1 69-1431 OWNER’S GUIDE T8000C, T8001C, T801 1R, T8024C Programmable Thermostats 69-1431.
69-1431 2 Welcome to the world of comfort and energy savings with your new Honeywell programmable thermostat. Y our new programmable thermostat is designed to provide you with reliable, precise temperature control.
3 69-1431 Contents Features ....................................................................................................................... ................... 2 Key Locations and Descriptions ..................................................
69-1431 4 Key Locations and Descriptions S Y S T E M C o o l O f f H e a t A u t o O n F A N M14673 H o l d S e l e c t HOLD KEY • SET TEMPORARY TEMPERATURE HOLD. INCREASE ▲ KEY • PROGRAM TIME AND TEMPERATURE. • SET INDEFINITE TEMPERATURE HOLD.
5 69-1431 Planning Program Schedule The thermostat display shows day , time, program period, and temperature. The thermostat can be set for f our time periods per day f or w eekda ys and w eek end. Before programming the thermostat, you can use the program schedule to plan your program.
69-1431 6 Program Schedule W eekday Start Time Heating T emperature Cooling T emperature W ake ________ ________ ________ Leave ________ ________ ________ Return ________ ________ ________ Sleep _____.
7 69-1431 Programming Thermostat The thermostat is flexible and can be program- med for different schedules for weekdays and the weekend to meet your lifestyle needs. Use the personal Program Schedule for planning your time and temperature settings for various times of the day .
69-1431 8 Sleep is the time period you can set for an energy-saving temperature while you are sleeping. (For more comfortable sleep- ing, some people choose not to raise the cool temperature during the night.) IMPORT ANT Alwa ys press the k eys with y our finger tip or similar blunt tool.
9 69-1431 Setting Weekday Program Slide the SYSTEM switch to the position, Heat or Cool, you want to program. A flame (heat- ing) or a snowflake (cooling) appears in the right side of the display , when setting the program temperature. 3. Wa k e a. Press Select.
69-1431 10 b. Press Select. Press ▲ or ▼ to set Return temp- erature. 6. Sleep a. Press Select. Press ▲ or ▼ to set Sleep time. b . Press Select. Press ▲ or ▼ to set Sleep temp- erature. Setting Weekend Program 7. W ake a. Press Select. Press ▲ or ▼ to set Wa k e time.
11 69-1431 8. Leave a. Press Select. Press ▲ or ▼ to set Leave time. b . Press Select. Press ▲ or ▼ to set Leave temp- erature. 9. Return a. Press Select. Press ▲ or ▼ to set Return time. b. Press Select. Press ▲ or ▼ to set Return temp- erature.
69-1431 12 11 . Press Select. End is displayed. Program- ming is complete. The thermostat reverts to displaying the current day time and temperature in five seconds. Setting T emporary T emperature Hold 1. Press ▲ or ▼ key to set a temporary temperature setting.
13 69-1431 Operating Thermostat Setting SYSTEM and FAN Switches Use the SYSTEM and F AN switches to control thermostat operation. SYSTEM settings: Cool: The thermostat controls the cooling. Off: Both the heating and cooling are of f. Heat: The thermostat controls the heating.
69-1431 14 The minimum off-timer operates in cooling on the T8000C and T8001C, and in first stage heating or cooling on the T801 1R (heat pump model) and T8024C (multistage model). A flashing flame or or snowflake indicates the minimum off-time is in ef fect.
15 69-1431 T roubleshooting continued Symptom Ac t io n Display does not come on. • Check if the thermostat is mounted and latched on the wallplate — mount and latch the thermostat on the wallplate. • Check if the circuit breaker is tripped — reset the circuit breaker.
69-1431 16 T roubleshooting (Continued) . continued Symptom Ac t io n Heating does not come on. • Check if the circuit breaker is tripped — reset the circuit breaker. • Check if the fuse is blown — replace the fuse. • Check if the switch at the equipment is in the Off position — set to On position.
17 69-1431 Symptom Ac t io n System on indicator or is lit, but no warm or cool air is coming from the registers. Wait a couple minutes after seeing the flame or snowflake and then check the registers. System on indicator or is flashing. Minimum off-timer is in effect.
69-1431 18 W arranty Honeywell warrants this product, excluding battery , to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer .
19 69-1431 Honeywell ’ s sole responsibility shall be to repair or replace the product within the terms stated above. HONEY - WELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING A.
69-1431 20 69-1431 9-00 J.H. Copyright © 2000 Honeywell All Rights Reserved ® U.S. Registered T rademark Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers.
デバイスHoneywell T8000Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Honeywell T8000Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoneywell T8000Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Honeywell T8000Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Honeywell T8000Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Honeywell T8000Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoneywell T8000Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Honeywell T8000Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoneywell T8000Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。