® U.S. Regi stered T rademar k Copyright © 2002 Honeywe ll • • All Rights Reserved INSTALLATION INSTRUCTIONS 69-1412-1 T8624D Chronotherm ® IV Deluxe Programmable Multistage Thermostats APPLICATION The T8624D Chron otherm® IV Deluxe Prog rammable Multistage Thermostats provides electronic control of 24 V ac single-zone m ultistage systems.
T8624D CHRONOTHERM ® IV DELUXE PROGRAM MABLE MULTISTAGE THERMOSTATS 69-1412—1 2 Wallplate Installation The ther mostat can be mount ed horizontal ly on the wall or on a 2 in. x 4 in. (50.8 mm x 101.6 m m) wiring box. Position wallplate h orizontally on the wall o r on a 2 in.
T8624D CHRONOTHERM ® IV DELUXE PROGRAMMABLE MULTISTAGE THERMOSTATS 3 69-1412—1 Fig. 3. T ypi cal hookup of T8624D in a heat pump sy stem. Fig. 4. Correct wi ring technique. Mounting Thermosta t 1. Engage t abs at the top of the th ermostat and wal l- plate.
T8624D CHRONOTHERM ® IV DELUXE PROGRAM MABLE MULTISTAGE THERMOSTATS 69-1412—1 4 Fig. 6. T8624D k ey locations and descript ions. Using Thermostat Keys The thermo stat keys are use d to: • set cur.
T8624D CHRONOTHERM ® IV DELUXE PROGRAMMABLE MULTISTAGE THERMOSTATS 5 69-1412—1 INSTALLER SETUP NOTE: For most applicat ions, the therm ostat factory- settings will not ne ed to be chan ged. Review the facto ry settings in T abl e 2 and if no changes are necessary , go to the In staller System T e st section.
T8624D CHRONOTHERM ® IV DELUXE PROGRAM MABLE MULTISTAGE THERMOSTATS 69-1412—1 6 Adaptive Intelligent Recov ery™ control. 13 0 Adaptive Intelligent Recovery™ control is activa ted (system starts early so setpoint is reached by start of program per iod).
T8624D CHRONOTHERM ® IV DELUXE PROGRAMMABLE MULTISTAGE THERMOSTATS 7 69-1412—1 IMPORT A NT Review the setting s to confirm th at they match the system. Pres s Run Progra m to exit the Inst aller Setup. The thermostat ha s saved the Inst aller Setup c hanges and initia ted a reset in order to ope rate using the new setting s.
T8624D CHRONOTHERM ® IV DELUXE PROGRAM MABLE MULTISTAGE THERMOSTATS 69-1412—1 8 NOTE: If the current tim e is Daylight Savings Time, press Daylight Time until DST is displayed. 4. Press Run Prog ram. Viewing or Resetting Timer Settings When the thermo stat activates a timer, the thermostat flashes Filter un til the timer resets.
T8624D CHRONOTHERM ® IV DELUXE PROGRAMMABLE MULTISTAGE THERMOSTATS 9 69-1412—1 T able 5. In staller System T e st Option s. NOTE: Press a ny key and the disp layed number s will change. Press Time ∇ to go to the previous test and Time ∆ to go to the next te st.
T8624D CHRONOTHERM ® IV DELUXE PROGRAM MABLE MULTISTAGE THERMOSTATS 69-1412—1 1 0 THERMOSTAT INFORMATION 1. Press the Time ∆ key to access the thermostat information.
T8624D CHRONOTHERM ® IV DELUXE PROGRAMMABLE MULTISTAGE THERMOSTATS 1 1 69-141 2—1 TROUBLESHOOTING GUIDE T able 6. T roubleshooting Gu ide. Symptom Possible Ca use Action Display will not come on. Thermostat is not be ing powered. • Check for 24 V ac between R and C terminals.
69-1412—1 G .H. Rev . 12-02 www .ho neywell.com/yourhome T8624D CHRONOTHERM ® IV DELUXE PROGRAM MABLE MULTISTAGE THERMOSTATS Automation and Control Solutions Honeywell Honeywell Li mited-Honeywell .
デバイスHoneywell t8624dの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Honeywell t8624dをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoneywell t8624dの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Honeywell t8624dの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Honeywell t8624dで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Honeywell t8624dを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoneywell t8624dの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Honeywell t8624dに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoneywell t8624dデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。