X-XX UL INST ALLA TION INSTRUCTIONS ®U.S. Registered Trademark Copyright © 2004 Honeywell International Inc. All Rights Reserved T851 1G,R Microelectronic Heat Pump Thermostats APPLICA TION The T8511 Microelectronic Heat Pump Thermostat provides electronic control of 24 Vac two-stage heating and one-stage cooling heat pump systems.
69-0927—4 2 T851 1G,R MICROELECTRONIC HEA T PUMP THERMOST A TS Fig. 1. Typical location of thermostat. 5 FEET [1.5 METERS] YES NO NO NO M10106 Fig. 2. Mounting the wallplate. 2. Use a pencil to mark the mounting holes. See Fig. 2. 3. Remove the wallplate from the wall and drill two 3/16 inch holes in the wall (if drywall) as marked.
69-0927—4 3 T851 1G,R MICROELECTRONIC HEA T PUMP THERMOST A TS Fig. 3. Typical hookup in heat pump application. Fig. 4. Typical hookup in heat pump system with emergency heat relay. Fig. 5. Typical hookup in heat pump application with emergency heat relay and O/B terminal.
69-0927—4 4 T851 1G,R MICROELECTRONIC HEA T PUMP THERMOST A TS Fig. 10. T8511G (automatic changeover) system and fan keys location. NOTE: Always press the system and fan keys with your fingertip or similar blunt tool. Sharp instruments like a pen or pencil point can damage the keyboard.
69-0927—4 5 T851 1G,R MICROELECTRONIC HEA T PUMP THERMOST A TS INST ALLER SETUP NOTE: For most applications, the thermostat factory- settings do not need to be changed. Review the factory settings in Table 2 and if no changes are necessary, go to the Installer System-Test section.
69-0927—4 6 T851 1G,R MICROELECTRONIC HEA T PUMP THERMOST A TS Table 2. Thermostat Installer Setup Options (Continued). a T8511G is 48 ° F. Installer Setup Number (Press i key Factory-Setting Other.
69-0927—4 7 T851 1G,R MICROELECTRONIC HEA T PUMP THERMOST A TS Em HeatOffCool Auto Only Heat Cool OnAuto System Fan Room Outdoor Em Ht Temporary Setting Wait %Humid Aux Ht Remote Repl Batt M4844 INST ALLER SYSTEM-TEST Use the Installer System-Test to check the thermostat configurations and operation.
69-0927—4 8 T851 1G,R MICROELECTRONIC HEA T PUMP THERMOST A TS Table 4. Installer System-Test Options. (Continued) M6791 M4864 M4865 M4866 Thermostat Information 1. Press the Information i key to access the thermo- stat information. 2. Press the increase ▲ key to display the production date code.
69-0927—4 9 T851 1G,R MICROELECTRONIC HEA T PUMP THERMOST A TS M4867 5. Press the increase ▲ key again to display the EEPROM identification code. (Example: 222 = EEPROM ID 222) 6. Press and hold the increase ▲ and decrease ▼ keys together, until the room temperature is displayed, to exit the system-test.
69-0927—4 10 T851 1G,R MICROELECTRONIC HEA T PUMP THERMOST A TS Symptom Possible Cause Action Heating will not come on. Thermostat minimum off time is activated. Wait up to five minutes for the system to respond. (Continued) System selection is not set to Heat.
69-0927—4 11 T851 1G,R MICROELECTRONIC HEA T PUMP THERMOST A TS.
69-0927—4 12 T851 1G,R MICROELECTRONIC HEA T PUMP THERMOST A TS 69-0927—4 G.H. Rev . 04-04 www .honeywell.com/yourhome Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarorough, Ontario M1V 4Z9 Automation and Control Solutions Honeywell International Inc.
デバイスHoneywell T8511Gの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Honeywell T8511Gをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoneywell T8511Gの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Honeywell T8511Gの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Honeywell T8511Gで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Honeywell T8511Gを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoneywell T8511Gの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Honeywell T8511Gに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoneywell T8511Gデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。