HoneywellメーカーXenon 1902の使用説明書/サービス説明書
ページ先へ移動 of 24
Xenon™ 1902 Cordless Area-Imaging System Quick Start Guide.
.
1 Note: Refer to your user ’s guide for information about cleaning your device. For localized language versions of this document, go to www.honeywellaidc.com . Getting Started Turn off the computer’s power before connecting the base, then power up the computer once the base is fully connected.
2 USB Connection.
3 Ke yboard W edge Connection RS232 Serial P ort Connection.
4 RS485 Connection Reading T ec hniques The view finder projects an aiming beam that should be centered over the bar code, but it can be positioned in any direction for a good read. Hold the scanner over the bar code, pull the trigger, and center the aiming beam on the bar code.
5 The aiming beam is smal ler when the scanner is closer to the code and larger when it is farther from the code. Hold the scanner close to smaller bar codes, and farther away fr om large bar codes to get a proper read. If the bar code is highly re flective (e.
6 RS485 Interface The RS485 interface defaults to port 5B. If you have an IBM POS terminal using port 9B, scan the appropriate code below to program the terminal, then power cycle the cash register. Note: For additional RS485 interface selections, see the User’s Guide for your product at our website, www.
7 Ke yboard Country Scan the Program Keyboard Country bar code below, then scan the numeric bar code(s) from page 13 , then the Save bar code to program the keyboard for your country. As a general rule, the following characters ar e not supported by the scanner for countries other than the United States: @ | $ # { } [ ] = / ‘ < > ~.
8 Locked Link If you link a scanner to a ba se using the Locked Link Mode, other scanners are blocked from being linked if they are inadvertently plac ed into the base. If you do place a different scanner into the base, it will charge the scanner, but th e scanner will not be linked.
9 Unlinking the Scanner If the base has a scanner linked to it, that scanner must be unlinked before a new scanner can be linked. Once the previous sc anner is unlinked, it will no longer communicate with the base. Scan the Unlink Scanner bar code to unlink a scanner.
10 Streaming Presentation™ When in Streaming Pr esentation mode, the scanner leaves the scan illu mination on all the time and continuously sear ches for bar codes. Suffix If you want a carriage re turn after the bar code, scan the Add CR Suffix bar code .
11 Add Code ID Prefix to all Symbologies Scan the following bar code if you wish to add a Code ID prefix to all symbologies at once. Note: For a complete list of Code IDs, see the User’s Guide for your product at our website, www.
12 Data Format Editor Instructions The following are abbrevi ated instructions for entering a data format. For complete instructions refer to your User’s Guide, available at our website, www.honeywellaidc.com. 1. Scan the Enter Data Format symbol. 2.
13 Programming Chart 0 2 1 4 3 5 6 7.
14 A B C D E F 9 8 Save.
15 EZConfig To access additional featur es for the scanner use EZConfig, an online configuration software tool, available from our website at www.honeywellaidc.
16 Hong K ong Telephone: +852-29536436 Fax: +851-2511-3557 E-mail: aptechsupport@honeywell.com Singapore Telephone: +65-6842-7155 Fax: +65-6842-7166 E-mail: aptechsupport@honeywell.com China Telephone: +86 800 828 2803 Fax: +86-512-6762-2560 E-mail: aptechsupport@honeywell.
17 North America Telephone: (800) 782-4263 E-mail: hsmnaservice@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 Fax: (239) 263-9689 E-mail: laservice@honeywell.com Brazil Telephone: +55 (21) 3535-9100 Fax: +55 (21) 3535-9105 E-mail: brservice@honeywell.
18 Fax: +86-512-6762-2560 E-mail: apservice@honeywell.com Japan Telephone: +81-3-3839-8511 Fax: +81-3-3839-8519 E-mail: apservice@honeywell.com Online Product Service and Repair Assistance You can also access product service and repair assistance online at www.
19 This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of HII. © 2010 Honeywell International Inc.
20.
.
Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com Crdlss-NG2D-QS Rev A 3/10.
デバイスHoneywell Xenon 1902の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Honeywell Xenon 1902をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoneywell Xenon 1902の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Honeywell Xenon 1902の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Honeywell Xenon 1902で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Honeywell Xenon 1902を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoneywell Xenon 1902の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Honeywell Xenon 1902に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoneywell Xenon 1902デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。