper bef ore wiring the R an d Rc terminals .
69-0653-6 PROGRAMMING 11 Fan Auto On System Cool Off Heat Set Schedule Set clock/Day Back Back Ahead Ahead Cooler Cooler W armer W armer Hold Temp Run Program SYSTEM ON TEMPORARY Temp Time AM PM MO TU.
12 PROGRAMMING 69-0653-6 Ste p 1. Se t the cu rr ent t im e an d day Step 2. Learn about the pr ogramming featur es Y our 320 0 thermostat al lows y ou to prog ram sched ules f or both a hea ting s eason and a coo ling sea son.
69-0653-6 PROGRAMMING 13 Pr ogramming tips • Y ou do not need to progr am times and te mperatu res for al l program periods . If y ou dec ide not to prog ram y our thermostat, it w ill auto matic ally co ntrol he ating at 6 8 ° F (20 ° C), and co oling at 7 8 ° F (26 ° C), 24 h ours a da y .
14 PROGRAMMING 69-0653-6 Step 3. Progr am the heating schedule a. Write in t he times and temp eratures tha t you wan t to pro gram f or y our hea ting sch edule . Heating Schedule Pr ogram peri od W AKE LEA VE R ETURN SLEEP Sugg ested Settings Time 6:0 0 AM 8:00 AM 6:00 PM 10 :00 PM Te m p 70 ° F (21 ° C) 62 ° F (16.
69-0653-6 PROGRAMMING 15 Step 4. Progr am the cooling schedule a. Write in t he times and te mper atures tha t y ou w ant to pro gram f or your co oling sc hedule . Cooling Schedule Pr ogram peri od W AKE LEA VE R ETURN SLEEP Sugg ested Settings Time 6:0 0 AM 8:00 AM 6:00 PM 10 :00 PM Te m p 78 ° F (25.
16 PROGRAMMING 69-0653-6 b . Set the Sy stem s witch to COOL. c. Re peat st eps 3c. t hrough 3k. to prog ram the w eekd a y and w eekend c ooling schedul e. Step 5. Check out the system V erify that y our heating system wor ks a. Set the Sy stem s witch to HEA T , and the F an swi tch to AU T O.
69-0653-6 OPERATION 17 Operation Chan g e th e clock for Daylig ht/S tand ard time a. P res s onc e. The t ime is d ispla yed. b . Press an d hold or until the c orrect time is displa yed. c. Pr ess on ce. The curre nt time a nd da y and the curre nt temper ature are displ a ye d.
18 OPER ATION 69-0 653-6 Replace t he batt eries As the ba tteries run lo w , y our thermostat sho ws the f ollow ing in th e digi tal displ a y: a. Mak e su re that the System s witch is set in the OFF p ositio n. b . Open the b attery door . c. Press on the le ft side of the ba tteries to re mov e them.
69-0653-6 OPERATION 19 Override the pr ogram settings Note: Mak e sure the System s witch i s set to either HEA T or COOL be f ore maki ng any c hange s to the sch edu le. Change t he temperat ure temporari ly Pres s or until the desired tem perat ure is displayed.
20 OPER ATION 69-0 653-6 Check the current programmed te mperature Pres s to displ a y the tem per ature th at is prog ram med f or the current progra m period. The SET indicator dis pla ys briefly al ong with the pro gr ammed te mper ature (Fig. 29).
69-0653-6 FREQU ENTLY AS KED QUE STIONS 21 Frequentl y asked questions If... Then... Display will n ot come on • Mak e sure the batteries are fresh a nd ins talled c orrectly . • Set the Sys tem s witch to OFF . Remov e the batteries an d then inser t them back ward s f o r fiv e to ten seco nds to res et the thermo stat.
22 FREQUE NTLY AS KED QUEST IONS 69-0653-6 Customer ass istance F or all questions c oncerning th is thermostat, ple ase rea d and f ollow the instructions . If you nee d addit ional ass istance , call Hone ywell Cu stomer R elations at 1-80 0-468-1502 , Mond ay – Fr i d ay, 7 : 0 0 AM – 5:30 PM Central T ime, or visit us a t www .
69-0653-6 FREQU ENTLY AS KED QUE STIONS 23 Limited warranty Honeywell w arrants this product, e xcluding batter y , to be free from def ect s in the workmanship or materials, under normal use a nd ser v ice, f or a period of one (1) y ear from the date of purchase b y the consumer .
Home and Building Contr ol Honeywell 1985 D oug las Dr ive Nor th Golde n V alley , MN 554 22 69-0653-6 R e v . 9 -01 Home and Building Co ntrol Hone ywe ll Li mited – H oney well Limi t é e 35 Dynami c Driv e Scar bo rough , On tar io M1V 4Z9 Printed in the U .
デバイスHoneywell CT3200の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Honeywell CT3200をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoneywell CT3200の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Honeywell CT3200の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Honeywell CT3200で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Honeywell CT3200を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoneywell CT3200の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Honeywell CT3200に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoneywell CT3200デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。