® U.S. Registered Trademark Copyright © 2002 Honeywell All Rights Reserved 69-0274-6 Verify that you have the correct thermostat Using the compatibility chart below , verify that you purchased the correct CT87 Thermostat for your heating/cooling system.
CT87A,B,J ROUND® THERMOSTAT 69-0274-6 2 Prepare for installation 1. Carefully unpack your new thermostat; rough handling may affect it s accuracy . Save your receipt and identify the following parts: • CT87 Thermostat • Screws: two 1-in. sheet metal screws, two 1/2-in.
CT87A,B,J ROUND® THERMOSTAT 3 69-0274-6 5. Label the wires using the wiring labels that came with the CT87. Identify each wire using the letter of the terminal on th e old the rmo- stat (Fig.
CT87A,B,J ROUND® THERMOSTAT 69-0274-6 4 1. If using the cover ring: Position the cover ring again st the wall so that the arrow in the middle of th e cover ring is pointing up. 2. Position the wallp late or subbase . • If using cover ring : Place the wallplate/subbase over the cover ring.
CT87A,B,J ROUND® THERMOSTAT 5 69-0274-6 1. Place the cover ring against the outlet box so that the arrow in the middle of the cover ring is pointing up.
CT87A,B,J ROUND® THERMOSTAT 69-0274-6 6 Wire the thermostat 1. Use the wiring cross-reference table below to match each old thermostat wire with its corresponding terminal on the CT87 wallpl ate or subbase. See Fig. 8 through 13 wiring diagrams. *Never attach wires to both the B and O terminals.
CT87A,B,J ROUND® THERMOSTAT 7 69-0274-6 Fig. 8. CT87A for a 2-wire heat ing only system. Fig. 9. CT87A for a 3-wire hot water heating only system . Fig.
CT87A,B,J ROUND® THERMOSTAT 69-0274-6 8 Fig. 1 1. CT87B for a 5-wire heating /cooling system. Fig. 12. CT87J for a 4-wire single stage heat pump. Fig.
CT87A,B,J ROUND® THERMOSTAT 9 69-0274-6 Mount the thermostat 1. Pull off the thermostat cover and discard the red plastic insert that holds the mercury switch in place during shipping. 2. Using a pencil po int, slide the heat anticipator indicato r to 1.
CT87A,B,J ROUND® THERMOSTAT 69-0274-6 10 Set the heat anticipator for your system IMPORT ANT : Setting th e heat anticipator allows the thermostat to maintain accurate temperature control. 1. Using a pencil point, move the heat anticipator pointer to the numbe r that you recorded in S tep 3, su b- step 3.
CT87A,B,J ROUND® THERMOSTAT 1 1 69-0274 -6 Check cooling IMPORT ANT : T o a void damaging the compressor in the air conditioner , do not operate the cooling system when the outdoor temp erature is below 50°F (10°C). 1. If your CT87 has a subbase, set the System switch on the left to Cool.
CT87A,B,J ROUND® THERMOSTAT 69-0274-6 G .H. Rev . 08-02 www .honeywell.com/yourhome Automation and Control Solutions Honeywell Honeywell Limi ted-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 Printed in U.
デバイスHoneywell CT87Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Honeywell CT87Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoneywell CT87Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Honeywell CT87Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Honeywell CT87Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Honeywell CT87Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoneywell CT87Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Honeywell CT87Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoneywell CT87Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。